Battery
2-9
Datalogic S.r.l.
Battery
WARNING
: Risk of explosion if battery is handled improperly or replaced by an incorrect type. Do not recharge,
disassemble, or dispose of in fire. Lithium batteries are considered hazardous waste. Dispose of used batteries
according to battery maker’s instructions or in accordance with applicable local regulations.
The lithium battery (CR2477N, 3 V, 950 mAh) powers the internal real-time clock (RTC). It is located behind the proces-
sor’s front cover. The battery has a limited service life and should be replaced at least every four years.
WARNING
: Power must be disconnected before replacing the battery.
To replace the battery
1. Disconnect the power supply to the processor.
2. Touch the housing or ground connection in order to discharge any electrostatic charge from your body.
3. Press down on the slot cover’s top clip to open the battery slot.
4. Do not hold the battery by its edges. Using the removal strip, carefully pull the battery out of its slot.
5. Insulated tweezers may be used to insert the new battery in the slot. Be sure the removal strip is in place to make
the next battery replacement easier.
6. Reconnect the power supply to the processor.
7. Reset the date and time in the BIOS.
Battery Slot cover open
Processor Front View
Battery
Summary of Contents for MX-U81
Page 1: ...MX U81 Hardware Guide for Processor and Cameras Revision Date October 26 2017 ...
Page 4: ......
Page 26: ...Battery MX U81 Hardware Guide Datalogic S r l 2 10 ...
Page 33: ...MX U81 Hardware Guide U1xx Camera Connection 3 7 Datalogic S r l U1xx Terminal Connections ...
Page 52: ...JAI Camera MX U81 Hardware Guide Datalogic S r l 3 26 ...
Page 64: ...U1xx MX U81 Hardware Guide Datalogic S r l 5 4 ...