SOFTWARE CONFIGURATION
120
MATRIX 320
INTERNAL NETWORK CONFIGURATIONS
Internal Network configurations (also called Master/Slave configurations), are designed
to collect data from several devices connected together in an ID-NET™ network and
send data output to the Host system.
DL.CODE has a Net Autoset feature for the Internal ID-NET Network which automatically
recognizes and assigns addresses to all connected Slave readers.
In order to automatically recognize the ID-NET Slaves, all devices must be physically
installed and electrically connected (including ID-NET network wiring).
The general procedure (also detailed in the following paragraphs) is to:
1. Mount all the readers mechanically (refer to "
Mechanical Dimensions" on page 50
and "
Mounting And Positioning Matrix 320" on page 54
) and electrically (refer to "
) with factory default settings (Layout Type = Alone, Inter-
nal Network Role = Slave).
2. Run DL.CODE and verify that all the devices are discovered and shown in the
device list area.
3. Connect to the designated Master device in DL.CODE and open the
Setup Internal
Network Configuration
. You will be prompted to change the device to Master.
Click OK. The Slave units will automatically be recognized. See "
.
4. Depending on the application, select Set Default Multidata Configuration or Set
Default Synchronized Phase Mode Configuration.
5. Connect to each Slave reader via Ethernet and set the Slave specific parameters
depending on the application type. Save each Slave specific configuration. See
"
Multidata ID-NET Network Configurations" on page 123
Network Configurations" on page 128
.
6. For Synchronized networks Verify/Test network performance. See "
Slave Synchronized Configuration" on page 132
.
7. Perform the
Backup current Internal Network configurations
procedure. See
.
Summary of Contents for Matrix 320
Page 1: ...Matrix 320 PRODUCT REFERENCE GUIDE Image Based Industrial Reader...
Page 88: ...CBX ELECTRICAL CONNECTIONS 74 MATRIX 320 Figure 54 NPN External Trigger Using Matrix 320 Power...
Page 133: ...Reader 2 Reader 3 PASS THROUGH CONFIGURATIONS PRODUCT REFERENCE GUIDE 119...
Page 141: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 127...
Page 143: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 129 Open the cloned application job...