BM150 DISPLAY MODULE CONFIGURATION AND MESSAGES
PRODUCT REFERENCE GUIDE
147
Standard Reading Results
A = reading result – Good Read, Partial Read, Multiple Read
X = code content
Y = number of codes read
Reading Mask Only (Master Only)
X = code content (or "No Read" or "Multiple Read")
Y = Good Read, No Read, Multiple Read and Partial Read counters on the last 100 codes
read (%)
S = Reading Mask for Stand Alone or Master plus Slave readers 1 - 15
(0 = No Read, 1 = Good Read, M = Multiple Read)
T = Reading Mask for Slave readers 16 - 31
(0 = No Read, 1 = Good Read, M = Multiple Read)
Reading Mask/Device State (Master Only)
X = Recognized code label data (or "No Read" or "Multiple Read")
Y = Phase Counter (range: 0000000 to 9999999)
Z = Good Read or Multiple Read counters (%)
S = Reading Mask for Stand Alone or Master plus Slave readers 1 - 15
(0 = No Read, 1 = Good Read, M = Multiple Read)
U = Diagnostic condition for Stand Alone or Master plus Slave readers 1 - 15:
*
= reader OK
-
= reader not detected at startup
?
= reader detected at startup but not responding to diagnostic polling
!
= reader diagnostic error
Summary of Contents for Matrix 320
Page 1: ...Matrix 320 PRODUCT REFERENCE GUIDE Image Based Industrial Reader...
Page 88: ...CBX ELECTRICAL CONNECTIONS 74 MATRIX 320 Figure 54 NPN External Trigger Using Matrix 320 Power...
Page 133: ...Reader 2 Reader 3 PASS THROUGH CONFIGURATIONS PRODUCT REFERENCE GUIDE 119...
Page 141: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 127...
Page 143: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 129 Open the cloned application job...