MATRIX 450™ REFERENCE MANUAL
36
2
Test Mode (Function 1)
Once entered, the Bar Graph on the five LEDs is activated and if the imager starts reading
codes the Bar-Graph shows the Good Read Rate. In case of a NO READ condition, only the
Status
LED is on and blinks.
The Bar Graph has the following meaning:
To exit the Test Mode, press the X-PRESS™ push button once.
NOTE
By default, the Test exits automatically after three minutes.
Focus/Locate (Function 2)
This function causes the Blue Diamonds™ to turn on. The Blue Diamonds™ can be used to
focus the lens at the desired reading distance and since they are centered on the FOV they
can also be used to position the imager on the code. The Focus LED blinks to indicate this
state.
To exit the Focus/Locate Mode, press the X-PRESS™ push button once. The Blue
Diamonds™ turn off.
Setup (Function 3)
Once entered, the imager automatically performs Image Acquisition parameter calibration for
the specific code presented to it.
The Setup LED will blink until the procedure is completed.
The Setup procedure ends when the Image Acquisition parameters are successfully saved in
the reader memory, the Setup LED will remain on continuously and Matrix 450™ emits 3 high
pitched beeps.
If the calibration cannot be reached after a timeout of about 5 (five) seconds Matrix 450™ will
exit without saving the parameters to memory, the Setup LED will not remain on continuously
but it will just stop blinking. In this case Matrix 450™ emits a long low pitched beep.
READY
SETUP
FOCUS
TEST
LEARN
GOOD
TRIGGER
COM
STATUS
20%
40%
60%
75%
95%