background image

USB-OEM Interface

86

PowerScan

TM

 PD7100 Corded

USB-OEM Device Usage

The USB-OEM protocol allows for the reader to be identified as one of two different 
types of barcode scanners. Depending on what other scanners you may already have con-
nected to a USB-OEM POS, you may need to change this setting to enable all devices to 
communicate.
Options are:

• Table Top Scanner

• Handheld Scanner

NOTE

It may be necessary to switch device usage when connecting two
readers/scanners of the same type to a POS system.

ENTER/EXIT PROGRAMMING MODE

USB-OEM Device Usage = Table Top Scanner

USB-OEM Device Usage = Handheld Scanner

DEFAULT

Summary of Contents for PD7110-BB

Page 1: ...pport POSMicro com Monday Friday 6 AM to 5 PM Pacific Time Bulk Discounts FREE SHIPPING SE Habla Espa ol Free ground shipping to the continental USA on orders over 100 For Help Call 1 800 241 6264 Dat...

Page 2: ...PowerScanTM PD7100 Industrial Corded Handheld Linear Imager Bar Code Reader Product Reference Guide...

Page 3: ...06 5015831 5019697 5019698 5086879 5115120 5144118 5146463 5179270 5198649 5200597 5202784 5208449 5210397 5212371 5212372 5214270 5229590 5231293 5232185 5233169 5235168 5237161 5237162 5239165 52471...

Page 4: ...mission 9 Resetting the Product Configuration to Defaults 9 Chapter 3 Interfaces 11 Interface Selection 11 Configuring the Interface 11 Global Interface Features 15 Host Commands Obey Ignore 15 USB Su...

Page 5: ...haracter 66 Enable Character 68 Chapter 7 Keyboard Interface 71 Introduction 71 Standard Factory Settings 71 Scancode Tables 71 Country Mode 72 Caps Lock State 75 Numlock 75 Send Control Characters 76...

Page 6: ...ck Character Transmission 126 Expand UPC A to EAN 13 127 UPC A Number System Character Transmission 127 In Store Minimum Reads 128 UPC E 129 UPC E Enable Disable 129 UPC E Check Character Transmission...

Page 7: ...n 170 Code 39 Start Stop Character Transmission 170 Code 39 Full ASCII 171 Code 39 Quiet Zones 172 Code 39 Minimum Reads 173 Code 39 Decoding Level 174 Code 39 Length Control 176 Code 39 Set Length 1...

Page 8: ...aracter Transmission 229 Codabar Start Stop Character Transmission 229 Codabar Start Stop Character Set 230 Codabar Start Stop Character Match 231 Codabar Quiet Zones 232 Codabar Minimum Reads 233 Cod...

Page 9: ...128 Force Concatenation 286 ISBT 128 Advanced Concatenation Options 286 MSI 287 MSI Enable Disable 287 MSI Check Character Calculation 288 MSI Check Character Transmission 289 MSI Length Control 289...

Page 10: ...Follett 2 of 5 333 Follett 2 of 5 Enable Disable 333 Appendix A Technical Specifications 335 Standard Cable Pinouts 337 Appendix B Standard Defaults 339 Default Exceptions 350 Appendix C LED and Beepe...

Page 11: ...8 PowerScanTM PD7100 Corded...

Page 12: ...using a serial or USB cable and can also create configuration barcodes to print Manual Overview Chapter 1 Introduction provides a product overview unpacking instructions and cable connection informati...

Page 13: ...e scanned for certain parameter set tings Appendix F Scancode Tables lists control character emulation information for Wedge and USB Keyboard interfaces Manual Conventions The following conventions ar...

Page 14: ...are updates demos and instructions for returning products for repair Reseller Technical Support An excellent source for technical assistance and information is an authorized Datalogic reseller A resel...

Page 15: ...Introduction 4 PowerScanTM PD7100 Corded NOTES...

Page 16: ...design of the reader will help to promote comfortable han dling during extended periods of use See Interface Selection on page 11 for a listing and descriptions of available interface sets by model ty...

Page 17: ...p the retainer over the cable connector as shown in the illustra tion then fully seat the cable assembly into the reader aligning both the connector and the retainer boss with their respective opening...

Page 18: ...n Connection Connect the reader to the Wand Emulation port on the terminal PC using the correct cable Reference Figure 2 Figure 2 Other Interface Connections Programming The reader is factory configur...

Page 19: ...code in that section to select your system s correct interface type Configure Interface Settings If after scanning the interface barcode from the Interfaces section your installation requires you to s...

Page 20: ...to restore the Factory Configuration you have two options You can scan the Restore USA Factory Configuration bar code or the Restore EU Factory Configuration bar code below Both labels restore the ima...

Page 21: ...Getting Started 10 PowerScanTM PD7100 Corded NOTES...

Page 22: ...ll be connected to Next proceed to the corre sponding chapter in this manual also listed in Table 1 to configure any desired settings and features associated with that interface NOTE Unlike some other...

Page 23: ...UPOS JavaPOS Select RS 232 OPOS Select USB COM STDa USB Com to simulate RS 232 standard interface IBM FEATURES Select IBM P5B IBM 46xx Port 5B reader interface Set IBM Interface Features starting on p...

Page 24: ...n page 71 Select KBD AT NK Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Alternate Key Select KBD AT ALT Select K...

Page 25: ...eyboard Wedge for IBM Terminals 31xx 32xx 34xx 37xx make break keyboard Keyboard Wedge for DIGITAL Terminals VT2xx VT3xx VT4xx Select KBD DIG VT Select USB Keyboard USB Keyboard with standard key enco...

Page 26: ...n page 45 Keyboard Interface on page 71 USB OEM Interface on page 85 IBM 46XX Interface on page 89 Host Commands Obey Ignore This option specifies whether the reader will obey or ignore host commands...

Page 27: ...6 PowerScanTM PD7100 Corded USB Suspend Mode This setting enables disables the ability of USB interfaces to enter suspend mode ENTER EXIT PROGRAMMING MODE USB Suspend Mode Disable USB Suspend Mode Ena...

Page 28: ...logy and data If the unit reads a label and sees the same label again within the Double Read Timeout the second read of the label will be ignored Double Read Timeout does not apply to scan modes that...

Page 29: ...d Double Read Timeout continued ENTER EXIT PROGRAMMING MODE Double Read Timeout 0 5 Second Double Read Timeout 0 6 Second Double Read Timeout 0 7 Second Double Read Timeout 0 8 Second Double Read Time...

Page 30: ...CT LABEL GONE TIMEOUT SETTING 5 Scan the appropriate three alpha numeric characters from the keypad in Appendix E Keypad representing the duration which was determined in the steps above You will hear...

Page 31: ...d Label Gone Timeout cont ENTER EXIT PROGRAMMING MODE Select Label Gone Timeout Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the be...

Page 32: ...fies the timeout value for the reader to enter low power Sleep Mode ENTER EXIT PROGRAMMING MODE Sleep Mode Timeout Disable Sleep Mode Timeout 500ms Sleep Mode Timeout 1 Second Sleep Mode Timeout 2 Sec...

Page 33: ...Sleep Mode Timeout continued ENTER EXIT PROGRAMMING MODE Sleep Mode Timeout 5 Seconds Sleep Mode Timeout 6 Seconds Sleep Mode Timeout 7 Seconds Sleep Mode Timeout 8 Seconds Sleep Mode Timeout 9 Secon...

Page 34: ...Guide 23 LED and Beeper Indicators Power On Alert Disables or enables the indication from the Beeper that the reader is receiving power ENTER EXIT PROGRAMMING MODE Power On Alert Disable No Audible I...

Page 35: ...ully reading a barcode Choices are Good Read Indicate after decode Good Read Indicate after transmit Good Read Indicate after CTS goes inactive then active NOTE This option which uses CTS is only vali...

Page 36: ...ndicators Product Reference Guide 25 Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound ENTER EXIT PROGRAMMING MODE Good Read Beep Type Mono Good Read Beep Type...

Page 37: ...or high frequency se lectable from the list below Controls the beeper s pitch tone Good Read Beep Length Specifies the duration of a good read beep ENTER EXIT PROGRAMMING MODE Good Read Beep Frequenc...

Page 38: ...Length continued ENTER EXIT PROGRAMMING MODE Good Read Beep Length 80 msec Good Read Beep Length 100 msec Good Read Beep Length 120 msec Good Read Beep Length 140 msec Good Read Beep Length 160 msec G...

Page 39: ...ep Volume Selects the beeper volume loudness upon a good read beep There are three selectable volume levels ENTER EXIT PROGRAMMING MODE Good Read Beep Volume Beeper Off Good Read Beep Volume Low Good...

