TECHNICAL FEATURES
Product Reference Guide
157
7.3 System
CONFIGURATION
System Configuration
BC 8030-BT
Max number of devices per base station
4
7.4 Status
Indicators
The scanner has two indicator LEDs and a Beeper. The BC-8000 and C-8000 cradles have four LED indicators (three for
BC-8010 model) and a Beeper. They signal several operating conditions, which are described in the tables below.
H
= high tone
L
= low tone
POWERSCAN™ BT8300 READER START-UP
Beeper
¹
Meaning
L L L L
Parameters loaded correctly
H H H H
long tones
Parameter loading error, reading or writing error in the non volatile memory
H L H L
Hardware error in EEPROM
POWERSCAN™ BT8300 READER CONFIGURATION
Beeper¹ Meaning
H H H H
Correct entry or exit from Configuration mode
L
Good read of a command
L L L
Command read error
POWERSCAN™ BT8300 READER DATA ENTRY
Beeper¹ LED Good
Read
Spot
Meaning
one beep
²
ON
ON
Correct read of a code in normal mode
H L long
TX error between PowerScan™ BT8300 and BC-
8030-BT
H long
ON
ON
Successful advanced format concatenation
H H H
Timeout expired – operation not completed
H H long
Error in advanced data formatting
OFF
OFF
Ready to read a code
¹
Only the Beeper Intensity command can modify these signals.
²
The data entry good read tone is user-configurable with all the Beeper commands in the Reading Parameters section.
For M-series readers, normally this results in two beeps; the first indicates that the reader has decoded the code, the
second indicates whether BC 8030-BT has received the data. See also par. 5.8.2.