background image

Datalogic S.r.l.

Via San Vitalino 13

40012 Calderara di Reno (BO) 

Italy

Tel. +39 051 3147011

Fax +39 051 3147205

©2016-2017 Datalogic S.p.A. and/or its affiliates 

 All rights reserved. 

 Without limiting the rights under copyright, no part of this documentation may be reproduced,

stored in or introduced into a retrieval system, or transmitted in any form or by any means, or for any purpose, without

the express written permission of Datalogic S.p.A. and/or its affiliates. Owners of Datalogic products are hereby granted

a  non-exclusive,  revocable  license  to  reproduce  and  transmit  this  documentation  for  the  purchaser's  own  internal

business purposes. Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in

this documentation and shall ensure that all notices appear on any reproductions of the documentation. Should future

revisions of this manual be published, you can acquire printed versions by contacting your Datalogic representative.

Electronic  versions  may  either  be  downloadable  from  the  Datalogic  website 

(www.datalogic.com

)  or  provided  on

appropriate  media.  If  you  visit  our  website  and  would  like  to  make  comments  or  suggestions  about  this  or  other

Datalogic publications, please let us know via the "Contact Datalogic" page.

Safety & Regulatory Addendum

  (Rev. A)   

   October 2017

General Safety Rules

Power Supply

The device is intended to be supplied by a self-contained rechargeable Lithium Ion battery pack

(UL  listed  LPS/SELV  power  source)  and/or  by  UL  Listed/CSA  Certified  Power  Unit  LPS/SELV

power source which supplies power directly to the unit via the micro USB connector of the cable.

The device  could be  also used with Certified  Accessories (Dock/Cradle) which supply Wireless

power. The Dock/Cradle accessories are intended to be supplied by a UL Listed/CSA Certified

Power  Unit  LPS/SELV  rating  12V,  min  5A  power  source  which  supplies  power  via  the  power

connector of the cable. 

Any changes or modifications to equipment, not expressly approved by Datalogic could void the

user's authority to operate the equipment.

Battery Information

By  default,  the  main  battery  pack  is  disconnected  at  the  factory  to  avoid  damage  due  to

excessive draining.

Rechargeable battery  pack is less than half of  full charge when  delivered. Charge the battery

pack as indicated in the Quick Start Guide or in the User Manual, before using the MEMOR 10

terminal.

The battery pack autonomy varies according to many factors, such as the frequency of barcode

scanning, RF usage, battery life, storage, environmental conditions, etc.

Close  to  the  limits  of  the  working  temperature,  some  battery  performance  degradation  may

occur.

The MEMOR 10 should be charged at an ambient temperature between 0 - 35º C (32 to 122ºF) to 

achieve the maximum charging rate. 

Never charge the device battery in a closed space where excessive heat can build up. 

As a safety precaution, the battery may stop charging to avoid overheating.

The MEMOR 10 gets warm during charging; this is normal and does not mean a malfunction. 

Even if the storage temperature range is wider, it is recommended to store the terminal and the

batteries at environmental temperature, in order to achieve the longest battery life.

NOTE

Read  carefully  the  MEMOR 10  user  manual  (available  at 

www.datalogic.com

)  before

performing any type of connection to the MEMOR 10.

The  user  is  responsible  for  any  damage  caused  by  incorrect  use  of  the  equipment  or  by

inobservance of the indication supplied in the user manual.

CAUTION

Before using the devices and the battery packs, read this Addendum carefully.

Use only the components and accessories supplied by the manufacturer for the

specific MEMOR 10 being used.

Do not attempt to disassemble the MEMOR 10 device, as it does not contain

parts that can be repaired by the user. Any tampering will invalidate the

warranty.

When replacing the battery pack or at the end of the operative life of the

MEMOR 10 device, disposal must be performed in compliance with the laws

in force in your jurisdiction.

Do not submerge the MEMOR 10 in liquid products.

