INTERNAL NETWORK CONFIGURATIONS
PRODUCT REFERENCE GUIDE
123
Multidata ID-NET Network Configurations
The Multidata ID-NET network communications between Master and Slave are man-
aged by the application job (configuration) using the pass-through feature. A pre-config-
ured job is loaded with the correct pass-through settings for both the Master and Slaves
when the Default Multidata Configuration is selected from the Internal Network Setting
feature.
1. Complete the configuration of all the application parameters (including Image Set-
tings) and save them to the Master with an application specific name.
Optionally, checking the
Save on Slave Device
box can be helpful to save all the current
individual Slave configurations with the new configuration
name
. This does not clone
any parameters. If not checked, Slave configurations will remain as
Temp
configurations
and you will be warned that changes to the Master have not been saved to the Cluster.
For Multidata configurations, the option to
Clone Master configuration on Slaves
must
not be checked
.
Figure 83 - Saving Multidata Configuration to Master
The jobs must not be cloned because the Master and Slaves have different input/output
communication channels. The readers are also working independently from each other,
often on separate stations with different code reading requirements, different operating
modes, etc.
2. Connect to each Slave reader via Ethernet (see note below), and set all the config-
uration parameters of each Slave device.
NOTE
If necessary, Slave device photometric (Image Settings) parameters
must be configured separately through DL.CODE. This is preferably done
through each device’s Ethernet TCP/IP channel. If Slave devices are not
connected to Ethernet you must temporarily (manually) connect them
one by one to perform Image Settings.
Summary of Contents for Matrix 320
Page 1: ...Matrix 320 PRODUCT REFERENCE GUIDE Image Based Industrial Reader...
Page 88: ...CBX ELECTRICAL CONNECTIONS 74 MATRIX 320 Figure 54 NPN External Trigger Using Matrix 320 Power...
Page 133: ...Reader 2 Reader 3 PASS THROUGH CONFIGURATIONS PRODUCT REFERENCE GUIDE 119...
Page 141: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 127...
Page 143: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 129 Open the cloned application job...