7-6
POWERSCAN D8590 User’s Manual
Data Validation
Data Validation
Data Validation
is used to confirm that a decoded string from the imager has complied
with a particular company, industry, or ISO standard. POWERSCAN D8590 Data Validation
is compliant with Department of Defense Unique Identification and ISO/IEC 15434 (Information
Technology – Transfer Syntax for High-Capacity ADC Media) requirements.
Unique Identification
Unique Identification is a mandatory Department of Defense (DoD) requirement on all
solicitations issued January 1, 2004 or later. This policy mandates the use of Unique Item
Identifiers (UIIs) encoded within Data Matrix symbols on equipment and parts procured by
DoD. The POWERSCAN D8590 complies with Department of Defense Standard Practice
Identification (MIL-STD-130).
Once the imager decodes the Data Matrix symbol, and if Unique Item Identifier (UII), Current
Part Number (CPN), and Lot/Batch Number (LBN) are turned on, the POWERSCAN
D8590 checks the ISO/IEC 15434 syntax with ISO/IEC 15418 (ANSI MH10.8.2 – AI and
DI) and ISO/IEC 21849 (ATA – TEI) semantics to construct the UII, CPN, and LBN.
Unique Identification Features
The following data output options are applicable to Data Matrix ECC 200 symbols only and
have no effect on other symbologies.
UII Enabled
Allows the imager to read only message streams encoded in Data Matrix
ECC 200 symbols, then to construct and output a UII string. The message
streams include validation of Unique Item Identifier (UII), Current Part
Number (CPN), and Lot/Batch Number (LBN) strings. When the imager
decodes a symbol but the symbol data does not compy with UII format, it
will stop capturing images and the green LED will illuminate without
beeping, vibrating, or outputing the string.
UII Enabled with
Pass Through
Allows the imager to read UII messages in Data Matrix ECC 200 symbols
and non-UII messages in any type of symbols. The imager’s behavior is
the same as with UII Enabled.
UII Enabled with
Error Messages
Allows the imager to read UII messages in Data Matrix ECC 200 symbols
and output detailed information such as construction type, data components,
or error messages. The imager’s behavior is the same as with UII
Enabled.
Data Validation
Disabled
Disables both UII and ISO/IEC 15434 data validation.
Summary of Contents for PowerScan PD8590-DPM
Page 1: ...PowerScan PD8590 DPM Imager Industrial Corded Handheld Bar Code Reader User s Manual...
Page 32: ...2 18 POWERSCAN D8590 User s Manual Send Receive NOTES...
Page 42: ...3 10 POWERSCAN D8590 User s Manual Illumination Sequence NOTES...
Page 58: ...4 16 POWERSCAN D8590 User s Manual Other Communications Settings in ESP NOTES...
Page 64: ...5 6 POWERSCAN D8590 User s Manual Region of Interest NOTES...
Page 84: ...6 20 POWERSCAN D8590 User s Manual Symbology Identifier NOTES...
Page 110: ...9 8 POWERSCAN D8590 User s Manual Terminal Dropdown Menu NOTES...
Page 121: ...POWERSCAN D8590 User s Manual A 5 Appendices USB Cable Pinouts 1 828 80 mm...
Page 127: ......