Page 40: ...D DURATION SETTING 5 Scan the appropriate three digits from the keypad in Appendix E Keypad represent ing the duration which was determined in the steps above You will hear a two beep indication after...

Page 41: ...R EXIT PROGRAMMING MODE Select Good Read LED Duration Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginning CANCEL DEFAULT 020...

Page 42: ...ntil Scanning Active Time has elapsed or the trigger has been released and pulled again Double Read Timeout1 prevents undesired multiple reads of the same label while in this mode Flashing The reader...

Page 43: ...rded Scan Mode continued ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode Trigger Hold Multiple Scan Mode Trigger Pulse Multiple Scan Mode Flashing Scan Mode Always On Scan Mode Stand Mo...

Page 44: ...rigger is pulled while in Stand Mode NOTE This timeout is only used when the Scan Mode is configured as Stand Mode ENTER EXIT PROGRAMMING MODE Stand Mode Triggered Timeout 0 5 Seconds Stand Mode Trigg...

Page 45: ...D7100 Corded Stand Mode Triggered Timeout continued ENTER EXIT PROGRAMMING MODE Stand Mode Triggered Timeout 6 Seconds Stand Mode Triggered Timeout 8 Seconds Stand Mode Triggered Timeout Switch back t...

Page 46: ...t rep resent the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Program ming Mode...

Page 47: ...Active Time cont ENTER EXIT PROGRAMMING MODE Select Scanning Active Time Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginnin...

Page 48: ...n Appendix E Keypad represent ing the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to ex...

Page 49: ...ded Flash On Time cont ENTER EXIT PROGRAMMING MODE Select Flash ON Time Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginning...

Page 50: ...in Appendix E Keypad that repre sent the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to...

Page 51: ...ded Flash Off Time cont ENTER EXIT PROGRAMMING MODE Select Flash OFF Time Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginnin...

Page 52: ...nce Guide 41 Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup Choices are low medium and high ENTER EXIT PROGRAMMING MODE Stand Mode Sensitivity Low Stand Mode Sensitivity Mediu...

Page 53: ...by this feature Immediately following this the reader will start scanning NOTE The Laser Pointer is a value added option which might not have been included when your reader was ordered ENTER EXIT PRO...

Page 54: ...be activated for the time specified by Laser Pointer Control then start blinking OFF then ON at a 50 duty cycle and a repeating period set by Laser Pointer Period ENTER EXIT PROGRAMMING MODE Laser Poi...

Page 55: ...ion Specifies the duration of the good read pointer beam after a good read ENTER EXIT PROGRAMMING MODE Green Spot Duration Disable Green Spot is Off Green Spot Duration Short 300 msec Green Spot Durat...

Page 56: ...USB interfaces are available in Chapter 6 RS 232 USB Com Interfaces RS 232 Standard Factory Settings Reference Appendix B Standard Defaults for a listing of standard factory settings Baud Rate Baud ra...

Page 57: ...RS 232 ONLY Interface 46 PowerScanTM PD7100 Corded Baud Rate continued ENTER EXIT PROGRAMMING MODE Baud Rate 9600 Baud Rate 19 200 Baud Rate 38 400 Baud Rate 57 600 Baud Rate 115 200 DEFAULT...

Page 58: ...eference Guide 47 Data Bits This parameter allows the reader to interface with devices requiring a 7 bit or 8 bit ASCII protocol for sending and receiving data ENTER EXIT PROGRAMMING MODE 7 Data Bits...

Page 59: ...ion of one character and prepares the receiving device for the next character in the serial data stream The number of stop bits selected one or two depends on the number the receiving terminal is prog...

Page 60: ...ice requirements Select None when no parity bit is required Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an odd number of 1 bits are contained in the coded...

Page 61: ...CTS RTS is asserted during transmissions CTS gates transmissions RTS XON XOFF RTS is asserted during transmissions CTS is ignored XON and XOFF gate transmissions RTS On CTS RTS is always asserted CTS...

Page 62: ...SB Com Interfaces Introduction The programming barcodes in this chapter allow modifications to the standard RS 232 and USB Com interfaces Standard Factory Settings Reference Appendix B Standard Defaul...

Page 63: ...riate two digits from the keypad in Appendix E Keypad that rep resent the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER...

Page 64: ...lay cont ENTER EXIT PROGRAMMING MODE Intercharacter Delay No Delay Select Intercharacter Delay Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start...

Page 65: ...to gain a user s attention to an illegal entry or other important event Beep On Not on File This option enables disables the action of the reader to sound a three beep sequence upon receiving a Not O...

Page 66: ...label transmission The reader expects an ACK NAK response from the host when a label is sent Enable for host command acknowledge The reader will respond with ACK NAK when the host sends a command Enab...

Page 67: ...E Keypad that represent the desired character value in step 1 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Program ming Mode This...

Page 68: ...ACK NAK Options Product Reference Guide 57 ACK Character cont ENTER EXIT PROGRAMMING MODE Select ACK Character Setting DEFAULT 0x06 ACK Character...

Page 69: ...E Keypad that represent the desired character value in step 1 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Program ming Mode This...

Page 70: ...ACK NAK Options Product Reference Guide 59 NAK Character cont ENTER EXIT PROGRAMMING MODE Select NAK Character Setting DEFAULT 0x15 NAK Character...

Page 71: ...NG 5 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the duration which was determined in the steps above You will hear a two beep indication after the last charac...

Page 72: ...imeout Value cont ENTER EXIT PROGRAMMING MODE Select ACK NAK Timeout Value Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginni...

Page 73: ...pendix E Keypad that represent the number which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Pr...

Page 74: ...63 ACK NAK Retry Count cont ENTER EXIT PROGRAMMING MODE Select ACK NAK Retry Count Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the...

Page 75: ...while waiting for an ACK character from the host Options are Ignore errors detected Process error as valid ACK character Process error as valid NAK character ENTER EXIT PROGRAMMING MODE ACK NAK Error...

Page 76: ...ion Failure This option enables disables the reader s ability to sound an error beep to indicate a transmission failure while in ACK NAK mode ENTER EXIT PROGRAMMING MODE Indicate Transmission Failure...

Page 77: ...ypad in Appendix E Keypad that represent the desired character value in step 1 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Progra...

Page 78: ...Disable Character Product Reference Guide 67 Disable Character cont ENTER EXIT PROGRAMMING MODE Select Disable Character Setting DEFAULT 0x44 Disable Character is D...

Page 79: ...haracters from the keypad in Appendix E Keypad that represent the desired character value in step 2 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE b...

Page 80: ...Enable Character Product Reference Guide 69 Enable Character cont ENTER EXIT PROGRAMMING MODE Select Enable Character Setting DEFAULT 0x45 Enable Character is E...

Page 81: ...RS 232 USB Com Interfaces 70 PowerScanTM PD7100 Corded NOTES...

Page 82: ...apter to select options for USB Keyboard and Wedge Interfaces Standard Factory Settings Reference Appendix B Standard Defaults for a listing of standard factory settings Scancode Tables Information ab...

Page 83: ...yboard AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 without Alternate Key Keyboard Wedge for IBM AT PS2 without alternate key encoding but without external keyboard All other interfaces support ONLY th...

Page 84: ...ure description Country Mode France Country Mode Germany Supports only the interfaces listed in theCountry Mode feature description Country Mode Hungary Country Mode Italy Supports only the interfaces...

Page 85: ...interfaces listed in theCountry Mode feature description Country Mode Portugal Country Mode Romania Supports only the interfaces listed in theCountry Mode feature description Supports only the interf...

Page 86: ...is selected Numlock This option specifies the setting of the Numbers Lock Numlock key while in keyboard wedge interface This only applies to alternate key encoding interfaces It does not apply to USB...

Page 87: ...Ctrl Keys special keys are located from 0x80 to 0xA1 Control Character 01 Characters from 00 to 0x1F are sent as control character Ctrl Capital Key special keys are located from 0x80 to 0xA1 Control...

Page 88: ......

Page 89: ...dge Quiet Interval cont ENTER EXIT PROGRAMMING MODE Select Wedge Quiet Interval Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the be...

Page 90: ...Appendix E Keypad that rep resent the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to ex...

Page 91: ...lay cont ENTER EXIT PROGRAMMING MODE Intercharacter Delay No Delay Select Intercharacter Delay Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start...

Page 92: ...the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Program ming Mode This complet...

Page 93: ...Corded Intercode Delay cont ENTER EXIT PROGRAMMING MODE Set Intercode Delay Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginning CAN...

Page 94: ...s option specifies the USB poll rate for a USB keyboard NOTE This feature applies ONLY to the USB Keyboard interface ENTER EXIT PROGRAMMING MODE USB Keyboard Speed 1ms USB Keyboard Speed 2ms USB Keybo...

