Symbologies
200
PowerScan® PBT7100 Cordless
Interleaved 2 of 5 (I 2 of 5) — cont.
I 2 of 5 Set Length 1
This feature specifies one of the barcode lengths for
the minimum label length if in
Mode, or the first fixed length if in
Mode. The length includes the barcode’s check and data characters.
The length can be set from 2 to 50 characters in increments of two.
Follow these instructions to set this feature:
1. Determine the desired character length (from 2 to 50). The length must be an even num-
ber.
2. Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20,
etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT I 2 of 5 LENGTH 1 SETTING.
5. Scan the appropriate two digits from the keypad in
, that represent
the length setting which was determined in the steps above. You will hear a two-beep indi-
cation after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
for some examples of how to set this feature.
Table 25. I 2 of 5 Length 1 Setting Examples
NOTE
If you make a mistake before the last character scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
2 Characters
6 Characters
14 Characters
50 Characters
2
Pad with leading zeroes to yield
two digits
02
06
14
50
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT I 2 of 5 LENGTH 1 SETTING
5
Scan Two Characters From
‘0’ and ‘2’
‘0’ and ‘6’
‘1’ and ‘4’
‘5’ AND ‘0’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for POWERSCAN PBT7100 guide
Page 1: ...PowerScan PBT7100 Cordless Linear Imaging Barcode Reader Product Reference Guide...
Page 10: ...8 PowerScan PD7100 Corded NOTES...
Page 14: ...Introduction 4 PowerScan PBT7100 Cordless NOTES...
Page 56: ...General Features 46 PowerScan PBT7100 Cordless NOTES...
Page 82: ...RS 232 USB Com Interfaces 72 PowerScan PBT7100 Cordless NOTES...
Page 104: ...IBM 46XX Interface 94 PowerScan PBT7100 Cordless NOTES...
Page 281: ...Follett 2 of 5 Product Reference Guide 271 NOTES...
Page 282: ...Symbologies 272 PowerScan PBT7100 Cordless...
Page 328: ...318 PowerScan PBT7100 Cordless NOTES...
Page 332: ...322 PowerScan PBT7100 Cordless NOTES...
Page 334: ...324 PowerScan PBT7100 Cordless 6 7 8 9 A B C...
Page 335: ...Product Reference Guide 325 D E F...
Page 336: ...326 PowerScan PBT7100 Cordless NOTES...
Page 346: ...Product Reference Guide 336 IBM XT Table F 9 Scancode Set When Control Character is 00 or 01...
Page 347: ...Product Reference Guide 337 IBM XT cont Table F 10 Scancode Set When Control Character is 02...