SOFTWARE CONFIGURATION
154
MATRIX 220
Synchronized ID-NET Network Configurations
The Synchronized ID-NET network communications between Master and Slave are inter-
nally managed by the application software. A pre-configured job is loaded with the Syn-
chronized Layout Type and the correct Operating Mode for both the Master and Slaves
when either the Phase Mode or PackTrack Configuration is selected from the Internal
Network Setting feature.
1. Complete the configuration of all the application parameters (including Image Set-
tings) and save them to the Master with an application relative name and
with
the
option to
Clone Master configuration on Slaves
.
Figure 100 - Saving Synchronized Phase Mode Configuration to Master
2. Connect to each Slave reader via Ethernet (see note below), and set the Slave spe-
cific parameters.
NOTE
If necessary, Slave device photometric (Image Settings) parameters
must be configured separately through DL.CODE. This is preferably done
through each device’s Ethernet TCP/IP channel. If Slave devices are not
connected to Ethernet you must temporarily (manually) connect them
one by one to perform Image Settings.
Summary of Contents for Matrix 220
Page 1: ...Matrix 220 PRODUCT REFERENCE GUIDE Image Based Reader...
Page 18: ...GENERAL VIEW xviii MATRIX 220...
Page 102: ...ELECTRICAL CONNECTIONS 84 MATRIX 220 Figure 57 NPN External Trigger Using Matrix 220 Power...
Page 163: ...PASS THROUGH CONFIGURATIONS PRODUCT REFERENCE GUIDE 145...
Page 171: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 153...
Page 173: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 155 Open the cloned application job...
Page 211: ......