Page 95: ...nterface 84 PowerScanTM PD7100 Corded USB Keyboard Speed continued ENTER EXIT PROGRAMMING MODE USB Keyboard Speed 6ms USB Keyboard Speed 7ms USB Keyboard Speed 8ms USB Keyboard Speed 9ms USB Keyboard...

Page 96: ...reader will be connected with Use the feature settings in this chapter and Chapter 9 IBM 46XX Interface to specifically configure for the USB OEM interface Other USB interfaces are included in the ap...

Page 97: ...nners you may already have con nected to a USB OEM POS you may need to change this setting to enable all devices to communicate Options are Table Top Scanner Handheld Scanner NOTE It may be necessary...

Page 98: ...ns This setting provides for an interface specific control mechanism Options are Obey Obey Scanner Configuration Host Commands Ignore Ignore Scanner Configuration Host Commands ENTER EXIT PROGRAMMING...

Page 99: ...USB OEM Interface 88 PowerScanTM PD7100 Corded NOTES...

Page 100: ...46XX Interface Introduction Use the barcodes in this section to configure programmable features for available IBM 46XX interfaces IBM Standard Factory Settings Reference Appendix B Standard Defaults f...

Page 101: ...ive second period to allow the user to enter Programming Mode and configure the reader The con figurable range for this feature is 1 to 15 resets ENTER EXIT PROGRAMMING MODE 46xx Number of Host Resets...

Page 102: ...Guide 91 46xx Number of Host Resets cont ENTER EXIT PROGRAMMING MODE 46xx Number of Host Resets 7 46xx Number of Host Resets 8 46xx Number of Host Resets 9 46xx Number of Host Resets 10 46xx Number of...

Page 103: ...IBM 46XX Interface 92 PowerScanTM PD7100 Corded 46xx Number of Host Resets cont ENTER EXIT PROGRAMMING MODE 46xx Number of Host Resets 13 46xx Number of Host Resets 14 46xx Number of Host Resets 15...

Page 104: ...translation The data is not converted to Code 39 or verified to be valid for Code 39 Options are IBM Standard Format Send labels in standard IBM format Code 39 Format Translate the following symbologi...

Page 105: ...This setting provides for an interface specific control mechanism Options are Obey Obey Scanner Configuration Host Commands Ignore Ignore Scanner Configuration Host Commands ENTER EXIT PROGRAMMING MO...

Page 106: ...erface Wand Emulation Standard Factory Settings Reference Appendix B Standard Defaults for a listing of standard factory settings Wand Idle State This feature specifies the level of the Wand output si...

Page 107: ...the Wand output signal Choices are Quiet zones and spaces are high bars are low Quiet zones and spaces are low bars are high NOTE TTL logic levels 0V Low 0 7V 2 4V High 5 25V ENTER EXIT PROGRAMMING M...

Page 108: ...ide 97 Wand Signal Speed This feature specifies the speed of the Wand output signal per nominal bar or space Choices are 330 microseconds 660 microseconds ENTER EXIT PROGRAMMING MODE Wand Signal Speed...

Page 109: ...erted to a single symbology Options are No conversion Convert to Code 39 symbology Convert to Code 39 Full ASCII Convert to Code 128 symbology ENTER EXIT PROGRAMMING MODE Label Symbology Conversion No...

Page 110: ...interface Choices are Disable no leading trailing noise Enable leading noise Enable trailing noise Enable leading and trailing noise ENTER EXIT PROGRAMMING MODE Transmit Noise Disable Transmit Noise T...

Page 111: ...Wand Emulation Interface 100 PowerScanTM PD7100 Corded NOTES...

Page 112: ...cific symbologies Figure 3 shows the available elements you can add to a message string Figure 3 Breakdown of a Message String CAUTION It is not recommended to use these features with IBM interfaces N...

Page 113: ...position before the barcode data and or as a suffix in a position following the barcode data as indicated in Figure 4 Figure 4 Prefix and Suffix Positions Example Setting a Prefix In this example we...

Page 114: ...place the unit in Programming Mode then the Set Global Prefix or Set Global Suffix barcode followed by the digits in hex from the Alphanumeric characters in Appendix E Key pad representing your desire...

Page 115: ...ollowed by A modifier character the modifier character is symbol dependent Figure 5 AIM ID NOTE This feature enables disables addition of AIM IDs for all symbology types SYMBOLOGY CHAR SYMBOLOGY CHAR...

Page 116: ...Global AIM ID Product Reference Guide 105 Global AIM ID continued ENTER EXIT PROGRAMMING MODE Global AIM ID Disable Global AIM ID Enable DEFAULT...

Page 117: ...M ID for GS1 128 can be enabled disabled inde pendently The AIM ID for GS1 128 is a C1 C2 or C3 AIM IDs for other symbologies can be enabled disabled independently as well Contact Customer Support for...

Page 118: ...l ID Set Individually Per Symbology on page 110 If you wish to program the reader to always include an industry standard label identifier for ALL symbology types see the pre vious feature Global AIM I...

Page 119: ...540000 CODE32 A 410000 X 580000 CODE39 2A0000 V 560000 CODE4 4 340000 4 340000 CODE5 j 6A0000 j 6A0000 CODE93 260000 U 550000 DATALOGIC 2OF5 s 730000 s 730000 EAN13 F 460000 B 420000 EAN13 P2 F 460000...

Page 120: ...50000 e 650000 ISBN I 490000 400000 ISBT128 f 660000 f 660000 ISSN n 6E0000 n 6E0000 MSI 400000 Z 5A0000 Plessey a 610000 a 610000 S25 s 730000 P 500000 UPCA A 410000 C 430000 UPCA P2 A 410000 F 46000...

Page 121: ...y 5 Turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID For example if you wish to select an equal sign as a Labe...

Page 122: ...ction starting on page 113 GS1 DataBar Omnidirectional Code 39 Interleaved 2 of 5 Code 32 4 Custom Label ID example desired characters D B C 3 P H 5 Find hex equivalents from the ASCII table inside ba...

Page 123: ...d or sent as a prefix or suffix for a given symbology type ENTER EXIT PROGRAMMING MODE Label ID Transmission Disable Label ID Transmission Enable as Prefix Label ID Transmission Enable as Suffix CANCE...

Page 124: ...for which a Label ID is to be configured See Label ID on page 107 for full instructions ENTER EXIT PROGRAMMING MODE Set UPC A Label ID Character s Set UPC A P2 Label ID Character s Set UPC A P5 Label...

Page 125: ...y for which a Label ID is to be configured See Label ID on page 107 for full instructions ENTER EXIT PROGRAMMING MODE Set UPC E P5 Label ID Character s Set UPC E GS1 128 Label ID Character s Set EAN 1...

Page 126: ...ology for which a Label ID is to be configured See Label ID on page 107 for full instructions ENTER EXIT PROGRAMMING MODE Set EAN 8 Label ID Character s Set EAN 8 P2 Label ID Character s Set EAN 8 P5...

Page 127: ...bel ID is to be configured See Label ID on page 107 for full instructions ENTER EXIT PROGRAMMING MODE Set GTIN P5 Label ID Character s Set GTIN GS1 128 Label ID Character s Set GS1 DataBar Omnidirecti...

Page 128: ...configured See Label ID on page 107 for full instructions ENTER EXIT PROGRAMMING MODE Set Code 32 Label ID Character s Set Code 39 CIP Label ID Character s Set Code 128 Label ID Character s Set GS1 12...

Page 129: ...for which a Label ID is to be configured See Label ID on page 107 for full instructions ENTER EXIT PROGRAMMING MODE Set Codabar Label ID Character s Set ABC Codabar Label ID Character s Set Code 11 L...

Page 130: ...for which a Label ID is to be configured See Label ID on page 107 for full instructions ENTER EXIT PROGRAMMING MODE Set IATA Label ID Character s Set Concatinated ISBT 128 Label ID Character s Set MS...

Page 131: ...nued This option selects the symbology for which a Label ID is to be configured See Label ID on page 107 for full instructions ENTER EXIT PROGRAMMING MODE Set Codablock F Label ID Character s Set Code...

Page 132: ...ir is FF then no conversion is done For example if you have the character conversion configuration item set to the following 41423132FFFFFFFF The first pair is 4142 or AB 41 hex is an ASCII capital A...

Page 133: ...the above example Next turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits needed to fulfill the string 4 Turn to Appendix E Keypad and scan the barcode...

Page 134: ...widely used set of standard fac tory settings That section also provides space to record any custom settings needed or implemented for your system UPC A Datalogic 2 of 5 UPC E Codabar GTIN Formatting...

Page 135: ...Symbologies 124 PowerScanTM PD7100 Corded Disable All Symbologies Scan this label to disable all symbologies ENTER EXIT PROGRAMMING MODE Disable all symbologies...

