REFERENCES
294
POWERSCAN™ PD/PM96XX
Scanning Active Time
This setting specifies the amount of time that the reader stays in scan ON state once the
state is entered. The range for this setting is from 1 to 255 seconds in 1-second incre
-
ments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 =
005, 20 = 020, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming
Mode.
4. Scan the bar code: SELECT SCANNING ACTIVE TIME SETTING on
.
5. Scan the appropriate three digits from the keypad in
, that represent
the duration which was determined in the steps above. You will hear a two-beep
indication after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See the table below for examples of how to set this fea
-
ture.
Table 21 Scanning Active Time Setting Examples
NOTE: If you make a mistake before the last character, scan the CANCEL
bar code to abort and not save the entry string. You can then start again at
the beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
1 Second
90 Sec.
(1.5 min.)
180 Sec.
(3 min.)
255 Seconds
(4.25 min.)
2
Pad leading zero(es)
001
090
180
255
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT SCANNING ACTIVE TIME SETTING
5
Scan three characters from
‘0’, ‘0’ and ‘1’ ‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’ ‘2’, ‘5’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE