MATRIX 450™ REFERENCE MANUAL
104
6
6.4.5 M/S
Synchronized
and
Multidata Fieldbus Host
Alternatively, the Master reader can communicate to the Host as a Slave node on a Fieldbus
network. This requires using an accessory Fieldbus interface board installed inside the
CBX500 connection box.
System configuration can be accomplished through the Auxiliary interface of each individual
reader (internal CBX500 9-pin connector) using the VisiSet™ configuration program or Host
Mode programming. See par. 2.3.1 for details.
Figure 96 – ID-NET™ Fieldbus M/S Synchronized Layout
Figure 97 – ID-NET™ Fieldbus M/S Multidata
Fieldbus Interface
External Trigger (for One Shot or Phase Mode)
ID-NET™ (up to 16 devices - practical limit)
Host
2
Master
Slave#1
Slave#n
Power
1
3
Fieldbus Interface
Auxiliary Serial Interface (Local Echo) (RS232)
External Trigger (for One Shot or Phase Mode)
ID-NET™ (up to 32 devices, max network extension of 1000 m)
Host
1
4
3
2
Master Slave#1
Slave#n
Power