5.7.3
Interdigit Control
The interdigit control parameter verifies the interdigit spacing for code families
Code 39 and Codabar.
5.8 ADVANCED FORMATTING
5.8.1
Match Conditions
Selecting an Advanced Formatting and specifying a Match restriction (Code Type,
Code Length, Predefined Characters) the code will be transmitted according to the
order of the defined formats.
For example, defining 2 formats where:
•
Format 1: Match Code type = Code128
•
Format 2: Match Code length = 15 and Match with Predefined Characters
“DATA”
a Code128 “DATA:12345ABCDE” with code length 15 will be formatted following the
Format 1.
To send the same code with the Format 2 it is necessary to invert the format order as
follows:
•
Format 1: Match Code length = 15 and Match with Predefined Characters
“DATA”
•
Format 2: Match Code type = Code128
5.9 RADIO PARAMETERS (M8300 SERIES ONLY)
5.9.1
Radio Protocol Timeout
This parameter sets the valid time to wait before transmission between the M8300
series reader and BC-80X0 cradle is considered failed.
This parameter should be set taking into consideration the radio traffic (number of
readers in the same area).
If the RS-232 interface is used with ACK/NACK enabled, this parameter should be at
least equal to the RX Timeout parameter for low traffic environments. It should be
increased if there are many readers in the same area.
It can be set between 2 and 19 seconds.