STEP 4 - X-PRESS CONFIGURATION
PRODUCT REFERENCE GUIDE
5
STEP 4 - X-PRESS CONFIGURATION
Once Matrix 320 has calibrated image density, you can configure it for optimal code
reading relative to your application. This configuration can be performed either through
the X-PRESS Interface or the DL.CODE configuration program.
Aim
Figure 7 - X-PRESS Interface: Aim Function
1. Enter the Focus function by pressing and holding the X-PRESS push button until
the Focus LED is on.
2. Release the button to enter the Focus function.
3.
Select a code from your application
. Position the code at the center of the FOV.
4. Exit the Focus function by pressing the X-PRESS push button once.
Setup
Figure 8 - X-PRESS Interface: Setup Function
5. Enter the Setup function by pressing and holding the X-PRESS push button until
the Setup LED is on.
6. Release the button to enter the Setup function. The Setup LED will blink until the
procedure is completed.
The Setup procedure ends when the Image Acquisition parameters are successfully
saved in the reader memory, the Setup LED will stop blinking and Matrix 320 emits
3 high pitched beeps.
If the calibration cannot be reached after a timeout of about 5 (five) seconds
Matrix 320 will exit without saving the parameters to memory, the Setup LED will
stop blinking and in this case Matrix 320 emits a long low pitched beep.
You can exit the Aim/Autofocus function at any time by pressing the
X-PRESS push button once. After a short delay the Autofocus procedure
is canceled and the laser pointer turns off.
Summary of Contents for Matrix 320
Page 1: ...Matrix 320 PRODUCT REFERENCE GUIDE Image Based Industrial Reader...
Page 88: ...CBX ELECTRICAL CONNECTIONS 74 MATRIX 320 Figure 54 NPN External Trigger Using Matrix 320 Power...
Page 133: ...Reader 2 Reader 3 PASS THROUGH CONFIGURATIONS PRODUCT REFERENCE GUIDE 119...
Page 141: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 127...
Page 143: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 129 Open the cloned application job...