Step 6 - Device Configuration
Product Reference Guide
17
Advanced Setup
for Software Adjustable Focus Models
(Liquid Lens)
NOTE
To begin configuration, the reader must be correctly mounted at the correct
reading distance for your application so that its Field of View covers the
application reading area.
1. From the Task Area select Open Device Configuration.
2. The Open Device Configuration window opens showing the list of currently
saved configurations (jobs) saved on the device. For new devices, the only
saved job is the Default configuration. Click OK. The device enters run
mode and begins acquiring images.
3. Click on the Advanced Setup button and press the Play icon.
4. Place the Grade A Barcode Test Chart in the reading area. Once positioned,
stop image acquisition by clicking on the Pause button.
For Manual Adjustable Focus models go to page 24 then continue the configuration
with the "
.