Page 136: ...ables only GS1 DataBar coupon decoding To set this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused barcodes on this and the facing...

Page 137: ...reader will not read UPC A barcodes UPC A Check Character Transmission Enable this option to transmit the check character along with UPC A barcode data ENTER EXIT PROGRAMMING MODE UPC A Disable UPC A...

Page 138: ...to match those required for EAN 13 UPC A Number System Character Transmission This feature enables disables transmission of the UPC A number system character ENTER EXIT PROGRAMMING MODE UPC A to EAN 1...

Page 139: ...fore it is accepted as good read In store labels are defined as UPC A labels with a number system character of 2 or 4 as well as EAN 8 and EAN 13 labels with a Flag1 character of 2 or an EAN 13 label...

Page 140: ...der will not read UPC E barcodes UPC E Check Character Transmission Enable this option to transmit the check character along with UPC E barcode data ENTER EXIT PROGRAMMING MODE UPC E Disable UPC E Ena...

Page 141: ...ecting this feature also changes the symbology ID to match those required for EAN 13 Expand UPC E to UPC A Expands UPC E data to the UPC A data format ENTER EXIT PROGRAMMING MODE UPC E to EAN 13 Don t...

Page 142: ...UPC E Number System Character Transmission This feature enables disables transmission of the UPC E system number character ENTER EXIT PROGRAMMING MODE UPC E Number System Character Do not transmit UP...

Page 143: ...imum Reads This feature specifies the minimum number of consecutive times a UPC E label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE UPC E Minimum Reads 1 UPC E Minim...

Page 144: ...PC E UPC A EAN 8 and EAN 13 labels into the GTIN 14 character format NOTE If add on information is present on the base label prior to the conver sion taking place the addon information will be appende...

Page 145: ...eader will not read EAN 13 JAN 13 barcodes EAN 13 Check Character Transmission Enable this option to transmit the check character along with EAN 13 barcode data ENTER EXIT PROGRAMMING MODE EAN 13 Disa...

Page 146: ...nt EAN 13 Flag 1 Character Enables disables transmission of an EAN JAN13 Flag1 character The Flag 1 character is the first character of the label ENTER EXIT PROGRAMMING MODE EAN 13 Flag 1 Char Don t t...

Page 147: ...okland labels starting with 978 to ISBN labels ISSN Enable Disable Enables disables conversion of EAN JAN13 Bookland labels starting with 977 to ISSN labels ENTER EXIT PROGRAMMING MODE EAN 13 ISBN Con...

Page 148: ...eads This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE EAN 13 Minimum Reads 1 EAN 13 Minimum...

Page 149: ...reader will not read EAN 8 JAN 8 barcodes EAN 8 Check Character Transmission Enable this option to transmit the check character along with EAN 8 barcode data ENTER EXIT PROGRAMMING MODE EAN 8 Disable...

Page 150: ...eference Guide 139 EAN 8 cont Expand EAN 8 to EAN 13 Enable this option to expand EAN 8 JAN 8 labels to EAN 13 JAN 13 ENTER EXIT PROGRAMMING MODE Expand EAN 8 to EAN 13 Disable Expand EAN 8 to EAN 13...

Page 151: ...Reads This feature specifies the minimum number of consecutive times an EAN 8 Jan 8 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE EAN 8 Minimum Reads 1 EAN 8 Mi...

Page 152: ...oder This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors Choosing Level 3 which is the default setting allows t...

Page 153: ...7100 Corded UPC EAN Global Settings cont UPC EAN Decoding Level cont ENTER EXIT PROGRAMMING MODE UPC EAN Decoding Level 1 UPC EAN Decoding Level 2 UPC EAN Decoding Level 3 UPC EAN Decoding Level 4 UPC...

Page 154: ...that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will also increase the chances that a label will be read incorrectly UPC EAN Reconstruction...

Page 155: ...lculation Enable 5 digit price weight check digit calculation Enable European 4 digit price weight check digit calculation Enable European 5 digit price weight check digit calculation ENTER EXIT PROGR...

Page 156: ...cont UPC A Minimum Reads This feature specifies the minimum number of consecutive times a UPC A label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE UPC A Minimum Reads...

Page 157: ...nal and conditional add ons NOTE If a UPC EAN base label and a an add on are both decoded the reader will transmit the base label and add on If a UPC EAN base label is decoded without an add on the ba...

Page 158: ...Add Ons Product Reference Guide 147 Add Ons cont Optional Add ons cont ENTER EXIT PROGRAMMING MODE Optional Add Ons Enable P5 Optional Add Ons Disable GS1 128 Optional Add Ons Enable GS1 128 DEFAULT...

Page 159: ...er will look for an add on when an add on fragment has been seen and optional add ons are enabled Also see Optional GS1 128 Add On Timer on page 151 ENTER EXIT PROGRAMMING MODE Optional Add on Timer 1...

Page 160: ...Ons cont Optional Add On Timer cont ENTER EXIT PROGRAMMING MODE Optional Add on Timer 60ms Optional Add on Timer 70ms Optional Add on Timer 100ms Optional Add on Timer 120ms Optional Add on Timer 140...

Page 161: ...t Optional Add On Timer cont ENTER EXIT PROGRAMMING MODE Optional Add on Timer 180ms Optional Add on Timer 200ms Optional Add on Timer 220ms Optional Add on Timer 240ms Optional Add on Timer 260ms Opt...

Page 162: ...the linear EAN UPC part For UPC EAN add ons other than those of that type see Optional Add On Timer on page 148 ENTER EXIT PROGRAMMING MODE Optional GS1 128 Add On Timer Disable Optional GS1 128 Add O...

Page 163: ...1 128 Add On Timer cont ENTER EXIT PROGRAMMING MODE Optional GS1 128 Add On Timer 60ms Optional GS1 128 Add On Timer 70ms Optional GS1 128 Add On Timer 100ms Optional GS1 128 Add On Timer 120ms Option...

Page 164: ...t ENTER EXIT PROGRAMMING MODE Optional GS1 128 Add On Timer 180ms Optional GS1 128 Add On Timer 200ms Optional GS1 128 Add On Timer 220ms Optional GS1 128 Add On Timer 240ms Optional GS1 128 Add On Ti...

Page 165: ...is feature specifies the minimum number of times a P2 add on must be read before it is marked as valid and then combined with a base label ENTER EXIT PROGRAMMING MODE P2 Add Ons Minimum Reads 1 P2 Add...

Page 166: ...feature specifies the minimum number of times a P5 add on must be read before it is marked as valid and then combined with a base label ENTER EXIT PROGRAMMING MODE P5 Add Ons Minimum Reads 1 P5 Add On...

Page 167: ...specifies the minimum number of times an GS1 128 add on must be read before it is marked as valid and then combined with a base label ENTER EXIT PROGRAMMING MODE GS1 128 Add Ons Minimum Reads 1 GS1 12...

Page 168: ...ll not read GS1 DataBar Omnidirectional barcodes GS1 DataBar Omnidirectional GS1 128 Emulation When enabled GS1 DataBar Omnidirectional barcodes will be translated to the GS1 128 label data format ENT...

Page 169: ...the minimum number of consecutive times a GS1 DataBar Omni directional label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE GS1 DataBar Omnidirectional Minimum Reads 1...

Page 170: ...the reader will not read GS1 DataBar Expanded barcodes GS1 DataBar Expanded GS1 128 Emulation When enabled GS1 DataBar Expanded barcodes will be translated to the GS1 128 label data format ENTER EXIT...

Page 171: ...e specifies the minimum number of consecutive times a GS1 DataBar Ex panded label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE GS1 DataBar Expanded Minimum Reads 1 GS...

Page 172: ...th decoding or fixed length decoding for the GS1 DataBar Expanded symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two differen...

Page 173: ...AR EXPANDED LENGTH 1 SET TING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps above You will hear a two beep...

Page 174: ...GS1 DataBar Expanded Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select GS1 DataBar Expanded Set Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You c...

Page 175: ...the barcode SELECT GS1 DATABAR EXPANDED LENGTH 2 SET TING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps a...

Page 176: ...GS1 DataBar Expanded Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select GS1 DataBar Expanded Set Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You ca...

Page 177: ...e reader will not read GS1 DataBar Limited barcodes GS1 DataBar Limited GS1 128 Emulation When enabled GS1 DataBar Limited barcodes will be translated to the GS1 128 label data format ENTER EXIT PROGR...

Page 178: ...feature specifies the minimum number of consecutive times a GS1 DataBar Limited label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE GS1 DataBar Limited Minimum Reads 1...

