background image

MATRIX 450N™ REFERENCE MANUAL 

 

32 

 

 

Standard Application Program 

A  Standard  Application  Program  is  factory-loaded  onto  Matrix  450N.  This  program  controls 
code reading, data formatting, serial port and Ethernet interfacing, and many other operating 
and  control  parameters.  It  is  completely  user  configurable  from  a  Laptop  or  PC  using  the 
dedicated configuration software program DL.CODE™, provided on the DL.CODE mini-DVD 
(downloaded zip file or mini-DVD accessory). 
 
There  are  different  programmable  operating  modes  to  suit  various  code  reading  system 
requirements. 
 
Quick,  automatic  focus,  positioning,  calibration  and  code  setting  of  the  imager  can  be 
accomplished  using  the  X-PRESS  button  and  LEDs  on  top  of  the  reader  without  the 
necessity of a PC. 
 
The  previous  functions  can  also  be  performed  through  DL.CODE.  This  tool  includes  visual 
feedback from the reader. 
 
DL.CODE  provides  a  Calibration  Tool  to  verify  the  exact  positioning  of  the  reader  and  to 
maximize its reading performance. 
 
Statistics on the reading performance can also be visualized through the Monitor window in 
DL.CODE. 
 
 

Excellent Performance 

  5.0 MPixels 

  Adjustable focus through C-Mount lenses 

  Powerful Illuminator Lighting Systems 

  Outstanding decoding capability on 1D, 2D, Stacked, Postal symbologies 

  Omni-directional reading 

  Frame Rate up to 15 frames/sec 

  Image Cropping for higher frame rate 

  Up to 100 readable codes in a single frame 

 
 

Ease of Setup 

  Quick installation without PC by using X-PRESS interface for easy and intuitive setup 

  Blue Diamonds aiming and focusing system 

  Automatic Imager calibration and Code Settings 

  Calibration Tool to verify exact code positioning in the Field of View and to maximize the 

reading performance 

  Windows-based  DL.CODE  software  to  configure  the  reader  parameters  via  PC  Ethernet 

interface 

  User-defined database of Image Acquisition Settings (parameter sets) 

 
 
 

Summary of Contents for matrix 450N

Page 1: ...REFERENCE MANUAL Matrix 450N...

Page 2: ...from Datalogic S p A Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S and the E U Matrix 450N ID NET DL CODE X PRESS and Blue Diamonds...

Page 3: ...Density 10 Step 6 X PRESS Configuration 12 Step 7 Installing DL CODE Configuration Program 15 Step 8 Device Configuration 18 Step 9 Test Mode 29 Advanced Reader Configuration 30 2 INTRODUCTION 31 2 1...

Page 4: ...rial Host 76 5 TYPICAL LAYOUTS 77 5 1 Ethernet Connection 77 5 2 Serial Connection 79 5 3 Fieldbus Connection 80 5 4 Pass Through 81 5 5 ID NET Multidata Network Pass Through 82 5 6 ID NET Synchronize...

Page 5: ...CODE 140 7 9 2 Accessing the HMI Interface Through Keypad and Display Menu 140 7 9 3 Display Messages 142 7 9 4 BM150 Backup and Restore Procedure 145 8 MAINTENANCE 146 8 1 Cleaning 146 9 TROUBLESHOOT...

Page 6: ...Accessories and Downloads including documentation software drivers and utility programs SUPPORT SERVICES INDUSTRIAL AUTOMATION Several links from the Industrial Automation list take you to additional...

Page 7: ...l 20th 2016 the main European directives applicable to Datalogic products require inclusion of an adequate analysis and assessment of the risk s This evaluation was carried out in relation to the appl...

Page 8: ...to Laser Notice N 50 date June 24 2007 This product is classified as a Class 2 laser product according to IEC 60825 1 regulations CAUTION Use of controls or adjustments or performance of procedures o...

Page 9: ...vibration and shock when correctly installed however it is also a precision product and therefore before and during installation it must be handled correctly to avoid damage avoid that the readers ar...

Page 10: ...x do not weld the reader into position which can cause electrostatic heat or reading window damage do not spray paint near the reader which can cause reading window damage NO NO...

Page 11: ...ng Labels Bracket Mounting Holes 6 Lens Cover Lens separate accessory MAC Address Label Ethernet Connector Power On LED LT 03x Lighting System separate accessory Ethernet Connection LED HMI X PRESS In...

Page 12: ...xii...

Page 13: ...cleaning 2 Remove the sensor protection label by pulling it off of the base 3 Mount the LNS 12xx lens by slowly screwing it onto the base until it arrives at the mechanical stop NOTE The lens mount is...