For  further  information  or  support,  refer  to  the  Datalogic  web  site:

www.datalogic.com

.

CAUTION

Do not apply any sticker to the MEMOR 10.

CAUTION

Do not incinerate, disassemble, short terminals, or expose to high temperature. Risk of fire and

explosion. Use specified charger only. Risk of explosion if the battery is replaced by an incorrect

type. Dispose of batteries as required by local authorities.

CAUTION

Avoid storing batteries for long periods in a state of full charge or very low charge.

We recommend charging the battery pack every two to three months to keep its charge at a

moderate level to maximize battery life.

Annual replacement of rechargeable battery pack avoids possible risks or abnormalities and

ensures maximum performance.

WARNING

Use only Datalogic approved batteries and accessories for battery charging.

Risk of explosion if battery is replaced by an incorrect type.

Dispose of used batteries according to the instructions.

Il y a risque d’explosion si la batterie est remplacée par une batterie de type incorrect.

Mettre au rebut les batteris usagées confor mément aux instructions.

CAUTION

Do not put any foreign object such as, but not limited to, coins, paper clips, stickers inside the

slot of any of the docks (see the examples below).

Battery Safety Guidelines

Wireless and Radio Frequencies Warnings

WARNING

Installing,  charging  and/or  any  other  action  should  be  done  by  authorized  personnel  and

following this manual.

The  battery  pack  may  get  hot,  explode,  ignite,  and/or  cause  serious  injury  if  exposed  to

abusive conditions.

If the battery pack is replaced with an improper type, there is risk of explosion.

Do not place the battery pack in or near a fire or other heat source; do not place the battery

pack in direct sunlight, or use or store the battery pack inside unventilated areas in hot

weather; do not place the battery pack in microwave ovens, in clothes dryers, in high pressure

containers, on induction cook surfaces or similar devices. Doing so may cause the battery pack

to generate heat, explode or ignite. Using the battery pack in this manner may also result in a

loss of performance and a shortened life expectancy.

To power the cradle, use only a Datalogic approved power supply. The use of an alternative

power supply will void the product warranty, may cause product damage and may cause heat,

an explosion, or fire.

The area in which the units are charged should be clear of debris and combustible materials or

chemicals.

Do not use the battery pack of this terminal to power devices other than this device.

Immediately discontinue use of the battery pack if, while using, charging or storing the battery

pack, the battery pack emits an unusual smell, feels hot, changes colour or shape, or appears

abnormal in any other way.

Do not short-circuit the battery pack contacts connecting the positive terminal and negative

terminal. This might happen, for example, when you carry a spare battery pack in your pocket

or purse; accidental short–circuiting can occur when a metallic object such as a coin, clip, or

pen causes direct connection of the contacts of the battery pack (these look like metal strips

on the battery pack). Short–circuiting the terminals may damage the battery pack or the

connecting object.

Do not apply voltages to the battery pack contacts.

Do not pierce the battery pack with nails, strike it with a hammer, step on it or otherwise

subject it to strong impacts, pressures, or shocks.

Do not disassemble or modify (i.e. bend, crush or deform) the battery pack. The battery pack

contains safety and protection devices, which, if damaged, may cause the battery pack to

generate heat, explode or ignite.

In case of leakage of liquid from the battery, avoid contact with liquid the skin or eyes. If the

contact occurs, immediately wash the affected area with water and consult a doctor.

Do not solder directly onto the battery pack.

Do not expose the battery pack to liquids.

Avoid any knocks or excessive vibrations. If the device or the battery is dropped, especially on

a hard surface, you should take it to the nearest Authorised Repair Centre for inspection

before continuing to use it.

If your device stops working for any reason, do not use its battery on other electronic devices

without a prior check and approval by an Authorised Repair Centre.

Do not remove or damage the battery pack’s label.

Do not use the battery pack if it is damaged in any part.

Battery pack usage by children should be supervised.