Page 179: ...nTM PD7100 Corded Code 39 The following options apply to the Code 39 symbology Code 39 Enable Disable When disabled the reader will not read Code 39 barcodes ENTER EXIT PROGRAMMING MODE Code 39 Disabl...

Page 180: ...led any check character in the label is treated as a data char acter ENTER EXIT PROGRAMMING MODE Code 39 Check Character Calculation Don t Calculate Code 39 Check Character Calculation Calculate Std C...

Page 181: ...t Stop Character Transmission Enable this option to enable disable transmission of Code 39 start and stop characters ENTER EXIT PROGRAMMING MODE Code 39 Check Character Transmission Don t Send Code 39...

Page 182: ...Code 39 cont Code 39 Full ASCII In Code 39 decoding this enables disables the translation of Code 39 characters to Code 39 full ASCII characters ENTER EXIT PROGRAMMING MODE Code 39 Full ASCII Disable...

Page 183: ...areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label ENTER EXIT PROGRAMMING MODE Code 39 Quiet Zones Quiet Zone on one side Code 39 Quiet Zon...

Page 184: ...eads This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Code 39 Minimum Reads 1 Code 39 Minim...

Page 185: ...d of decoding errors Choosing Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change the decoding level for a par...

Page 186: ...erence Guide 175 Code 39 cont Code 39 Decoding Level cont ENTER EXIT PROGRAMMING MODE Code 39 Decoding Level 1 Code 39 Decoding Level 2 Code 39 Decoding Level 3 Code 39 Decoding Level 4 Code 39 Decodi...

Page 187: ...coding or fixed length decoding for the Code 39 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different leng...

Page 188: ...1 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps above You will hear a two beep indication after t...

Page 189: ...Code 39 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Code 39 Set Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the...

Page 190: ...MODE barcode to enter Program ming Mode 3 Scan the barcode SELECT CODE 39 LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting whi...

Page 191: ...nt Code 39 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Code 39Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the be...

Page 192: ...specifies the ratio between an intercharacter space and module for Code 39 labels ENTER EXIT PROGRAMMING MODE Code 39 Interdigit Ratio Disable Code 39 Interdigit Ratio 1 Code 39 Interdigit Ratio 2 Co...

Page 193: ...nTM PD7100 Corded Code 39 cont Code 39 Interdigit Ratio cont ENTER EXIT PROGRAMMING MODE Code 39 Interdigit Ratio 6 Code 39 Interdigit Ratio 7 Code 39 Interdigit Ratio 8 Code 39 Interdigit Ratio 9 Cod...

Page 194: ...scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will also increa...

Page 195: ...els When parts of a Code 39 bar code are presented to the reader with this feature enabled the barcode parts will be as sembled by the reader s software and the data will be decoded if all barcode pro...

Page 196: ...ill not read Code 32 barcodes Code 32 Feature Setting Exceptions ENTER EXIT PROGRAMMING MODE Code 32 Disable Code 32 Enable DEFAULT NOTE The following features are set for Code 32 by using these Code...

Page 197: ...ata Code 32 Start Stop Character Transmission This option enables disable transmission of Code 32 start and stop characters ENTER EXIT PROGRAMMING MODE Code 32 Check Character Transmission Don t Send...

Page 198: ...ble Disable Enables Disables ability of the reader to decode Code 39 CIP labels Code 128 The following options apply to the Code 128 symbology Code 128 Enable Disable When disabled the reader will not...

Page 199: ...labels Code 128 Check Character Transmission Enable this option to transmit the check character along with Code 128 barcode data ENTER EXIT PROGRAMMING MODE Code 128 to Code 39 Don t Expand Code 128 t...

Page 200: ...Change Transmission Enables disables the transmission of Sub Code exchange characters NOT transmitted by standard decoding ENTER EXIT PROGRAMMING MODE Code 128 Function Character Transmission Don t Se...

Page 201: ...e blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label ENTER EXIT PROGRAMMING MODE Code 128 Quiet Zones No Quiet Zones Code 128 Quiet Zo...

Page 202: ...ads This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Code 128 Minimum Reads 1 Code 128 Min...

Page 203: ...nse of increasing the likelihood of decoding errors Choosing Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to chan...

Page 204: ...nce Guide 193 Code 128 cont Code 128 Decoding Level cont ENTER EXIT PROGRAMMING MODE Code 128 Decoding Level 1 Code 128 Decoding Level 2 Code 128 Decoding Level 3 Code 128 Decoding Level 4 Code 128 De...

Page 205: ...coding or fixed length decoding for the Code 128 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different len...

Page 206: ...TH 1 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps above You will hear a two beep indication after...

Page 207: ...Code 128 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Code 128 Set Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at t...

Page 208: ...Mode 3 Scan the barcode SELECT CODE 128 LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps abo...

Page 209: ...t Code 128 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Code 128 Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the...

Page 210: ...scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will also increa...

Page 211: ...128 labels When parts of a Code 128 barcode are presented to the reader with this feature enabled the barcode parts will be assembled by the reader s software and the data will be decoded if all barc...

Page 212: ...sables the ability of the reader to translate GS1 128 labels to the GS1 128 data format Options are Transmit GS1 128 labels in Code 128 data format Transmit GS1 128 labels in GS1 128 data format Do no...

Page 213: ...rded Interleaved 2 of 5 I 2 of 5 The following options apply to the I 2 of 5 symbology I 2 of 5 Enable Disable When disabled the reader will not read I 2 of 5 barcodes ENTER EXIT PROGRAMMING MODE I 2...

Page 214: ...optional I 2 of 5 check character ENTER EXIT PROGRAMMING MODE I 2 of 5 Check Character Calculation Disable I 2 of 5 Check Character Calculation Check Standard Modulo 10 I 2 of 5 Check Character Calcul...

Page 215: ...Check Character Transmission Enable this option to transmit the check character along with I 2 of 5 barcode data ENTER EXIT PROGRAMMING MODE I 2 of 5 Check Character Calculation Check Italian Post EN...

Page 216: ...2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an I 2 of 5 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE I 2 of 5 Minimum R...

Page 217: ...oding errors Choosing Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change the decoding level for a particular...

Page 218: ...Reference Guide 207 Interleaved 2 of 5 I 2 of 5 cont 2 of 5 Decoding Level cont ENTER EXIT PROGRAMMING MODE 2 of 5 Decoding Level 1 2 of 5 Decoding Level 2 2 of 5 Decoding Level 3 2 of 5 Decoding Leve...

Page 219: ...length decoding or fixed length decoding for the I 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two diff...

Page 220: ...de SELECT I 2 of 5 LENGTH 1 SETTING 5 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps above You will hear a tw...

Page 221: ...5 cont Datalogic 2 of 5 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select I 2 of 5 Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start...

Page 222: ...Program ming Mode 4 Scan the barcode SELECT I 2 of 5 LENGTH 2 SETTING 5 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in...

Page 223: ...2 of 5 cont I 2 of 5 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select I 2 of 5 Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start aga...

Page 224: ...data from multiple scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlati...

Page 225: ...for I 2 of 5 labels When parts of a I 2 of 5 barcode are presented to the reader with this feature enabled the barcode parts will be assembled by the reader s software and the data will be decoded if...

Page 226: ...of reader to decode Interleaved 2 of 5 CIP HR labels Datalogic 2 of 5 The following options apply to the Datalogic 2 of 5 symbology Datalogic 2 of 5 Enable Disable When disabled the reader will not re...

Page 227: ...5 Check Character Calculation This option enables disables calculation and verification of an optional Datalogic 2 of 5 check character ENTER EXIT PROGRAMMING MODE Datalogic 2 of 5 Check Character Ca...

Page 228: ...ive times an Datalogic 2 of 5 la bel must be decoded before it is accepted as good read Datalogic 2 of 5 Decoding Level ENTER EXIT PROGRAMMING MODE I 2 of 5 Minimum Reads 1 I 2 of 5 Minimum Reads 2 I...

Page 229: ...ng or fixed length decoding for the Datalogic 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different...

Page 230: ...I 2 of 5 LENGTH 1 SETTING 5 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps above You will hear a two beep ind...

Page 231: ...atalogic 2 of 5 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Datalogic 2 of 5 Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start...

Page 232: ...Mode 4 Scan the barcode SELECT Datalogic 2 of 5 LENGTH 2 SETTING 5 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the s...

Page 233: ...talogic 2 of 5 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Datalogic 2 of 5 Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start a...

Page 234: ...intercharacter space and module for Datalogic 2 of 5 ENTER EXIT PROGRAMMING MODE Datalogic 2 of 5 Interdigit Maximum Ratio Disable Datalogic 2 of 5 Interdigit Maximum Ratio 1 Datalogic 2 of 5 Interdig...