Page 14: ...ion gasket shown in the figure below Figure 2 Assembling Matrix 450N and LNS 12xx Lens NOTE The anti vibration components are already mounted to all Datalogic LNS 12xx Lenses Locking Knobs Lens Cover...

Page 15: ...ens 5MP with anti vibration components 93A400034 LT 032 ULTRA POWER LT NARROW BLUE 40 93ACC0034 LNS 1225 25 mm C Mount Lens 5MP with anti vibration components 93A400032 LT 030 ULTRA POWER LT SUPERNARR...

Page 16: ...x Connect the Brown White wires to Vdc and Black Blue wires to GND Connect the cable shield to Earth ground Use CAB MS0x between Matrix 450N and the CBX for Matrix 450N power external trigger device p...

Page 17: ...e Ethernet host through the Gigabit Ethernet connection CAB GE0x Figure 5 Matrix 450N in Stand Alone Layout without CBX to Ethernet Host Matrix 450N LT 03x can also be used in an ID NET Master Slave c...

Page 18: ...itive Auxiliary Interface I1B External Trigger B polarity insensitive TX Auxiliary Interface TX V Power Reference External Trigger RX Auxiliary Interface RX V Power Source Inputs SGND Auxiliary Interf...

Page 19: ...Matrix 450N body mounting bracket accessory The body mounting bracket is not designed to support the LT 03x 2 When mounting the Matrix 450N LT 03x assembly take into consideration these three ideal l...

Page 20: ...Once the lens is fully tightened to the mechanical stop Step 1 it can be rotated counterclockwise up to one full turn without loosening the lens so that the diaphragm scale and locking knobs can be ea...

Page 21: ...focus Tighten the Focus Locking Knob c Set the Diaphragm to the aperture stop F number stated in the conditions relative to the selected reading diagram and then tighten the Diaphragm Locking Knob d R...

Page 22: ...changed or if the focal distance is changed Locate 1 Enter the Focus function by pressing and holding the X PRESS push button until the Focus LED is on 2 Release the button to enter the Focus functio...

Page 23: ...SS Interface Setup Function Learn 7 Enter the Learn function by pressing and holding the X PRESS push button until the Learn LED is on 8 Release the button to enter the Learn function The Learn LED wi...

Page 24: ...it the Focus function by pressing the X PRESS push button once The Blue Diamonds and laser pointers turn off Figure 14 X PRESS Interface Locate Function Setup 5 Enter the Setup function by pressing an...

Page 25: ...s a long low pitched beep Figure 16 X PRESS Interface Learn Function NOTE The Grade A Barcode Test Chart or the Focusing and PPI Setup Chart cannot be used to set the Code 128 symbology even though th...

Page 26: ...ease and re press the button during this LED blinking sequence All the device s Environment parameters are reset including the default IP Address The Matrix 450N emits 3 high pitched beeps and after a...

Page 27: ...files maintaining the folder structure and run the start hta file to access the installation pop up Click on the Install DL CODE link to run the installation program and follow the installation proced...

Page 28: ...s 4 Find your device in the list by matching its serial number SN then click on the device wrench icon to open the Device Environment Configuration window 5 Change the Ethernet Settings IP Address Sub...

Page 29: ...RAPID CONFIGURATION 17 1 7 Double click on or drag the device icon into the Selected Device Information Area Details about the device will be displayed in this area Figure 19 DL CODE Opening Window...

Page 30: ...a select Open Device Configuration The device enters run mode and begins acquiring images 2 The Open Device Configuration window opens showing the list of currently saved configurations jobs saved on...

Page 31: ...ick the Image Setup button and then click the Image Auto Setup button to automatically acquire the best exposure time and gain values 5 Select the Static or Dynamic Self Tuning option Start Autolearn...

Page 32: ...ng multiple lighting or code reading conditions up to 10 different Image Setups can be configured by adding them with the icon For the next step you need to enable the Focus Calibration Tool from the...

Page 33: ...lick Play to enter run mode and reposition the code NOTE To enlarge the visual image of the code and the oscilloscope views you can drag the Focus Calibration window up and click on the zoom image ico...

Page 34: ...quire PPI button to automatically set Image Density so that Matrix 450N will function correctly and to the fullest extent of its capabilities This procedure is necessary for first time installations o...

Page 35: ...figuration from temporary memory to permanent memory giving it a specific name 8 Now place an application specific code in front of the reader and only click the Image Auto Setup button to register an...

Page 36: ...and moved by dragging its borders with the mouse The code must be found within this area in order to be decoded 2 Add your application specific codes to the Code Settings by selecting them from the ic...

Page 37: ...ons over the Configuration Parameters tree area Continuous One Shot Phase Mode or PackTrack 2 Configure the relative Operating Mode parameters from the Reading Phase parameters panel Different groups...

Page 38: ...d The following example shows Code Combination By default the Expected Codes when more than one code type is selected are in logical AND which means that all codes are required to be decoded to produc...

Page 39: ...ting Message s from the Configuration Parameters tree area Message 1 Message 2 etc You can add fields to the output message by clicking on the icons above the Message Field area They will be appended...

Page 40: ...gure your application specific Digital Output s and Green Spot if used from the Configuration Parameters tree area Output 1 Output 2 etc NOTE Save the configuration from temporary memory to permanent...

Page 41: ...enter the Test function Once entered the Bar Graph on the five LEDs is activated and when codes are placed in the reading area FOV the Bar Graph shows the Good Read Rate In case of no read condition o...

Page 42: ...ATION For further details on advanced product configuration refer to the DL CODE User s Guide available in the DL CODE Help menu Host Mode Programming The reader can also be partially configured from...

Page 43: ...Multiple reading attempts are generally not needed so the highest reading throughput and ease of use are always guaranteed Matrix 450N is also the perfect solution for automated identification in man...

Page 44: ...feedback from the reader DL CODE provides a Calibration Tool to verify the exact positioning of the reader and to maximize its reading performance Statistics on the reading performance can also be vi...

Page 45: ...gnostic software tools Flexible Solution Modular design Adjustable C Mount lenses Complete set of Accessories like external lighting systems mounting brackets connection boxes cables and photocells Et...

Page 46: ...1 4 TRIGGER yellow LED indicates the status of the reading phase Figure 21 5 COM yellow LED indicates active communication on the main serial port Figure 21 6 STATUS red LED indicates a NO READ result...

Page 47: ...tion multiple readers ID NET interface allows local connection of multiple readers reading different sides of the same target All readers share a single presence sensor and activate deactivate simulta...

Page 48: ...ch other and they can have different operating modes from each other At the end of each reading phase each reader transmits its own data message to the host Thanks to ID NET data collection among read...

Page 49: ...ime and Gain calibration Learn to self detect and auto configure for reading unknown codes 2 4 1 X PRESS Functions Quick access to the following functions is provided by an easy procedure using the pu...

Page 50: ...OV can be used to position the imager on the code The Focus LED blinks to indicate this state To exit the Focus Locate Mode press the X PRESS push button once The Blue Diamonds and laser pointers turn...

Page 51: ...Learn LED will stop blinking and in this case Matrix 450N emits a long low pitched beep 2 4 2 Diagnostic Indication The STATUS and READY LEDs blink simultaneously to signal the presence of an error Di...

Page 52: ...5 mm C Mount Lens 5MP with anti vibration components 93ACC0034 LNS 1235 35 mm C Mount Lens 5MP with anti vibration components 93ACC0035 LNS 1250 50 mm C Mount Lens 5MP with anti vibration components 9...

Page 53: ...l Master ID NET Profinet IO Gateway 93ACC0038 Various M12 Service Cables and Field Mount Connectors are available for Quick Link Series Connectors Power Supplies PG 120 K01 AC DC Power Supply Kit EU 9...

Page 54: ...ter packs are manually moved across the Matrix 450N scanning zone where two laser pointers mark the center The Sort to Light mode is one of the most common solutions the code s is communicated to the...

Page 55: ...through slot conveyors like cross belts or small drop sorters Easier installation easier maintenance superior performance longer life cycle make Matrix 450N a unique and compelling solution for over t...

Page 56: ...simplifying the integration and eliminating any extra hardware Low aspect ratio codes have no impact on the simplicity of the Matrix 450N reading solution since regular image capture contains any sca...

Page 57: ...ck for the operator to validate a successful reading In order to extend the illuminator life cycle and also to save energy the continuous illumination can be optionally activated on a trigger basis si...

Page 58: ...ontinuous image acquisition the http image mirroring produces a sort of real time video useful feature for local visualization on screen or also for remote monitoring The live streaming uses the stand...

Page 59: ...x 450N reader and all the parts supplied with the equipment are present and intact when opening the packaging the list of parts includes Matrix 450N reader Quick Reference Guide Test Charts 2 Focusing...

