TECHNICAL FEATURES 

 

ELECTRICAL FEATURES 

Power  

Supply Voltage

 

10 to 30 Vdc

 

Power Consumption

 

8 W max.; 5 W typical

 

Communication Interfaces 

 

Main 
 - RS232 
 - RS485 full-duplex 
 - RS485 half-duplex 
Auxiliary - RS232 
Ethernet (Ethernet Models only)

 

 
2400 to 115200 bit/s 
2400 to 115200 bit/s 
2400 to 115200 bit/s 
2400 to 115200 bit/s 
10/100 Mbit/s

 

Inputs 

External Trigger and IN2 

Opto-coupled and polarity insensitive

 

Outputs 

OUT1 and OUT2 

Opto-coupled

 

OPTICAL FEATURES 

400-4xx-xxx models 

400-6xx-xxx models 

Image Sensor 

CMOS 

CCD 

Image Format 

SXGA (1280x1024) 

UXGA (1600x1200) 

Frame Rate 

27 frames/sec. 15 

frames/sec. 

Pitch 

±

 35° 

Tilt 

0° - 360° 

Lighting System

 

Internal or External Illuminator (accessories)

 

LED Safety Class 

Class 1 to EN60825-1 

USER INTERFACE 

LED Indicators

 

Power, Ready, Good; Trigger; Com, Status, (Network); (Green Spot)

 

Keypad Button 

Configurable via VisiSet™ 

SOFTWARE FEATURES 

Readable Code Symbologies 

1-D and stacked

 

2-D

 

POSTAL

 

• 

PDF417 Standard and Micro PDF417 

• 

Code 128 (EAN 128) 

• 

Data Matrix ECC 200 
(Standard and Direct Marking) 

• 

Australia Post 

• 

Royal Mail 4 State Customer 

• 

Code 39 (Standard and Full ASCII) 

• 

Interleaved 2 of 5 

• 

QR Code 
(Standard and Direct Marking) 

• 

Kix Code 

• 

Japan Post 

• 

Codabar 

• 

MAXICODE 

• 

PLANET 

• 

Code 93 

• 

Aztec Code 

• 

POSTNET, POSTNET (+BB) 

• 

Pharmacode 

• 

EAN-8/13 - UPC-A/E 
(including Addon 2 and Addon 5) 

• 

GS1 DataBar (RSS) Family 

• 

Composite Symbologies 

• 

Microglyph 
(this symbology requires an 
activation procedure – contact your 
local Datalogic Automation 
distributor for details) 

• 

P PLANET, 
POSTNET (+BB) + PLANET 

Operating Mode 

O

NE 

S

HOT

, C

ONTINUOUS

, P

HASE 

M

ODE

 

Configuration Methods 

By means of X-PRESS™ Human Machine Interface or VisiSet™ configuration 
software 

Parameter Storage 

Permanent memory (Flash) 

CODE QUALITY VERIFICATION 

Standard Supported 

Symbologies 

ISO/IEC 16022 

Data Matrix ECC 200 

ISO/IEC 18004 

QR Code 

ISO/IEC 15415 

Data Matrix ECC 200, QR Code 

ISO/IEC 15416 

Code 128, Code 39, Interleaved 2 of 5, Codabar, Code 93, EAN-8/13, UPC-A/E 

AS9132A 

Data Matrix ECC 200 

MECHANICAL FEATURES 

Dimensions 

123 x 60.5 x 87 mm (4.85 x 2.38 x 3.43 in.) with lens cover 

Weight 

482 g. (17 oz.) with lens and internal illuminator 

Material Aluminium 

ENVIRONMENTAL FEATURES 

Operating Temperature 

0 to 50 

°

C (32 to 122 °F) 

Storage Temperature 

-20 to 70 

°

C (-4 to 158 °F) 

Max. Humidity 

90% non condensing 

Protection Class 

IP67 

Summary of Contents for Matrix 400

Page 1: ...al Illuminator separate accessory Ethernet Connection LED Ethernet Models Only 11 NOTE This manual illustrates a Stand Alone application For other types of installations such as Pass Through Multiplex...

