ENTER/EXIT PROGRAMMING MODE
1D SYMBOLOGIES
192
POWERSCAN™ PD/PM96XX
BC412
The following options apply to the BC412 symbology.
BC412 Enable/Disable
Enables/Disables ability of reader to decode BC412 labels.
BC412 Check Character Calculation
Enable this option to enable/disable calculation and verification of an optional BC412 check
character. When disabled, any check character in the label is treated as a data character.
BC412 Length Control
This feature specifies either variable length decoding or fixed length decoding for the
BC412 symbology.
Variable Length:
For variable-length decoding, a minimum length may be set.
Fixed Length:
For fixed-length decoding, two different lengths may be set.
$CBCEN00
BC412 = Disable
BC412 = Enable
$CBCEN01
$CBCCC00
BC412 Check Character Calculation = Disable
BC412 Check Character Calculation = Calculate
$CBCCC01
$CBCLC00
BC412 Length Control = Variable Length
BC412 Length Control = Fixed Length
$CBCLC01