Page 60: ...In this configuration Matrix 450N can be installed to operate in different positions using the body mounting bracket accessory shown in Figure 28 The fourteen screw holes M4 on the body of the reader...

Page 61: ...9 202 7 95 5 0 20 130 5 12 200 7 87 179 7 05 90 3 54 9 0 35 65 2 56 30 1 18 62 2 44 50 25 27 5 1 08 34 5 1 36 55 2 17 45 1 77 9 0 35 22 5 0 89 42 5 1 67 20 0 79 20 0 79 60 2 36 compact assembly standa...

Page 62: ...NING MATRIX 450N Using the LT 03x L shaped mounting bracket you can obtain rotation on the various axes of the reader as shown in the diagrams below Figure 25 Mounting LT 03x Bracket Figure 26 Matrix...

Page 63: ...e reader as shown in the diagram below Figure 27 Matrix 450N Positioning with Two LT 03x Brackets In applications where the LT 03x Series Lighting Systems are not used Matrix 450N can be mounted using...

Page 64: ...pplications performance can be improved by modifying the Skew angle The Pitch Tilt and Skew angles are represented in Figure 29 Follow the suggestions below for the best orientation Position the reade...

Page 65: ...many variations can be constructed NOTE For all of the following mounting examples the positioning distances are not given since they depend on the application and characteristics of the reader lens...

Page 66: ...profiles with one bolt in the center position and one bolt in the outer ring 2 Rotate the mirror brackets so that the 15 skew angle slot is aligned with the profile channel see the figure below 3 Moun...

Page 67: ...center the BK 90 040 brackets on the vertical profile 2 Mount the mirror brackets to the BK 90 040 brackets with one bolt in the center position and one bolt in the outer ring 3 Rotate the mirror brac...

Page 68: ...instead of at the reader 1 Mount the mirror brackets to the profiles with one bolt in the center position and one bolt in the outer ring 2 Rotate the mirror brackets so that the 15 skew angle slot is...

Page 69: ...EMK 600 Deflection Mirror 1 Mount and center the BK 90 040 brackets on the vertical profile 2 Mount the mirror brackets to the BK 90 040 brackets with one bolt in the center position and one bolt in t...

Page 70: ...block connectors Use this pinout when the Matrix 450N reader is connected by means of the CBX100 500 CBX100 500 Terminal Block Connectors Input Power Vdc Power Supply Input Voltage GND Power Supply I...

Page 71: ...m device source jumper setting Power must be supplied to the CBX as shown below To power the reader and or I O devices through the CBX power must be supplied to the CBX100 500 spring clamp terminal pi...

Page 72: ...or LT 03x and Matrix 450N make sure that LT 03x is powered up before Matrix 450N in order to be correctly recognized If using customer supplied power keep in mind the following worst case peak current...

Page 73: ...p On Line page of the Reading Phase step Channels in DL CODE Details regarding the connections and use of the interfaces are given in the next paragraphs 4 2 1 RS232 Interface The RS232 interface is g...

Page 74: ...ws CBX100 500 Function TX RS422 Transmit Data RX RS422 Receive Data TX RS422 Transmit Data RX RS422 Receive Data SGND Signal Ground RX422 TX422 SGND RX422 TX422 USER INTERFACE SGND TX RX TX RX READER...

Page 75: ...cable shield as common reference The ID NET max cable length depends on the baudrate used see the Baudrate Table below For Common Power Connections use only 2 wires ID and ID DC Voltage Power cable Vd...

Page 76: ...Time 240 220 200 180 160 140 120 100 80 60 40 20 0 Response Time ms Number of Nodes 500 kbps 250 kbps 125 kbps 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Figure 36 ID NET Response Time CONDITIONS ID NE...

Page 77: ...CBX ELECTRICAL CONNECTIONS 65 4 Figure 37 ID NET Network Connections with isolated power blocks...

Page 78: ...MATRIX 450N REFERENCE MANUAL 66 4 Figure 38 ID NET Network Connections with Common Power Branch Network...

Page 79: ...CBX ELECTRICAL CONNECTIONS 67 4 Figure 39 ID NET Network Connections with Common Power Star Network...

Page 80: ...iary Interface connector inside the CBX is the preferred connector for temporary communication monitoring 5 1 6 9 Figure 40 9 pin female connector If permanent system wiring is required the following...

Page 81: ...ate of these inputs is selected in software An anti disturbance filter by default is implemented in software on both inputs The value can be changed through the software parameter Debounce Filter See...

Page 82: ...ER CAUTION Power from the Vdc GND spring clamps is available directly to the Input Device on the V V spring clamps and does not pass through the Power Switch ON OFF inside the CBX Disconnect the power...

Page 83: ...CBX ELECTRICAL CONNECTIONS 71 4 Figure 43 NPN External Trigger Using CBX Power...

Page 84: ...nce Inputs INPUT 2 CONNECTIONS USING CBX POWER CAUTION Power from the Vdc GND spring clamps is available directly to the Input Device on the V V spring clamps and does not pass through the Power Switc...

Page 85: ...R Figure 46 PNP Input 2 Using External Power Figure 47 NPN Input 2 Using External Power Power to Input Input Device Signal Input Device Reference Input Device Pulled down to External Input Device Refe...

Page 86: ...the following VCE 30 Vdc max ICE 40 mA continuous max 130 mA pulsed max VCE saturation 1 Vdc max 10 mA PD 90 mW Max 50 C ambient temp By default Output 1 is associated with the No Read event which act...

Page 87: ...ter Using External Power Figure 51 NPN Output Open Collector Using External Power Power to Output Output device Signal Output device Reference Output 1 Device Power to Output Output device Signal Outp...

Page 88: ...rface the following communication channels are available TCP Client TCP Server UDP Client FTP Client The following Fieldbus protocols are also available over the on board Gigabit Ethernet interface Et...

Page 89: ...lso configurable as before NOTE The Master Slave Role is only significant for the Internal ID NET Network If your layout doesn t use the ID NET network then the device s Role is not significant and ca...

Page 90: ...re 54 Ethernet Network Layout All devices always support multiple output channels i e for data monitoring Host Matrix 450N CAB GE0x PG 120 Alone CAB LD 002 with power CAB PG 0105 CBX HOST Gigabit Ethe...

Page 91: ...ode operating mode is used the reader can be activated by an External Trigger for example a pulse from a photoelectric sensor when the object enters its reading zone Figure 55 Serial Interface Point t...

Page 92: ...RS232 auxiliary interface independently from the Fieldbus interface selection to monitor data When One Shot or Phase Mode operating mode is used the reader can be activated by an External Trigger pho...

Page 93: ...ations to accept input from different devices on different channels i e middle reader above However readers are not required to have a pass through configuration if they don t need to receive data fro...

Page 94: ...D NET Slave readers are not required to have a pass through configuration if they don t need to receive data from an input channel i e right reader above The ID NET Master always has at least one pass...

Page 95: ...m the Master reader to the Host computer It is not necessary to bring the External Trigger signal to all the readers This allows the more economical QL connections to be used for all Slave readers The...

Page 96: ...with QL100 Host QL100 PS Power Main Interface 1 The ID NET network must be terminated inserting an ID NET terminator into the QL300 Master and into the last QL in the network ID NET Synchronized Slav...

Page 97: ...t interface of each individual reader using the DL CODE configuration program Figure 62 ID NET Synchronized Layout with Master CBX500 Fieldbus Interface to Fieldbus Host QL100 2 1 3 PS Power CBX500 1...

Page 98: ...0 LNS 1250 50 mm 9 2 7 8 12 1 340 The viewing angle has a tolerance of 1 depending on the focus distance FOVx 2 d 44 mm tan x 2 where FOVx horizontal vertical or diagonal FOV x horizontal vertical or...

Page 99: ...Systems are especially effective in high speed code movement applications When defining a HW SW configuration for the Matrix 450N LT 03x assembly for conditions different from those of the reference...

Page 100: ...stem LT 032 LT 032 Software Parameters Exposure Time s 190 250 Max code moving speed 1 8 m s 1 8 m s Gain 13 14 Internal Lighting Very High Power Strobed or Continuous High Power Processing Mode Advan...

Page 101: ...LT 030 LT 031 LT 032 Software Parameters Exposure Time s 60 120 120 Max code moving speed 3 0 m s 1 5 m s 1 5 m s Gain 10 10 17 Internal Lighting Very High Power Strobed or Continuous High Power Proc...

Page 102: ...eters Exposure Time s 150 160 200 120 120 190 Max code moving speed 1 8 m s 1 8 m s 1 5 m s 2 8 m s 2 8 m s 1 8 m s Gain 7 13 16 8 16 15 Internal Lighting Very High Power Strobed or Continuous High Po...

Page 103: ...s 120 120 180 160 160 220 Max code moving speed 2 3 m s 2 3 m s 1 5 m s 3 2 m s 3 2 m s 2 5 m s Gain 7 14 16 6 12 16 Internal Lighting Very High Power Strobed or Continuous High Power Processing Mode...