Page 2: ...com E En Internet est n disponibles las versiones actualizadas de los drivers y documentaci n de este producto Direcci n Internet www automation datalogic com SERVICES AND SUPPORT Datalogic provides...

Page 3: ...4 internal illuminator spacers into the holes provided on the base b Align and mount the Illuminator board tightly onto the spacers using the 4 screws provided in the illuminator package The spacers a...

Page 4: ...inout when the Matrix 400 reader is connected by means of the C BOX 100 C BOX 100 Terminal Block Connectors Power Outputs 1 3 5 VS 21 OUT 1 2 4 6 GND 22 OUT 1 7 8 EARTH GROUND 23 OUT 2 20 40 Reserved...

Page 5: ...cket Back Figure 4 Positioning with Mounting Bracket Side 2 When mounting the Matrix 400 take into consideration these three ideal label position angles Pitch or Skew 10 to 20 and Tilt 0 although the...

Page 6: ...ction The Blue Diamonds turn on The procedure is as follows a Adjust the Focus ring towards the Near position until the Blue Diamonds are perfectly in focus see Figure 7 At long focal distances a skew...

Page 7: ...ion parameters are successfully saved in the reader memory the Setup LED will remain on continuously and Matrix 400 emits 3 high pitched beeps If the calibration cannot be reached after a timeout of a...

Page 8: ...igh pitched beeps If the calibration cannot be reached after a timeout of about 5 five seconds Matrix 400 will exit without saving the parameters to memory the Setup LED will not remain on continuousl...

Page 9: ...l VisiSet turn on the PC that will be used for the configuration running Windows 98 2000 NT or XP then insert the VisiSet CD ROM wait for the CD to autorun and follow the installation procedure This c...

Page 10: ...s Quick Reference Guide 3 Press the Positioning button The reader continuously acquires images and gives visual feedback in the view image window to indicate when the code is centered with respect to...

Page 11: ...sult section of the Autolearning Wizard window shows the parameter settings and the code type results 6 Select a Saving Options choice and press the Save button 7 Close the AutoLearning Wizard NOTE If...

Page 12: ...ion Once entered the Bar Graph on the five LEDs is activated and if the reader starts reading codes the Bar Graph shows the Good Read Rate In case of no read condition only the STATUS LED is on and bl...

Page 13: ...rameter Setup window in off line mode Advanced configuration is addressed to expert users being able to complete a detailed reader configuration The desired parameters can be defined in the various fo...

Page 14: ...ng unknown codes In normal operating mode the colors and meaning of the five LEDs are illustrated in the following table READY green This LED indicates the device is ready to operate GOOD green This L...

Page 15: ...5 500 LT 006 LNS 1006 6mm 59 5 46 5 71 85 LT 002 LNS 1109 9mm 40 5 31 49 5 85 LT 002 LNS 1112 12 5mm 31 23 5 38 85 LT 002 LNS 1116 16mm 24 18 30 85 LT 001 LNS 1125 25mm 15 11 5 19 135 LT 001 LNS 1135...

Page 16: ...Post Royal Mail 4 State Customer Code 39 Standard and Full ASCII Interleaved 2 of 5 QR Code Standard and Direct Marking Kix Code Japan Post Codabar MAXICODE PLANET Code 93 Aztec Code POSTNET POSTNET...

Page 17: ...40 Figure 19 Matrix 400 Overall Dimensions 4 0 16 M4 0 16 N 5 4 3 0 17 50 1 97 61 2 40 72 5 2 85 83 5 3 29 12 5 0 49 12 5 0 49 12 5 0 49 12 5 0 49 40 1 57 3 0 12 50 1 97 70 2 76 4 2 0 17 8 5 0 3 3 4...

Page 18: ...ted 10 to 30 V minimum 1 A CE COMPLIANCE Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate m...

Page 19: ...Lieferanten ber den sie das Produkt erworben haben oder besuchen sie unsere Hompage unter www automation datalogic com FRAN AIS Information aux utilisateurs concernant la Directive Europ enne 2002 96...

Page 20: ...MATRIX 400 QUICK GUIDE 20 SERIAL NUMBER REFERENCES Place the replicate Matrix 400 base lens and illuminator serial number labels here for reference Serial Numbers Matrix 400 Lens Illuminator 821001350...

Reviews: