CBX ELECTRICAL CONNECTIONS
53
4
The RTS and CTS signals control data transmission and synchronize the connected devices.
START
OF
TRANSMISSION
END
OF
TRANSMISSION
+ V
RTS
- V
+ V
TX DATA
- V
+ V
CTS
- V
DATA
TRANSMISSION
DATA
TRANSMISSION
C1 C2
C4
C3
C5
TRANSMISSION
STOPPED
ENABLED
DISABLED
ENABLED
IDLE
IDLE
Figure 30 - RS232 Control Signals
If the RTS/CTS handshaking protocol is enabled, the Matrix 450™ activates the RTS output
to indicate a message is to be transmitted. The receiving unit activates the CTS input to
enable the transmission.
4.2.2 RS485
Full-Duplex
Interface
The RS485 full-duplex (5 wires + shield) interface is used for non-polled communication
protocols in point-to-point connections over longer distances (max 1200 m / 3940 ft) than
those acceptable for RS232 communications or in electrically noisy environments.
The CBX pinout follows:
CBX100/500
Function
TX+
RS485 Transmit Data +
RX+
RS485 Receive Data +
TX-
RS485 Transmit Data -
RX-
RS485 Receive Data -
SGND Signal
Ground
RX485+
TX485+
SGND RX485- TX485-
USER INTERFACE
SGND TX+
RX+
TX- RX-
READER
Figure 31 - RS485 Full-duplex Connections
Summary of Contents for Matrix 450
Page 1: ...MATRIX 450 Reference Manual...
Page 12: ...xii...
Page 160: ...www automation datalogic com...