ENTER/EXIT PROGRAMMING MODE
1D SYMBOLOGIES
146
POWERSCAN™ PD/PM96XX
INTERLEAVED 2 OF 5 (I 2 OF 5)
The following options apply to the I 2 of 5 symbology.
I 2 of 5 Enable/Disable
When disabled, the reader will not read I 2 of 5 bar codes.
I 2 of 5 Check Character Calculation
This option enables/disables calculation and verification of an optional I 2 of 5 check
character.
CAUTION: When reading this symbology, the settings for I 2 of 5 Length
Control AND I 2 of 5 Check Character Calculation MUST be enabled to
increase decoding safety.
$CI2EN00
I 2 of 5 = Disable
I 2 of 5 = Enable
$CI2EN01
$CI2CC00
I 2 of 5 Check Character Calculation = Disable
I 2 of 5 Check Character Calculation
= Calculate Std Check (Modulo 10 no AR)
$CI2CC01
$CI2CC02
I 2 of 5 Check Character Calculation
= Calculate German Parcel Check