Collect and recycle waste batteries separately from the device in compliance with European

Directive 2006/66/EC, 2011/65, 2002/96/EC and subsequent modifications, with US and

China regulatory laws and regulations about the environment.

WARNING

Use  only  the  supplied  or  an  approved  replacement  antenna.  Unauthorized  antennas,

modifications or attachments could damage the product and may violate laws and

regulations.

Most modern electronic equipment is shielded from RF signals. However, certain electronic

equipment may not be shielded against the RF signals generated by MEMOR 10.

Datalogic recommends persons with pacemakers or other medical devices to follow the same

recommendations provided by Health Industry Manufacturers Associations for mobile

phones.

Persons with pacemakers:

Should  ALWAYS  keep  this  device  more  than  twenty  five  (25)  cm  from  their

pacemaker and/or any other medical device;

Should not carry this device in a breast pocket;

Should keep the device at the opposite side of the pacemaker and/or any other

medical device;

Should  turn  this  device  OFF  or  move  it  immediately  AWAY  if  there  is  any

reason to suspect that interference is taking place.

Should ALWAYS read pacemaker or any other medical device guides or should

consult the manufacturer of the medical device to determine if it is adequately

shielded from external RF energy.

In case of doubt concerning the use of wireless devices with an implanted medical device,

contact your doctor.

Turn this device OFF in health care facilities when any regulations posted in these areas

instruct you to do so. Hospitals or health care facilities may use equipment that could be

sensitive to external RF energy.

RF signals may affect improperly installed or inadequately shielded electronic systems in

motor vehicles. Check with the manufacturer or its representative regarding your vehicle. You

should also consult the manufacturer of any equipment that has been added to your vehicle.

An air bag inflates with great force. DO NOT place objects, including either installed or portable

wireless equipment, in the area over the air bag or in the air bag deployment area. If a

vehicle’s wireless equipment is improperly installed and the air bag inflates, serious injury

could result.

Turn off the device  when in any  area with a  potentially explosive atmosphere. Observe

restrictions and follow closely any laws, regulations, warnings and best practices on the use

of radio equipment near fuel storage areas or fuel distribution areas, chemical plants or where

any operation involves use of explosive materials.

Do not store or carry flammable liquids, explosive gases or materials with the device or its

parts or accessories.

Areas with a potentially explosive atmosphere are often, but not always, clearly marked or

shown.

Sparks in such areas could cause an explosion or fire, resulting in injury or even death.

This  document  is  an  addendum  to  the  Quick 

Start Guide (QSG) for this product. See the QSG 

for additional product information.

www.datalogic.com

     

852001650 

  (Rev. A)   

   July 2019

Rugged Mobile Computer 

with 1D/2D Imager

FCC compliance

NOTICE:

This device complies with Part 15 of the FCC Rules.

Operation is subject to the following two conditions:

(1) This device may not cause harmful interference.

(2) This device must accept any interference received, including

interference that may cause undesired operation.

FCC ID: U4GDL35US

Disclaimer

Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, 

Datalogic reserves the right to change any specification at any time without prior notice.

Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and 

the E.U. Memor is a trademark of Datalogic S.p.A. and/or its affiliates 

All other trademarks and brands are property of their respective owners. Google, Google Play and other marks are 

trademarks of Google LLC.

Patents

See 

www.patents.datalogic.com

 for patent list.

This product is covered by one or more of the following patents:

Design patents: EP004675072, EP004803013, EP005513751

Utility patents: EP0999514B1, EP0996284B1, EP1128315B1, , EP1396811B1, EP1413971B1, , EP1828957B1, EP2517148B1

US6808114, US6997385, US7053954, US7234641, US7387246, US8888003, US8915443, US9798948, ZL200980163411.X

NOTE: 

Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to 

operate the equipment.

NOTE:

 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC- 

Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This 

equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, 

may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particul-

ar installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning 

the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

---Reorient or relocate the receiving antenna.

---Increase the separation between the equipment and receiver.

---Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

---Consult the dealer or an experienced radio/TV technician for help.

Body-worn Operation

This device was tested for typical body-worn operations. To comply With RF exposure requirements, a minimum separation distance 

of 1.0cm must be maintained between the user’s body and the handset, including the antenna. Third-party belt-clips, holsters, and 

similar including the antenna. Third-party belt-clips, holsters, and similar accessories used by this device should not contain any 

metallic com-ponents. Body-worn accessories that do not meet these requirements may not comply with RF exposure requirements 

and should be avoided.

Specific Absorption Rate (SAR) information:

This wireless phone meets the government's requirements for exposure to radio waves. The guidelines are based on standards that 

were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards 

include a substantial safety margin designed to assure the safety of all persons regardless of age or health.

FCC RF Exposure Information and Statement: 

The SAR limit of USA (FCC) is 1.6 W/kg averaged over one gram of tissue. Device types: U4GDL35US has also been tested against this 

SAR limit. The highest SAR value reported under this standard during product certification for use at the ear is 0.801W/kg and when 

properly worn on the body is 1.

 and as hotspot is 

 . This device was tested for typical body-worn operations with 

the back of the handset kept 1cm from the body. To maintain compliance with FCC RF exposure requirements, use accessories that 

maintain a 1cm separation distance between the user's body and the back of the handset. The use of belt clips, holst-ers and similar 

accessories should not contain metallic components in its assembly. The use of accessories that do not satisfy these requirements 

may not comply with FCC RF exposure requirements, and should be avoided.

The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-

channel mobile satellite systems; 

ISED Compliance

NOTICE:

This device complies with Industry Canada licence-exempt RSS standard(s).

Operation is subject to the following two conditions:

(1)this device may not cause harmful interference, and 

(2)this device must accept any interference received, including interference that may cause undesired operation.

 

Cleaning The Device

LED Class

CAUTION

the device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-

channel mobile satellite systems;

high-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350MHz and 5650-5850 MHz and tha t

these radars could cause interference and/or damage to LE-LAN devices.

801

 1.

 ssttaatteem

meenntt

 

e

 eexxppoossuurre

 

n

 rraaddiiaattiioon

 

D

ISSEED

I

This device is compliant with SAR for general population/uncontrolled exposure limits in RSS-102 and has been tested in accordance 

with the measurement methods and procedures specified in IEEE 1528 and IEC 62209. This equipment should be installed and 

operated with a minimum distance of 0.39 in(10mm) between the radiator and you body. This device and its antennas must not be 

co-located or operated in conjunction with and other antenna or transmitter.

Cet appareil est conforme aux limites d'exposition DAS incontrôlée pour la population générale de la norme CNR-102 

Innovation. Scinces et Développement économique Canada et a été testé en conformité avec les méthodes de mesure de procédures 

spécifiées dans IEEE 1528 et IEC 62209. Cet appareil doit être installé et utilisé avec une distance minimale de 

10mm entre I'émetteur et votre corps. Cet appareil et sa ou ses antennes ne doivent pas être co-localisés ou fonctionner en 

conjonction avec tout autre antenne ou transmetteur.

©2016-2017  Datalogic  S.p.A.  and/or  its  affiliates.  All 

rights  reserved.  Datalogic  and  the  Datalogic  logo  are 

registered  trademarks  of  Datalogic  S.p.A.  in  many 

countries, including the U.S. and the E.U.

Periodically clean the MEMOR 10 using a soft cloth slightly dampened with only water or 

Isopropyl Alcohol (70%). Do not use any other cleaning agents (e.g. different alcohol, abrasive 

or corrosive products, solvents) or abrasive pads to clean the device. 

Do not spray or pour liquids directly onto the device. 

The device is IP65 waterproof.

 

   

LED illuminator integrated in the imager engine is classified as “EXEMPT RISK GROUP” 

according to IEC62471.

Memor™ 10

Reviews: