MATRIX 450™ REFERENCE MANUAL
124
8
Parameters to verify/modify:
Operating Mode
Sets the parameters which customize the reader operating mode
starting from three main modes:
One Shot: acquires a single image based on the selected value
for the Acquisition Trigger and Acquisition Trigger Delay.
Continuous: continuously acquires images with a rate up to the
maximum allowable frame rate per second for the given sensor
depending on the decoding time and the Region of Interest
settings.
Phase Mode: acquires images during the reading phase
depending on the selected value for the Acquisition Trigger and
Acquisition Trigger Delay. The Reading Phase-ON and Reading
Phase-OFF events mark respectively the beginning and end of
the reading phase.
Calibration
Calibrates the acquisition parameters to maximize the reading
performance (see par. 8.4.3).
Communication
Configures the parameters relative to each serial port regarding
the transmission, message formatting and string receiving.
Any change to the VisiSet™ communication port parameters
(baud rate, data bits, etc.) is effective as soon as the reader is
disconnected from VisiSet™.
Reading System Layout
Allows configuring the device according to the desired layout:
Standalone, ID-NET™ or Master/Slave RS232
WebSentinel
Enables the Ethernet WebSentinel Agent for communication with
the Datalogic WebSentinel™ plant array monitor.
Ethernet
Sets the parameters related to the on board Ethernet interface
and to its communication channels.
CBX Gateway
Sets the parameters related to the External Host Interface
Module through the CBX500 and to its communication channels.
Image Processing
Sets the image processing parameters shared by all available
symbologies.
1D & 2D, Postal Codes
Sets the characteristics of the code symbologies to be read.
Data Collection
Defines the code-collection parameters and the output message
format.
Digital I/O
Configures the reader input/output parameters.
Match Code
Allows setting a user-defined code and relative parameters to
which the read code will be compared (matched).
Miscellaneous
Sets the reader name and the saved image format.
Symbol Verification
Sets the parameters relative to the various specifications in the
Standards which regulate code validation.
LEDs And Keypad
Sets the X-PRESS™ LED and Keypad parameters related to their
selected Functions: Beeper, Green Spot, Setup, Positioning, etc.
Display
Sets the Display language and Layout of the BM150 Display
when using the CBX500 connection box.
Diagnostics
Enables various diagnostic messages, formatting and actions.
Summary of Contents for Matrix 450
Page 1: ...MATRIX 450 Reference Manual...
Page 12: ...xii...
Page 160: ...www automation datalogic com...