OCR Programming
8-16
PowerScan
®
7000 2D
4.) when the modulo 11 check character “0123456789X” is pro-
grammed.
Please note that all these commands can be combined into a single serial
programming command:
OCRENA2,TMP”ISBNggggggggggggctCdddd hdddEtCdddd
hddddE”,GPG”0123456789-”,GPH”P\”,CHK”0123456789X”.
These commands can be encoded into the following Aztec Code symbol:
OCR Template Codes
†
One or more two-digit numbers and
Save
are required after reading this programming
symbol. Refer to the
Programming Chart on page B-5
of this manual.
NOTE
Reading more than three rows of OCR is not
recommended. Contact the factory if you have
an application that requires reading four or
more rows of OCR.
Enter OCR Template †
Enter User-Defined
Variable “h”†
Enter User-Defined
Variable “g”†
Summary of Contents for POWERSCAN 7000 2D Imager
Page 1: ...PowerScan 7000 2D Imager Product Reference Guide...
Page 8: ...vi PowerScan 7000 2D...
Page 30: ...Terminal Interfaces 2 12 PowerScan 7000 2D NOTES...
Page 118: ...Symbologies 6 50 PowerScan 7000 2D NOTES...
Page 130: ...Imaging Commands 7 12 PowerScan 7000 2D NOTES...
Page 148: ...OCR Programming 8 18 PowerScan 7000 2D NOTES...
Page 154: ...Utilities 9 6 PowerScan 7000 2D NOTES...
Page 182: ...Serial Programming Commands 10 28 PowerScan 7000 2D NOTES...
Page 194: ...A 8 PowerScan 7000 2D NOTES...
Page 198: ...B 4 PowerScan 7000 2D OCR Programming Chart a e d g c h t l Discard Save r...
Page 199: ...Programming Chart Product Reference Guide B 5 Programming Chart A C B F E D 1 0 2 3...
Page 201: ...Programming Chart Product Reference Guide B 7 NOTES...
Page 202: ...B 8 PowerScan 7000 2D NOTES...
Page 203: ......