Page 235: ...f 5 Interdigit Maximum Ratio cont Datalogic 2 of 5 Interdigit Maximum Ratio 6 Datalogic 2 of 5 Interdigit Maximum Ratio 7 Datalogic 2 of 5 Interdigit Maximum Ratio 8 Datalogic 2 of 5 Interdigit Maximu...

Page 236: ...rom multiple scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will...

Page 237: ...f 5 labels When parts of a Data logic 2 of 5 barcode are presented to the reader with this feature enabled the barcode parts will be assembled by the reader s software and the data will be decoded if...

Page 238: ...ence Guide 227 Codabar The following options apply to the Codabar symbology Codabar Enable Disable When disabled the reader will not read Codabar barcodes ENTER EXIT PROGRAMMING MODE Codabar Disable C...

Page 239: ...erification of an optional Codabar check character When disabled any check character in the label is treated as a data character ENTER EXIT PROGRAMMING MODE Codabar Check Character Calculation Don t C...

Page 240: ...top Character Transmission Enable this option to enable disable transmission of Codabar start and stop characters ENTER EXIT PROGRAMMING MODE Codabar Check Character Transmission Don t Send Codabar Ch...

Page 241: ...racter Set This option specifies the format of transmitted Codabar start stop characters ENTER EXIT PROGRAMMING MODE Codabar Check Character Set ABCD TN E Codabar Check Character Set ABCD ABCD Codabar...

Page 242: ...t Codabar Start Stop Character Match When enabled this option requires that start and stop characters match ENTER EXIT PROGRAMMING MODE Codabar Start Stop Character Match Don t Require Match Codabar S...

Page 243: ...areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label ENTER EXIT PROGRAMMING MODE Codabar Quiet Zones Quiet Zone on one side Codabar Quiet Zon...

Page 244: ...eads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Codabar Minimum Reads 1 Codabar Minim...

Page 245: ...se of increasing the likelihood of decoding errors Choosing Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to chang...

Page 246: ...erence Guide 235 Codabar cont Codabar Decoding Level cont ENTER EXIT PROGRAMMING MODE Codabar Decoding Level 1 Codabar Decoding Level 2 Codabar Decoding Level 3 Codabar Decoding Level 4 Codabar Decodi...

Page 247: ...coding or fixed length decoding for the Codabar symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different leng...

Page 248: ...ELECT CODABAR LENGTH 1 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps above You will hear a two bee...

Page 249: ...nt Codabar Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Codabar Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the b...

Page 250: ...o enter Program ming Mode 3 Scan the barcode SELECT CODABAR LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determi...

Page 251: ...nt Codabar Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select CodabarLength 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the be...

Page 252: ...specifies the ratio between an intercharacter space and module for Codabar labels ENTER EXIT PROGRAMMING MODE Codabar Interdigit Ratio Disable Codabar Interdigit Ratio 1 Codabar Interdigit Ratio 2 Co...

Page 253: ...nTM PD7100 Corded Codabar cont Codabar Interdigit Ratio cont ENTER EXIT PROGRAMMING MODE Codabar Interdigit Ratio 6 Codabar Interdigit Ratio 7 Codabar Interdigit Ratio 8 Codabar Interdigit Ratio 9 Cod...

Page 254: ...scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will also increa...

Page 255: ...els When parts of a Codabar bar code are presented to the reader with this feature enabled the barcode parts will be as sembled by the reader s software and the data will be decoded if all barcode pro...

Page 256: ...bles Disables ability of reader to decode ABC Codabar labels ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynamic ENTER EXIT PROGRAMMING MODE ABC Codabar Disable...

Page 257: ...Dynamic Con catenation Mode ENTER EXIT PROGRAMMING MODE ABC Codabar Dynamic Concatenation Timeout 50 msec ABC Codabar Dynamic Concatenation Timeout 100 msec ABC Codabar Dynamic Concatenation Timeout...

Page 258: ...uide 247 ABC Codabar cont ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated ENTER EXIT PROGRAMMING MODE ABC Codabar Force Concatenation Disable ABC Codabar For...

Page 259: ...nTM PD7100 Corded Code 11 The following options apply to the Code 11 symbology Code 11 Enable Disable When disabled the reader will not read Code 11 barcodes ENTER EXIT PROGRAMMING MODE Code 11 Disabl...

Page 260: ...ables disables calculation and verification of optional Code 11 check char acter ENTER EXIT PROGRAMMING MODE Code 11 Check Character Calculation Disable Code 11 Check Character Calculation Check C Cod...

Page 261: ...cont Code 11 Check Character Transmission This feature enables disables transmission of an optional Code 11 check character ENTER EXIT PROGRAMMING MODE Code 11 Check Character Transmission Don t Send...

Page 262: ...eads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Code 11 Minimum Reads 1 Code 11 Minim...

Page 263: ...coding or fixed length decoding for the Code 11 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different leng...

Page 264: ...G 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps above You will hear a two beep indication after the last c...

Page 265: ...Code 11 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Code 11 Set Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the...

Page 266: ...n the barcode SELECT CODE 11 LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps above You will...

Page 267: ...nt Code 11 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Code 11 Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the b...

Page 268: ...specifies the ratio between an intercharacter space and module for Code 11 labels ENTER EXIT PROGRAMMING MODE Code 11 Interdigit Ratio Disable Code 11 Interdigit Ratio 1 Code 11 Interdigit Ratio 2 Co...

Page 269: ...nTM PD7100 Corded Code 11 cont Code 11 Interdigit Ratio cont ENTER EXIT PROGRAMMING MODE Code 11 Interdigit Ratio 6 Code 11 Interdigit Ratio 7 Code 11 Interdigit Ratio 8 Code 11 Interdigit Ratio 9 Cod...

Page 270: ...reasing the likelihood of decoding errors Choosing Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change the dec...

Page 271: ...canTM PD7100 Corded Code 11 cont Code 11 Decoding Level cont ENTER EXIT PROGRAMMING MODE Codabar Decoding Level 1 Codabar Decoding Level 2 Codabar Decoding Level 3 Codabar Decoding Level 4 Codabar Dec...

Page 272: ...scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will also increa...

Page 273: ...els When parts of a Code 11 bar code are presented to the reader with this feature enabled the barcode parts will be as sembled by the reader s software and the data will be decoded if all barcode pro...

Page 274: ...ard 2 of 5 The following options apply to the Standard 2 of 5 symbology Standard 2 of 5 Enable Disable When disabled the reader will not read Standard 2 of 5 barcodes ENTER EXIT PROGRAMMING MODE Stand...

Page 275: ...andard 2 of 5 Check Character Transmission This feature enables disables transmission of an optional Standard 2 of 5 check character ENTER EXIT PROGRAMMING MODE Standard 2 of 5 Check Character Calcula...

Page 276: ...tandard 2 of 5 label must be decoded before it is accepted as good read Standard 2 of 5 Decoding Level ENTER EXIT PROGRAMMING MODE Standard 2 of 5 Minimum Reads 1 Standard 2 of 5 Minimum Reads 2 Stand...

Page 277: ...ng or fixed length decoding for the Standard 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different...

Page 278: ...RD 2 OF 5 LENGTH 1 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps above You will hear a two beep in...

Page 279: ...tandard 2 of 5 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Standard 2 of 5 Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start ag...

Page 280: ...Scan the barcode SELECT STANDARD 2 OF 5 LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps ab...

Page 281: ...tandard 2 of 5 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Standard 2 of 5 Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start ag...

Page 282: ...iple scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will also in...

Page 283: ...When parts of a Stan dard 2 of 5 barcode are presented to the reader with this feature enabled the barcode parts will be assembled by the reader s software and the data will be decoded if all bar code...

Page 284: ...ode Industrial 2 of 5 labels Industrial 2 of 5 Check Character Calculation Enables Disables calculation and verification of an optional Industrial 2 of 5 check char acter ENTER EXIT PROGRAMMING MODE I...

Page 285: ...t Industrial 2 of 5 Check Character Transmission Enables disables transmission of an Industrial 2 of 5 check character ENTER EXIT PROGRAMMING MODE Industrial 2 of 5 Check Character Transmission Disabl...

Page 286: ...h decoding or fixed length decoding for the In dustrial 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two...

Page 287: ...2 of 5 LENGTH 1 SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above You will hear a two beep indi...

Page 288: ...ndustrial 2 of 5 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Industrial 2 of 5 Set Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then...

Page 289: ...ING MODE barcode to enter Programming Mode 3 Scan the barcode SELECT INDUSTRIAL 2 OF 5 LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the leng...

Page 290: ...Industrial 2 of 5 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Industrial 2 of5 Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then star...

Page 291: ...ture specifies the minimum number of consecutive times an Industrial 2 of 5 la bel must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Industrial 2 of 5 Minimum Reads 1 Indu...

Page 292: ...ial 2 of 5 Industrial 2 of 5 Character Correlation Enable disables character correlation for Industrial 2 of 5 ENTER EXIT PROGRAMMING MODE Industrial 2 of 5 Stitching Disable Industrial 2 of 5 Stitchi...

Page 293: ...of the reader to decode IATA labels IATA Check Character Transmission Enables Disables calculation and verification of an optional Industrial 2 of 5 check char acter ENTER EXIT PROGRAMMING MODE IATA D...

Page 294: ...8 The following options apply to the ISBT 128 symbology ISBT 128 Concatenation Use this option to enable disable ISBT128 concatenation of 2 labels ENTER EXIT PROGRAMMING MODE ISBN 128 Concatenation Di...

Page 295: ...ncatenation Mode Specifies the concatenation mode between Static and Dynamic NOTE This option is only valid when ISBT 128 Concatenation is enabled see page 283 ENTER EXIT PROGRAMMING MODE ISBT 128 Con...

Page 296: ...nation Mode ENTER EXIT PROGRAMMING MODE ISBT 128 Dynamic Concatenation Timeout 50 msec ISBT 128 Dynamic Concatenation Timeout 100 msec ISBT 128 Dynamic Concatenation Timeout 200 msec ISBT 128 Dynamic...

Page 297: ...nced Concatenation Options NOTE This option is only valid when ISBT 128 Concatenation is enabled see page 283 ENTER EXIT PROGRAMMING MODE ISBT 128 Force Concatenation Disable ISBT 128 Force Concatenat...

Page 298: ...ct Reference Guide 287 MSI The following options apply to the MSI symbology MSI Enable Disable Enables Disables ability of reader to decode MSI labels ENTER EXIT PROGRAMMING MODE MSI Disable MSI Enabl...

Page 299: ...Disables calculation and verification of an optional MSI check character ENTER EXIT PROGRAMMING MODE MSI Check Character Calculation Disable MSI Check Character Calculation Enable Mod10 MSI Check Cha...

Page 300: ...fixed length decoding for the MSI symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be se...

Page 301: ...TING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above You will hear a two beep indi cation after the l...

Page 302: ...SI Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select MSI Set Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginning...

Page 303: ...ODE barcode to enter Programming Mode 3 Scan the barcode SELECT MSI LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which wa...

Page 304: ...MSI Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select MSI Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginning CA...

Page 305: ...inimum Reads This feature specifies the minimum number of consecutive times an MSI label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE MSI Minimum Reads 1 MSI Minimum...

Page 306: ...ng Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change the decoding level for a particular symbology These fac...

Page 307: ...Symbologies 296 PowerScanTM PD7100 Corded MSI cont MSI Decoding Level cont MSI Decoding Level 3 MSI Decoding Level 4 MSI Decoding Level 5 DEFAULT...

Page 308: ...ce Guide 297 Plessey The following options apply to the Plessey symbology Plessey Enable Disable Enables Disables ability of reader to decode Plessey labels ENTER EXIT PROGRAMMING MODE Plessey Disable...

Page 309: ...nal Plessey check character ENTER EXIT PROGRAMMING MODE Plessey Check Character Calculation Disable Plessey Check Character Calculation Enable Plessey std check char verification Plessey Check Charact...

Page 310: ...ixed length decoding for the Plessey symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be...

Page 311: ...SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above You will hear a two beep indi cation after t...

Page 312: ...lessey Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Plessey Set Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the b...

Page 313: ...ODE barcode to enter Programming Mode 3 Scan the barcode SELECT PLESSEY LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting whic...

Page 314: ...Plessey Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Plessey Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the begi...

Page 315: ...m Reads This feature specifies the minimum number of consecutive times a Plessey label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Plessey Minimum Reads 1 Plessey Mi...

Page 316: ...ng Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change the decoding level for a particular symbology These fac...

Page 317: ...y Decoding Level cont Plessey Stitching Enables disables fixed length stitching for Plessey Plessey Decoding Level 3 Plessey Decoding Level 4 Plessey Decoding Level 5 DEFAULT ENTER EXIT PROGRAMMING MO...

Page 318: ...sey Code 93 The following options apply to the Code 93 symbology Code 93 Enable Disable Enables Disables ability of reader to decode Code 93 labels ENTER EXIT PROGRAMMING MODE Plessey Character Correl...

Page 319: ...calculation and verification of an optional Code 93 check character ENTER EXIT PROGRAMMING MODE Code 93 Check Character Calculation Disable Code 93 Check Character Calculation Enable Check C Code 93...

Page 320: ...g or fixed length decoding for the Code 93 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths m...

Page 321: ...SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above You will hear a two beep indi cation after t...

Page 322: ...ode 93 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Code 93 Set Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the b...

Page 323: ...ODE barcode to enter Programming Mode 3 Scan the barcode SELECT CODE 93 LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting whic...

Page 324: ...Code 93 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Code 93 Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the begi...

Page 325: ...m Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Code 93 Minimum Reads 1 Code 93 Mi...

Page 326: ...ng Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change the decoding level for a particular symbology These fac...

Page 327: ...Symbologies 316 PowerScanTM PD7100 Corded Code 93 cont Code 93 Decoding Level cont Code 93 Decoding Level 3 Code 93 Decoding Level 4 Code 93 Decoding Level 5 DEFAULT...

Page 328: ...sables fixed length stitching for Code 93 ENTER EXIT PROGRAMMING MODE Code 93 Quiet Zones No Quiet Zones Code 93 Quiet Zones Quiet Zone on one side Code 93 Quiet Zones Quiet Zones on two sides Code 93...

Page 329: ...ength stitching for Code 93 Code 93 Character Correlation Enables disables Character Correlation for Code 93 ENTER EXIT PROGRAMMING MODE Code 93 Stitching Disable Code 93 Stitching Enable DEFAULT ENTE...

Page 330: ...odablock F The following options apply to the Codablock F symbology Codablock F Enable Disable Enables Disables the ability of the imager to decode Codablock F labels ENTER EXIT PROGRAMMING MODE Codab...

Page 331: ...N subtype code with FNC1 in the first position Codablock F AIM Check Specifies if Check Digit calculation algorithm is AIM compliant or not ENTER EXIT PROGRAMMING MODE Codablock F EAN Disable Codabloc...

Page 332: ...th decoding or fixed length decoding for the Codablock F symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two diffe...

Page 333: ...SETTING 4 Scan the appropriate three digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above You will hear a two beep indi cation after...

Page 334: ...Codablock F Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Codablock F Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at...

Page 335: ...barcode to enter Programming Mode 3 Scan the barcode SELECT CODABLOCK F LENGTH 2 SETTING 4 Scan the appropriate three digits from the keypad in the Keypad Appendix that represent the length setting wh...

Page 336: ...odablock F Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Codablock F Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at t...

Page 337: ...anTM PD7100 Corded Code 4 The following options apply to the Code 4 symbology Code 4 Enable Disable Enables Disables ability of imager to decode Code 4 labels ENTER EXIT PROGRAMMING MODE Code 4 Disabl...

Page 338: ...de 4 Hex to Decimal Conversion This feature enables disables the conversion of hexidecimal label data to decimal label da ta ENTER EXIT PROGRAMMING MODE Code 4 Check Character Transmission Don t Send...

Page 339: ...anTM PD7100 Corded Code 5 The following options apply to the Code 5 symbology Code 5 Enable Disable Enables Disables ability of imager to decode Code 5 labels ENTER EXIT PROGRAMMING MODE Code 5 Disabl...

Page 340: ...de 5 Hex to Decimal Conversion This feature enables disables the conversion of hexidecimal label data to decimal label da ta ENTER EXIT PROGRAMMING MODE Code 5 Check Character Transmission Don t Send...

Page 341: ...ged labels at the expense of increasing the likelihood of decoding errors Choosing Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that...

Page 342: ...Code 5 Common Configuration Items cont Code 4 and 5 Decoding Level cont ENTER EXIT PROGRAMMING MODE Code 4 and Code 5 Decoding Level 1 Code 4 and Code 5 Decoding Level 2 Code 4 and Code 5 Decoding Le...

Page 343: ...um Reads This feature specifies the minimum number of consecutive times a Code 4 or Code 5 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Code 4 or Code 5 Minimum...

Page 344: ...tt 2 of 5 The following options apply to the Follett 2 of 5 symbology Follett 2 of 5 Enable Disable Enables Disables ability of imager to decode Follett 2 of 5 labels ENTER EXIT PROGRAMMING MODE Folle...

Page 345: ...Symbologies 334 PowerScanTM PD7100 Corded NOTES...

