Proximity Sensor on
Input 2
Ext. Trigger
EXTENDING DOF WITH AUTOMATIC IMAGE SETTINGS SELECTION SEQUENCE (INPUT SELECT) FOR LIQUID LENS MODELS
PRODUCT REFERENCE GUIDE
109
Figure 81 - Example Extending DOF Using External Image Settings Selection
Since many factors and parameters contribute to maximizing the reading process, it is
suggested to use the DL.CODE Image Auto-Setup and Focus Autolearn tools to set the
different acquisitions settings.
Multi Image Acquisition Settings Procedure using External Image Settings Selection:
1. Using the DL.CODE Image Auto-Setup and Focus Autolearn tools, set the first
acquisition setting (default) for the 195 mm Reading Distance. Then
Save on
Device
.
2. Add another Image Setting, and using the DL.CODE Image Auto-Setup and Focus
Autolearn tools, set the second acquisition setting for the 300 mm Reading Dis-
tance. Then
Save on Device
.
3. On the Reading Phase step > General Settings > Acquisition Settings, set the
Image
Settings Selection
to
External
.
4. You will now see the Sequences appear in the DL.CODE display area. Click on the
sequence with
Image Settings #1
and select the
Input 2
Activation Event to
High
.
Then
Save on Device
.
5. Verify that the reader decodes at both distances with the DL.CODE Monitor.
NOTE
The Acquisition Sequences (and therefore Image Settings) can alterna-
tively be preselected by a string from an available communication chan-
nel instead of a digital input. In any case the activation event is exclusive
(only one).
Summary of Contents for Matrix 320
Page 1: ...Matrix 320 PRODUCT REFERENCE GUIDE Image Based Industrial Reader...
Page 88: ...CBX ELECTRICAL CONNECTIONS 74 MATRIX 320 Figure 54 NPN External Trigger Using Matrix 320 Power...
Page 133: ...Reader 2 Reader 3 PASS THROUGH CONFIGURATIONS PRODUCT REFERENCE GUIDE 119...
Page 141: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 127...
Page 143: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 129 Open the cloned application job...