Smartek Cameras
MX-E Series Hardware Guide
Datalogic S.r.l.
66
Smartek Cameras
S m a r t e k C a m e r a C o n n e c t i o n
Camera power, trigger signal, and strobe trigger can be connected to the camera using one of two
methods: a terminal block with a cable or an unterminated cable. Use a terminal block (248-0136)
with the optional Hirose 12-pin to HD-15 camera cable (606-0673-xx). Without a terminal block,
use the optional Hirose 12-pin to unterminated cable (part number 606-0671-xx).
NOTE: Do NOT use terminal block 248-0141 to connect this camera. It will NOT provide the cor-
rect signal levels.
WARNING: THE POWER AND GROUND CONNECTIONS FOR THIS CAMERA ARE
DIFFERENT FROM OUR CAMERAS AND OTHER THIRD-PARTY CAMERAS. USE CAUTION WHEN CON-
NECTING POWER TO THESE CAMERAS.
Model
(GigE)
Resolution
Color
Image
Horizontal
Image Vertical
FPS
(Approx)
Minimum Software
Version Required
GC651M
.3
No
659
494
120
11.2.0
GC652M
.3
No
659
494
90
11.2.0
GC653M
.3
No
659
494
90
11.2.0
GC781M
.5
No
782
682
64
11.2.0
GC1021M
1
No
1024
1024
60
11.2.1
GC1031M
.8
No
1034
770
30
11.2.0
GC1291M
1.2
No
1296
966
30
11.2.0
GC1391M
1.4
No
1392
1040
20
11.2.0
GC1392M
1.4
No
1392
1040
30
11.2.0
GC1601M
1.9
No
1600
1200
30
11.2.1
GC1621M
2
No
1628
1236
25
11.2.0
GC1921M
2
No
1920
1080
32
11.2.1
GC2441M
5
No
2448
2050
15
11.2.0
Terminal
Color
Signal Name
Notes
1
Wht/Blu
Camera Power Ground
2
Wht/Org
Camera Power VCC
+12 VDC @ 300 mA Max (3.6 W)
Minimum: +10 VDC
Maximum: +24 VDC
3
Wht/Brn
Strobe Trigger -
270 Ohm 2W resistor between Wht/Brn wire and Strobe
Power Ground
4
Brn/Wht
Strobe T
+5 to +24 VDC
Maximum: +24 VDC
5
Wht/Grn
DO NOT USE
Summary of Contents for MX-E Series
Page 1: ...MX E Series Hardware Guide for Processor and Cameras Revision Date July 19 2018...
Page 4: ......
Page 18: ...Before You Call MX E Series Hardware Guide Datalogic S r l 12...
Page 28: ...Battery MX E Series Hardware Guide Datalogic S r l 22...
Page 56: ...JAI Cameras MX E Series Hardware Guide Datalogic S r l 50 661 0402TerminalBlockDimensions...
Page 58: ...JAI Cameras MX E Series Hardware Guide Datalogic S r l 52 JAITerminalConnections sinking...
Page 64: ...Basler Cameras MX E Series Hardware Guide Datalogic S r l 58 TerminalConnections...