STEP 5
– CALIBRATE IMAGE DENSITY
In order to function correctly to the fullest extent of its capabilities, Matrix 450N must acquire
information regarding image density or PPI (pixels per inch). This calibration takes place
through the X-PRESS Interface and the
Focusing and PPI Setup Chart
included in the
package. This procedure is necessary for the first time installation, if the lens type is changed
or if the focal distance is changed.
Locate
1. Enter the Focus function by pressing and holding the
X-PRESS push button until the Focus LED is on.
2. Release the button to enter the Focus function. The
Blue Diamonds and laser pointers turn on.
Figure 10
– X-PRESS™ Interface:
Locate Function
3. From the
Focusing and PPI Setup Chart
, position the 1 mm code at the center of the
Horizontal FOV (aligned with the laser pointers).
Figure 11
–Aligning the Focusing and PPI Setup Chart Using Laser Pointers as Reference
4. Exit the Focus function by pressing the X-PRESS push button once. The Blue Diamonds
and laser pointers turn off.