Page 104: ...032 Software Parameters Exposure Time s 250 250 380 Max code moving speed 1 8 m s 1 8 m s 1 2 m s Gain 8 16 19 Internal Lighting Very High Power Strobed or Continuous High Power Processing Mode Advan...

Page 105: ...030 LT 031 Software Parameters Exposure Time s 150 300 Max code moving speed 1 2 m s 0 6 m s Gain 16 16 Internal Lighting Very High Power Strobed or Continuous High Power Processing Mode Advanced Mini...

Page 106: ...T 031 LT 030 LT 031 Software Parameters Exposure Time s 200 400 150 270 Max code moving speed 1 0 m s 0 5 m s 1 8 m s 1 0 m s Gain 22 22 18 22 Internal Lighting Very High Power Strobed or Continuous H...

Page 107: ...0 LT 031 LT 030 LT 031 Software Parameters Exposure Time s 230 400 150 270 Max code moving speed 2 0 m s 1 0 m s 3 0 m s 1 7 m s Gain 20 23 18 22 Internal Lighting Very High Power Strobed or Continuou...

Page 108: ...Skew Angle 15 Lighting System LT 030 LT 031 Software Parameters Exposure Time s 70 130 Max code moving speed 1 8 m s 1 0 m s Gain 16 18 Internal Lighting Very High Power Strobed or Continuous High Pow...

Page 109: ...codes or postal code reading applications heavily depends on the direction of symbol movement When the direction of movement is parallel to the elements of the code the maximum speed is greater Assum...

Page 110: ...me value obtainable for the specific application It can be evaluated in static reading conditions and depends on the Matrix reader hardware selected for the application LT 03x lighting system model op...

Page 111: ...One 19 or larger monitor optimized for 1280x1024 resolution 7 2 READER CONFIGURATION For an example of Matrix device configuration see the example in chapter 1 Steps 7 8 NOTE Especially for lengthy co...

Page 112: ...mage Setup step the following window appears Figure 64 Image Auto Setup Select the Static or Dynamic Self Tuning option Start Autolearn and Apply to the Image Setup The Image Setup window works intera...

Page 113: ...ers in their order of appearance 1 increase the Exposure Time 2 increase the Gain NOTE In general a longer exposure time corresponds to a lighter image but is susceptible to blurring due to code movem...

Page 114: ...MANUAL 102 7 Over exposure To correct this result it is recommended to change the following parameters in their order of appearance 1 decrease the Gain 2 decrease the Exposure Time Figure 67 Example O...

Page 115: ...he Field of View To correct this result and have the code completely visible in FOV it is possible to follow one or both the procedures listed below reposition the reader use the Delay on Trigger and...

Page 116: ...vely by an activation event For example an application may have several stable but different lighting conditions which require different lighting options One Image Acquisition Setting could enable and...

Page 117: ...means that for N acquisitions we will surely have captured the correct lighting condition but we will also have captured some acquisitions with the wrong lighting condition A consequence then is that...

Page 118: ...we can pre select the correct Image Setting from an external source When the Image Settings Selection is External Acquisition Sequences are created and by default each Image Setting has its own Acqui...

Page 119: ...ence box Select the empty Sequence box and delete it with the delete key Each Acquisition Sequence can be activated exclusively by a single event either through a string from an available communicatio...

Page 120: ...ping is performed from the Image Setup tab by clicking on the Add Cropping Region icon as shown below In Matrix 450N the frame rate is dependent on the number of rows and columns in the defined window...

Page 121: ...fault is equal to the FoV By dragging the edges with the mouse resizing you can crop the image to a specific location where codes are present The numbers in the blue boxes refer to pixel references x...

Page 122: ...UAL 110 7 The cropped area can be moved by dragging the center You can also set the cropped image size and position through the Cropping Region Area group of parameters size Width and Height position...

Page 123: ...and or small size codes This algorithm is much more aggressive but in general it may have longer decoding times than the lower complexity algorithms To minimize decoding time it is better to select t...

Page 124: ...single code or group of codes in one or more Image Settings See the DL CODE User s Manual for examples of Image Filter application The Erode Filter enlarges the image dark zones to increase readabili...

Page 125: ...13 7 The Open filter eliminates white areas defects in the dark zones of the image Before No Read After Readable Open The Contrast Stretching filter maximizes image contrast Before No Read After Reada...

Page 126: ...distribution uniform Before No Read After Readable Histogram Equalization The Smoothing filter deletes small insignificant details in the center of the image Before No Read After Readable Smoothing Th...

