General Features
42
PowerScan
TM
PD7100 Corded
Laser Pointer Control
Specifies the amount of time that the laser pointer is turned on preliminary to scanning.
When the trigger is pressed in Trigger Single Mode, the laser pointer will be activated for
the time period configured by this feature. Immediately following this, the reader will
start scanning.
NOTE
The Laser Pointer is a value-added option which might not
have been included when your reader was ordered.
ENTER/EXIT PROGRAMMING MODE
Laser Pointer Control = 0 msec (No preliminary pointer
— i.e. start scanning immediately after trigger)
Laser Pointer Control = 100 msec
Laser Pointer Control = 200 msec
Laser Pointer Control = 300 msec
Laser Pointer Control = 400 msec
Laser Pointer Control = 500 msec
DEFAULT
Summary of Contents for PowerScan PD7130
Page 11: ...8 PowerScanTM PD7100 Corded...
Page 15: ...Introduction 4 PowerScanTM PD7100 Corded NOTES...
Page 21: ...Getting Started 10 PowerScanTM PD7100 Corded NOTES...
Page 81: ...RS 232 USB Com Interfaces 70 PowerScanTM PD7100 Corded NOTES...
Page 88: ......
Page 99: ...USB OEM Interface 88 PowerScanTM PD7100 Corded NOTES...
Page 111: ...Wand Emulation Interface 100 PowerScanTM PD7100 Corded NOTES...
Page 345: ...Symbologies 334 PowerScanTM PD7100 Corded NOTES...
Page 349: ...338 PowerScanTM PD7100 Corded NOTES...
Page 367: ...356 PowerScanTM PD7100 Corded NOTES...
Page 369: ...358 PowerScanTM PD7100 Corded Sample Barcodes continued Code 32 Codabar Code 93 Code 11...
Page 371: ...360 PowerScanTM PD7100 Corded NOTES...
Page 373: ...362 PowerScanTM PD7100 Corded 6 7 8 9 A B C...
Page 374: ...Product Reference Guide 363 D E F...
Page 375: ...364 PowerScanTM PD7100 Corded NOTES...
Page 388: ...Microsoft Windows Codepage 1252 Product Reference Guide 377 NOTES...