MATRIX 400™ REFERENCE MANUAL
106
8
8.4 CONFIGURATION
Once connected to Matrix 400™ as described in par. 8.3, you can modify the configuration
parameters as follows:
1.
Press the Calibration Tool button from the Main Menu. Matrix 400™ will download its
permanent memory configuration parameters with the default values (if it is the first time)
to VisiSet™. The Calibration Tool window will be displayed together with the Parameter
Setup window working in Interactive Mode (see par. 8.4.1 and par. 8.4.3).
2.
Edit the Matrix 400™ configuration parameters according to your application
requirements.
3.
Use the
Calibration Tool
to fine tune the reading performance. See par. 8.4.3.
4.
Close the Calibration Tool window and disable the Interactive Mode by pressing the
interactive button.
5.
Save the new configuration to the reader permanent memory by pressing the Send
button.
6.
Close the Parameter Setup window and press
Disconnect
on the VisiSet™ menu bar
(see Figure 113) or launch
Run
Mode from the VisiSet™ Main menu.
Disconnect
exits closing communication between Matrix 400™ and VisiSet™, and
causes Matrix 400™ to enter Run Mode. The disconnected reader serial port is now
available.
Run
command does not close communication between Matrix 400™ and VisiSet™,
and causes Matrix 400™ to enter Run Mode. In this case the reader output messages
are displayed on the VisiSet™ terminal and the statistics are displayed in the
Statistics window (Statistics enabled).