Page 346: ...Input current at 5V 285 mA max a 135 mA standby 2 5 mA RS 232 sleep mode 2 5 mA USB suspend Input Power 1 5W max in the 4 14V rangea Performance Characteristics Light Source Dual LEDs Roll Tilt Tolera...

Page 347: ...ative humidity non condensing Drop Specifications 50 drops from 2 meters 6 5 feet to concrete 30 C to 50 C Ambient Light Immunity Up to 100 000 LUX in sunlight Contaminants Spray rain Dust particulate...

Page 348: ...riptions in Table 46 apply to the connector on the reader and are for ref erence only Table 46 Standard Cable Pinouts Reader Side Pin 1 Pin 10 Cable Clip Latch To Host Cable Cable Strain Relief Bottom...

Page 349: ...338 PowerScanTM PD7100 Corded NOTES...

Page 350: ...referred default settings for these same configurable features Table 47 Standard Defaults Parameter Default Your Setting Page Number General Features Double Read Timeout 0 4 Second 17 Label Gone Timeo...

Page 351: ...CII BEL Disable 54 Beep On Not on File Enable 54 ACK Character ACK 56 NAK Character NAK 58 ACK NAK Timeout Value 600 ms 60 ACK NAK Retry Count 3 Retries 62 ACK NAK Error Handling Ignore Errors Detecte...

Page 352: ...al Speed 66 ms 97 Label Symbology Conversion No Conversion 98 Transmit Noise Disable 99 Data Editing Global Prefix Suffix No Global Prefix Global Suffix 0x0D CR 102 Global AIM ID Disable 104 GS1 128 A...

Page 353: ...able Disable Enable 134 EAN 13 Check Character Transmission Send 134 EAN 13 Flag 1 Character Transmit 135 EAN 13 ISBN Conversion Disable 136 ISSN Enable Disable Disable 136 EAN 13 Minimum Reads 1 137...

Page 354: ...xpanded Enable Disable Disable 159 GS1 DataBar Expanded GS1 128 Emula tion Disable 159 GS1 DataBar Expanded Minimum Reads 1 160 GS1 DataBar Expanded Length Control Variable 161 GS1 DataBar Expanded Se...

Page 355: ...ptions 3 185 Code 32 Check Character Transmission Don t Send 186 Code 32 Start Stop Character Transmis sion Don t Transmit 186 Code 39 CIP French Pharmaceutical Code 39 CIP Enable Disable Disable 187...

Page 356: ...ing Disable 214 Interleaved 2 of 5 CIP HR Interleaved 2 of 5 CIP HR Enable Disable Disable 215 Datalogic 2 of 5 Datalogic 2 of 5 Enable Disable Enable 215 Datalogic 2 of 5 Check Character Calcu lation...

Page 357: ...racter Correlation Disable 243 Codabar Stitching Disable 244 ABC Codabar ABC Codabar Enable Disable Disable 245 ABC Codabar Concatenation Mode Static 245 ABC Codabar Dynamic Concatenation Timeout 200...

Page 358: ...e 271 Standard 2 of 5 Stitching Disable 272 Industrial 2 of 5 Industrial 2 of 5 Enable Disable Disable 273 Industrial 2 of 5 Check Character Calcu lation Disable 273 Industrial 2 of 5 Check Character...

Page 359: ...Set Length 2 50 Chars 292 MSI Minimum Reads 4 Reads 294 MSI Decoding Level Level 3 295 Disable 296 Plessey Plessey Enable Disable Disable 297 Plessey Check Character Calculation Enable Plessey Std and...

Page 360: ...Enable Disable Disable 320 Codablock F AIM Check Enable Check C 320 Codablock F Length Control Variable 321 Codablock F Set Length 1 3 Chars 322 Codablock F Set Length 2 100 Chars 324 Code 4 Code 4 E...

Page 361: ...erface RS232 WN Expand UPC A to EAN 13 Enable UPC E Check Character Transmission Disable Parity Odd Parity Handshaking Control RTS CTS Transmission Label ID Code Prefix GS1 128 AIM ID Disable UPCE Lab...

Page 362: ...te 115200 Baud Transmission Label ID Code Prefix GS1 128 AIM ID Disable UPCA Label ID Character s C UPCE Label ID Character s D EAN 8 Label ID Character s A EAN 13 Label ID Character s B Code ISBN Lab...

Page 363: ...L EAN13 P5 Label ID Character s M EAN13 GS1 128 Label ID Character s GS1 DataBar 14 Omnidirectional Label ID Character s u GS1 DataBar Expanded Label ID Character s t GS1 DataBar Limited Label ID Cha...

Page 364: ...rors on the reader An optional Green Spot also performs useful functions The tables below list these indications One exception to the behaviors listed in the tables is that the reader s functions are...

Page 365: ...continuously While in Stand Mode or Trigger Object Sense mode the green spot shall be on while in stand watch state N A N A Green Spota flashes momen tarily Upon successful read of a label the softwa...

Page 366: ...olation mode If the reader is reset the sequence will be repeated The following table describes the LED flashes beep codes associated with an error found 1 Field Replaceable Unit FRU NUMBER OF LED FLA...

Page 367: ...356 PowerScanTM PD7100 Corded NOTES...

Page 368: ...rcodes in this appendix are typical representations for their symbology types UPC A EAN 13 Code 39 Code 128 Interleaved 2 of 5 0 12345 67890 5 3 456789 012340 123ABC 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7...

Page 369: ...358 PowerScanTM PD7100 Corded Sample Barcodes continued Code 32 Codabar Code 93 Code 11...

Page 370: ...low see GS1 DataBar RSS on page 359 10293847560192837465019283746029478450366523 GS1 DataBar Expanded Stacked 1234890hjio9900mnb GS1 DataBar Expanded 08672345650916 GS1 DataBar Limited 55432198673467...

Page 371: ...360 PowerScanTM PD7100 Corded NOTES...

Page 372: ...Product Reference Guide 361 Appendix E Keypad Use the barcodes in this appendix to enter numbers as you would select digits characters from a keypad 0 1 2 3 4 5...

Page 373: ...362 PowerScanTM PD7100 Corded 6 7 8 9 A B C...

Page 374: ...Product Reference Guide 363 D E F...

Page 375: ...364 PowerScanTM PD7100 Corded NOTES...

Page 376: ...edge and USB Keyboard platforms Control Character 00 Characters from 00 to 0x1F are sent as control character Ctrl Keys special keys are located from 0x80 to 0xA1 Control Character 01 Characters from...

Page 377: ...EOT C D ENQ C S E ACK C S F BEL C S G BS C S H HT TAB LF C S J VT C S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S...

Page 378: ...X6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I...

Page 379: ...A 091 A 092 A 093 A 094 A 095 6x A 096 A 097 A 098 A 099 A 100 A 101 A 102 A 103 A 104 A 105 A 106 A 107 A 108 A 109 A 110 A 111 7x A 112 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A...

Page 380: ...12 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A 123 A 124 A 125 A 126 A 127 8x A 0128 A 0129 A 0130 A 0131 A 0132 A 0133 A 0134 A 0135 A 0136 A 0137 A 0138 A 0139 A 0140 A 0141 A 0142...

Page 381: ...AB LF C S J VT C S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C...

Page 382: ...er is 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Cl Cl BS Tab S Tab Enter Keypd Enter Ins 1x F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M...

Page 383: ...Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C S _ 2x Space 3x 0 1 2 3 4 5 6 7...

Page 384: ...3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E...

Page 385: ...K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C S _ 2x Space 3x 0...

Page 386: ...x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G...

Page 387: ...M PD7100 Corded Microsoft Windows Codepage 1252 Windows 1252 is a character encoding of the Latin alphabet used by default in the leg acy components of Microsoft Windows in English and some other West...

Page 388: ...Microsoft Windows Codepage 1252 Product Reference Guide 377 NOTES...

Page 389: ...378 PowerScanTM PD7100 Corded NOTES...

Page 390: ...Code 39 98 CTS 50 D Decode Capability 336 Defaults 339 Depth of Field 335 Dimensions 335 Drop Specifications 336 E eading trailing noise 99 Electrical Safety 336 EMI RFI 336 Error Codes 355 Errors 355...

Page 391: ...25 26 Read Beeper Volume Good 28 Request to Send 50 Roll Tilt Tolerance 335 RS 232 interface selection 12 RS 232 Serial Connection 6 RTS 50 S sample bar codes code 128 357 code 39 357 interleaved 2 o...

Page 392: ...14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I J K L M N O P Q R S T U V...

Page 393: ...Datalogic Scanning KK Telephone 81 0 3 3491 6761 japan scanning datalogic com Latin America Datalogic Scanning Inc Telephone 305 591 3222 latinamerica scanning datalogic com Singapore Datalogic Scann...

Reviews: