4.7 EXTERNAL ILLUMINATORS
If an External Illuminator is used, it can be powered from the CBX connection box. It must be
connected to the
Vdc
and
GND
terminal clamps.
CAUTION
Power is available directly to the Illuminator, independently from the Power
Supply Switch inside the CBX.
In the case of the LT-300 illuminators, one of the available digital outputs must be connected
as the control signal. In VisiSet™, configure the Output Line Function parameter to "External
Lighting System" and the Matrix Output
x
External Lighting System Mode parameter to
"Triggered".
Control Signal for
LT-300 illuminators
Power to External
Illuminator
Figure 51 – External Lighting System Connections
Below is a table summarizing the External Illuminator wiring and power requirements.
Illuminator
Wire Color
CBX/Matrix Signal
Meaning
LT-300
Brown
Vdc
10 to 30 Vdc
Black
GND
Ground
Yellow/Green
Earth
Shield/Earth
Ground
Blue
O1- or O2-
Control Signal -
White
O1+ or O2+
Control
The LT-300 Ring Lighting System is designed for reading codes produced by Dot Peening or
Laser Etching on flat, reflective parts. Applications using this illuminator with Matrix 450™
could require alternative mounting solutions to be provided by the customer.
Figure 52 - LT-300 Ring Lighting System