background image

Compliance

18

PowerScan® M8300

WEEE COMPLIANCE

English

For information about the disposal of Waste Electrical and Electronic Equipment
(WEEE), please refer to the website at www.scanning.datalogic.com.

Italian

Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche
consultare il sito Web www.scanning.datalogic.com.

French

Pour toute information relative à l’élimination des déchets électroniques (WEEE),
veuillez consulter le site Internet www.scanning.datalogic.com.

German

Informationen zur Entsorgung von Elektro- und Elektronik- Altgeräten (WEEE)
erhalten Sie auf der Webseite www.scanning.datalogic.com.

Spanish

Si desea información acerca de los procedimientos para el desecho de los residuos del
equipo eléctrico y electrónico (WEEE), visite la página Web
www.scanning.datalogic.com.

Portuguese

Para informações sobre a disposição de Sucatagem de Equipamentos Eléctricos e
Eletrônicos (WEEE - Waste Electrical and Electronic Equipment), consultar o site web
www.scanning.datalogic.com.

Chinese

有关处理废弃电气电子设备 (WEEE) 的信息, 请参考

Datalogic

公司的网站:

http://www.scanning.datalogic.com/

Japanese

廃電気電子機器 (WEEE) の処理についての関連事項は

Datalogic

のサイト

www.scanning.datalogic.com

, をご参照下さい。

Waste Electrical and Electronic Equipment (WEEE) Statement

Summary of Contents for PowerScan M8300

Page 1: ...PowerScan M8300 Readers Quick Reference Guide ...

Page 2: ... Datalogic website www scanning datalogic com or provided on appropriate media If you visit our website and would like to make comments or sug gestions about this or other Datalogic publications please let us know via the Con tact Datalogic page Disclaimer Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate however Datalogic reserves the righ...

Page 3: ...es versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet Ce manuel est aussi disponible en version française Cliquez sur www datalogic com D Im Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation von diesem Produkt Die deutschsprachige Version dieses Handbuches ist auch verfügbar Adresse www datalogic com E En Internet están disponibl...

Page 4: ...rScan M8300 laser readers automatically scan barcodes at a distance Simply aim and pull the trigger SCAN LINE POSITION Code scanning is performed along the scan line emitted from the reading window This line must cross the entire code The best reading angles are indicated in the figure below READING ANGLE Successful scanning is obtained by tilting the reader with respect to the barcode to avoid di...

Page 5: ...which should be aimed over the code center to get the best reading performance see figure 1 above By completely pressing the trigger the scan line appears to start the code scanning 2 After setting up the reader you can enable or disable the aiming system by reading the codes below Disable Aiming System Default Ì Bj0 Î Disable Aiming System Default Ì Bj1 Î ...

Page 6: ... battery charger turns green To change the batteries unscrew the retaining screw and extract the battery pack from the reader handle Then insert the new battery pack into the reader handle and tighten the screw See the following figures Figure 1 Changing the Batteries Do not incinerate disassemble short terminals or expose to high tem perature Risk of fire explosion Use specified charger only Risk...

Page 7: ...BC 80X0 cradle to the Host For installation and connection infor mation see the BC 80X0 Quick Reference Manual 2 Charge the PowerScan M8300 battery using an BC 80X0 or the C 8000 charger as described in this Quick Reference manual A full charge takes 4 hours if using an external power supply while it takes up to 10 hours if supplying power through the USB port 3 Configure the reader as described i...

Page 8: ...es To rapidly configure your point to point application END of procedure YOUR READER IS NOW READY TO READ CODES 1 Apply the bind address label onto the BC 80X0 base station as indicated in the BC 80X0 Quick Reference Manual 2 When the BC 80X0 cradle is connected and powered read the Bind Address label to pair the PowerScan M8300 to the BC 80X0 cradle The green LED on the PowerScan M8300 will blink...

Page 9: ...r the numeric code selection of steps 3 4 and 5 use the table at the end of this Quick Reference 1 Restore PowerScan M8300 Default Ì oÎ 2 Enter Configuration Ì Î 3 Set Date ÌIA Î six digits for Day Month and Year DDMMYY 4 Set Time ÌIB Î four digits for Hours and Minutes HHMM 5 Set Radio Address ÌRA0RFHÎ four digits for the PowerScan M8300 Address from 0000 to 1999 All readers used in the same area...

Page 10: ...rs to the same cradle see the following section Using Multiple Readers with Same Cradle Bind Ì RN0 IÎ The green LED on the PowerScan M8300 will blink the reader is ready to be positioned onto the cradle 8 Firmly position the reader onto the cradle within 10 seconds a beep will be emitted signaling that the BC 80X0 cradle has been paired to the PowerScan M8300 and the green LED on the reader will g...

Page 11: ...AN M8300 STAR MODEM STAND ALONE SETUP To configure a PowerScan M8300 reader to communicate with STAR Modem in Stand Alone Mode follow the PowerScan M8300 BC 80X0 Stand Alone Setup procedure substituting steps 6 and 7 with those below END of procedure YOUR READER IS NOW READY TO READ CODES 7 Join Ì RN1 NÎ The green LED on the PowerScan M8300 will blink the reader is ready to be positioned onto the ...

Page 12: ...vices such as Stargate RF base stations 1 Restore PowerScan M8300 Default Ì oÎ 2 Enter Configuration Ì Î 3 Set Date ÌIA Î six digits for Day Month and Year DDMMYY 4 Set Time ÌIB Î four digits for Hours and Minutes HHMM 5 Set the connection according to the length of the codes to be read Code Length 240 Characters ÌRA1aÎ Code Length 240 Characters not for systems with BC 80X0 as Master ÌRA2dÎ ...

Page 13: ...readers used in the same area must have different addresses 7 Set First STAR System Address ÌRSRÎ four digits from the Numeric Table in the range 0000 to 1999 8 Set Last STAR System Address ÌRTTÎ four digits from the Numeric Table in the range 0000 to 1999 Whenever the system is composed of a single base station the first and last base station addresses steps 7 and 8 must have the same value 9 Exi...

Page 14: ...haracters Standard Code 39 no check digit control variable length code 1 99 characters Code 128 variable length code 1 99 characters disabled codes EAN 128 ISBT128 Code 93 Codabar pharmaceutical codes MSI Code 11 Code 16K Code 49 GS1 DataBar GS1 DataBar includes the following symbologies GS1 DataBar Omnidirectional GS1 DataBar Stacked GS1 DataBar Expanded and GS1 DataBar Limited RADIO PARAMETERS r...

Page 15: ...agram Max Resolution 0 076 mm 3 mils 0 19 mm 7 5 mils PCS minimum Datalogic Test Chart 15 25 Scan Angle 42 13 5 0 7 Laser Safety Class 2 EN 60825 1 CDRH Radio Features European Models USA Models Radio Frequency 433 92 MHz 910 MHz Bit rate 19200 baud 36800 baud Range in open air 50 m 30 m System Configuration BC 80X0 STARGATE Max number of devices per base station 32 255 Max number of devices in th...

Page 16: ...4 36 48 60 96 36 24 12 0 12 24 36 cm 72 84 108 cm 0 19 mm 7 5 mils 0 25 mm 10 mils 0 33 mm 13 mils 0 50 mm 20 mils 1 00 mm 40 mils 1 38 mm 55 mils 0 13 mm 5 mils 0 38 mm 15 mils 100 200 300 400 500 800 100 600 700 1 00 mm 40 mils 1 38 mm 55 mils 1 75 mm 70 mils 0 200 300 100 200 300 cm 1000 cm 900 2 50 mm 100 mils ...

Page 17: ... scanning datalogic com and click on the links indicated for further information including PRODUCTS Search through the links to arrive at your product page where you can down load specific Manuals and Software Utilities including Datalogic Aladdin a multi platform utility program that allows device con figuration using a PC It provides RS 232 interface configuration as well as con figuration barco...

Page 18: ... undesired operation FCC ID U4F0015 RADIO COMPLIANCE Contact the competent authority responsible for the management of radio frequency devices of your country to verify any possible restrictions or licenses required Refer to the web site http europa eu int comm enterprise rtte spectr htm for further information LASER SAFETY COMPLIANCE The laser scanner conforms to the applicable requirements of bo...

Page 19: ...ice class label LED CLASS Class 1 LED product This product conforms to EN60825 1 2001 IC INDUSTRY CANADA Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device ITALIANO Classe 2 LUCE LASER NON FISSARE IL RAGGIO APPARECCHIO LASER DI CLASSE 2 D...

Page 20: ...ur Entsorgung von Elektro und Elektronik Altgeräten WEEE erhalten Sie auf der Webseite www scanning datalogic com Spanish Si desea información acerca de los procedimientos para el desecho de los residuos del equipo eléctrico y electrónico WEEE visite la página Web www scanning datalogic com Portuguese Para informações sobre a disposição de Sucatagem de Equipamentos Eléctricos e Eletrônicos WEEE Wa...

Page 21: ...Numeric Table Quick Reference Guide 19 NUMERIC TABLE Ì01Î 0 Ì12Î 1 Ì23Î 2 Ì34Î 3 Ì45Î 4 Ì56Î 5 Ì67Î 6 Ì78Î 7 Ì89Î 8 Ì9 Î 9 ...

Page 22: ...Numeric Table 20 PowerScan M8300 NOTES ...

Page 23: ...t den folgenden Normen entspricht Esta declaración se basa en el cumplimiento de los productos con las siguientes normas Datalogic Scanning Inc 07 959 Terry Street Eugene OR 97402 e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos 1999 5 EEC R TTE ETSI EN 301 489 3 v1 4 1 August 2002 ElectroMagnetic Compatibility and Radio spectrum Matters ERM Elect...

Page 24: ...ne 39 0 39 62903 1 italy scanning datalogic com Japan Datalogic Scanning KK Telephone 81 0 3 3491 6761 japan scanning datalogic com Latin America Datalogic Scanning Inc Telephone 305 591 3222 latinamerica scanning datalogic com Singapore Datalogic Scanning Singapore PTE LTD Telephone 65 6435 1311 singapore scanning datalogic com Spain and Portugal Datalogic Scanning Sarl Sucursal en España Telepho...

Reviews: