RAPID CONFIGURATION
9
1
Setup
5. Enter the Setup function by pressing and holding the X-PRESS™ push button until the
Setup LED is on.
Figure 8 – X-PRESS™ Interface: Setup Function
6. Release the button to enter the Setup function. The Setup LED will blink until the
procedure is completed.
The Setup procedure ends when the Image Acquisition parameters are successfully saved
in the reader memory, the Setup LED will remain on continuously and Matrix 450™ emits
3 high pitched beeps.
If the calibration cannot be reached after a timeout of about 5 (five) seconds Matrix 450™
will exit without saving the parameters to memory, the Setup LED will not remain on
continuously but it will just stop blinking. In this case Matrix 450™ emits a long low pitched
beep.
7. Exit the Setup function by pressing the X-PRESS™ push button once.
Learn
8. Enter the Learn function by pressing and holding the X-PRESS™ push button until the
Learn LED is on.
Figure 9 – X-PRESS™ Interface: Learn Function
9. Release the button to enter the Learn function. The Learn LED will blink until the
procedure is completed.
The Learn procedure ends when the Image Density value is successfully saved in the
reader memory, the Learn LED will remain on continuously, the Green Spot is activated
and Matrix 450™ emits 3 high pitched beeps.
If the calibration cannot be reached after a timeout of about 3 (three) minutes Matrix 450™
will exit without saving the parameters to memory, the Learn LED will not remain on
continuously but it will just stop blinking. In this case Matrix 450™ emits a long low pitched
beep.
10. Exit the Learn function by pressing the X-PRESS™ push button once.
READY
SETUP
FOCUS
TEST
LEARN
GOOD
TRIGGER
COM
STATUS
red yellow yellow green green
READY
SETUP
FOCUS
TEST
LEARN
GOOD
TRIGGER
COM
STATUS
red yellow yellow green green
Summary of Contents for Matrix 450
Page 1: ...MATRIX 450 Reference Manual...
Page 12: ...xii...
Page 160: ...www automation datalogic com...