Page 127: ...able Deblurring The Black Enhancement filter produces a nonlinear increase in the black level for light images Before No Read After Readable Black Enhancement The White Enhancement filter produces a n...

Page 128: ...device configurations The pass through configuration allows individually working devices Alone to collect data from other devices also working Alone and pass this data to a third device through a dif...

Page 129: ...settings Layout Type Alone Internal Network Role Slave In order to automatically recognize the ID NET Slaves all devices must be physically installed and electrically connected including ID NET networ...

Page 130: ...n as ID NET Master current default setting is Slave Click on Setup Internal Network Configuration from the Task area You will be advised that the device role will be changed to Master Click OK The Net...

Page 131: ...recognized If not verify all device connections and power and then repeat the operation by clicking on the Start Net Autoset button Depending on the application select one of the Default Internal Netw...

Page 132: ...EFERENCE MANUAL 120 7 This selection will open a pre configured job for the Master reader according to the selection Follow the specific application instructions in the following paragraphs Synchroniz...

Page 133: ...on to Clone Master configuration on Slaves Figure 70 Saving Multidata Configuration to Master The jobs must not be cloned because the Master and Slaves have different input output communication channe...

Page 134: ...MATRIX 450N REFERENCE MANUAL 122 7 Open the Slave specific application job the first time it has the Master Specific name...

Page 135: ...URATION 123 7 When the configuration opens pause run mode and set all the application specific configuration parameters including Image Setup Verify the focus and decoding with the capture image and C...

Page 136: ...The following screenshots show the pass through configuration settings for the three devices in the example in par 5 5 4 An application job with the same name as the Master s but with Slave specific c...

Page 137: ...SOFTWARE CONFIGURATION 125 7 ID NET Master ID NET Slave 1 ID NET Slave 2...

Page 138: ...onfiguration of all the application parameters including Image Setup and save them to the Master with an application relative name and with the option to Clone Master configuration on Slaves Figure 72...

Page 139: ...SOFTWARE CONFIGURATION 127 7 Open the cloned application job...

Page 140: ...meters Image Auto Setup feature in the Image Setup step Acquisition Trigger Delays necessary to avoid lighting interference between adjacent or oppositely positioned readers Reading Phase step Images...

Page 141: ...the entire network is configured See par 5 6 for an example Synchronized ID NET configuration 5 An application job with the same name as the Master s has been cloned to the Slaves Each Slave can have...

Page 142: ...he DL CODE Console or a configured channel terminal If necessary as a troubleshooting tip you can temporarily apply the Reading Mask field in place of each Code Content field to verify if all devices...

Page 143: ...he Slaves are shown in order from right to left 1 to 31 Example Master Slave 1 00000000000000000000000000000011 The figure above shows the Master reading Code 128 and Slave 1 reading Code 39 3 After v...

Page 144: ...on tab at the bottom of the screen By selecting the various configuration steps above you can visualize the slave configuration NOTE You can modify some Slave Synchronized parameters from this view bu...

Page 145: ...all Slaves present in the network CAUTION For Master Slave networks any other configurations jobs stored in the device memory will not be backed up Therefore upon a restore all jobs other than the sta...

Page 146: ...Master only select the Backup current Internal Network configurations selection You will be reminded that configuration in temporary memory will not be saved so you should save the configuration to t...

Page 147: ...cating successful completion 7 5 3 Replacement CAUTION The replacement device must be the exact same model as the device it is replacing The Restore function also provides easy and secure Single Devic...

Page 148: ...le configurations jobs are saved on a single device these parameters can be different from one configuration to the next Environment parameters regard the device Identity and Position in a Network Eth...

Page 149: ...ation is set as the startup configuration 7 6 2 Restore Default Environment Restore Default Environment returns all Environment parameters to their factory default settings The default IP address will...

Page 150: ...prompted to confirm All Environment parameters will be restored to Factory default values and any existing configurations stored on the device will be erased The device will be reset and therefore sta...

Page 151: ...ng performance can be viewed by enabling the Statistics panel from the DL CODE Monitor item selected from the File menu or Monitor icon Figure 75 Reading Statistics The enabled Statistical Counters ca...

Page 152: ...herefore the BM150 display module if present will also be enabled Unchecked Disabled the BM100 backup memory module will not be detected on power up reset therefore the BM150 display module if present...

Page 153: ...select an item or enter a submenu press and release the Enter key After executing an HMI function the display shows a result message and then automatically exits from the menu structure To exit a menu...

Page 154: ...Type MUL Multidata SYN Synchronized ALN Alone N Device Network Setting M00 ID NET Network Master Sxx ID NET Network Slave address Null string Alone no network D device serial number A Ethernet IP Addr...

Page 155: ...ress Duplication 171 Protocol Index Failure 185 Backup Memory Communication Failure 187 Wrong Rotary Switch Selection 189 Fieldbus Communication Failure 191 Fieldbus Type Mismatch 193 Fieldbus Configu...

Page 156: ...for Stand Alone or Master plus Slave readers 1 15 0 No Read 1 Good Read M Multiple Read T Reading Mask for Slave readers 16 31 0 No Read 1 Good Read M Multiple Read Reading Mask Device State Master O...

Page 157: ...the Startup Configuration for the Master and all Slaves present in the network CAUTION For Master Slave networks any other configurations jobs stored in the device memory will not be backed up Therefo...

Page 158: ...gure A 3 periodically for continued correct operation of the reader Dust dirt etc on the lens cover may alter the reading performance Repeat the operation frequently in particularly dirty environments...

Page 159: ...tion host mshta exe in Windows System32 Power ON the POWER LED is not lit Is power connected If using a power adapter like PG6000 is it connected to wall outlet If using rail power does rail have powe...

Page 160: ...the Reading Phase step and the Data Formatting parameters on the data Formatting step Image not clear verify the Focus procedure Image focused but not decoded verify the Calibrate Image Density proced...

Page 161: ...nu item is grey Are you using the Installer Expert User level If not change it in the Options Change User menu How do I obtain my reader Serial Number The reader Serial Number consists of 9 characters...

Page 162: ...ators to EN 62471 Laser Safety Class pointers Class 2 Laser Light to IEC60825 1 ENVIRONMENTAL FEATURES Operating Temperature6 0 to 50 C 32 to 122 F Storage Temperature 20 to 70 C 4 to 158 F Max Humidi...

Page 163: ...dard and Direct Marking MicroQR Code MAXICODE Aztec Code Australia Post Royal Mail 4 State Customer Kix Code Japan Post PLANET POSTNET POSTNET BB Intelligent Mail Swedish Post Operating Mode CONTINUOU...

Page 164: ...6 19 pin Male Power COM and I O Connector Power COM and I O Connector Pinout Pin Name Function A Vdc Power supply input voltage L GND Power supply input voltage K CHASSIS Cable shield internally conne...

Page 165: ...system through the CAB LD 002 cable Matrix 450N cannot source power through this connector Figure 78 M12 8 pin Male Lighting System Control Connector Matrix 450N M12 8 pin Lighting System Connector P...

Page 166: ...for Matrix 450N LT 03x assemblies Accessory Power Supplies Power Supply Number of Matrix 450N LT 03xs Supported PG 120 1 PWR 120 1 PWR 480B 4 NOTE If using separate power sources for LT 03x and Matrix...

Page 167: ...ve pin 2 DD Channel D bi directional data positive pin 3 DD Channel D bi directional data negative pin 4 DA Channel A bi directional data negative pin 5 DC Channel C bi directional data positive pin 6...

Page 168: ...ion A Vdc Power Supply input voltage B I1A External Trigger A polarity insensitive C I1B External Trigger B polarity insensitive D I2A Input 2 A polarity insensitive E I2B Input 2 B polarity insensiti...

Page 169: ...Line page for the Output Setup step in DL CODE Figure 83 Isolated Current Sinking Output Connection Figure 84 Isolated Current Sourcing Output Connection Figure 85 Non Isolated Current Sinking Output...

Page 170: ...TX 2 TX 5 GND 7 GND How To Build A Simple Interface Test Cable The following wiring diagram shows a simple test cable including power external push button trigger and PC RS232 COM port connections Fig...

Page 171: ...ction of ROM based code with a standard API used to interface with standard PC hardware Bit Binary digit One bit is the basic unit of binary information Generally eight consecutive bits compose one by...

Page 172: ...ost A computer that serves other terminals in a network providing services such as network control database access special programs supervisory programs or programming languages Image Processing Any f...

Page 173: ...center distance of adjacent elements is uniform Matrix symbols may include recognition patterns which do not follow the same rules as the other elements within the symbol Multi row or Stacked Symbolog...

Page 174: ...onse Time 64 ID NET Synchronized Network 83 Image Cropping 108 Inputs 69 156 Internal Network Configurations 117 L Layouts 77 M Main Serial Interface 61 Maintenance 146 Manual Calibration 101 Mechanic...

Page 175: ......

Reviews: