TECHNICAL SPECIFICATIONS
312
POWERSCAN™ PD/PM96XX
USER INDICATIONS FOR PM96XX (GUN ONLY)
Table 35 User Indications for PM96XX Gun
STATUS
3GL AND GOOD READ
LED
BATTERY LED
BUZZER
Power-up
OFF
OFF
Rising Beeps’
Sequence
USB Enumeration Phase
250 msec
a
ON
↔
250 msec OFF
OFF
OFF
USB Suspend
Depends on Power Cable and spe
-
cific configurations
OFF
OFF
Idle
OFF
OFF
OFF
While Reading
OFF
OFF
OFF
Decode Done
Solid ON
Programmable Duration (1 s
default)
OFF
Single Beep
Reader Disabled (POS)
Communication with host
not established
100 msec ON
↔
900 msec OFF
OFF
OFF
Firmware Upgrade
250 msec ON
↔
250 msec OFF
OFF
OFF
Host Download
250 msec ON
↔
250 msec OFF
OFF
OFF
Paging Answer
5 cycles:
100 msec ON
↔
900 msec OFF
OFF
5 Beeps
(when LED ON)
Enter Service Mode
No Effect
OFF
Beeps' Sequence
Label Programming
No Effect
OFF
Beep
ACK Received on
Transmission
OFF
OFF
Single Program
-
mable Beep
(OFF by default)
ACK NOT Received on
Transmission
OFF
OFF
Wrong Beep
base station in USB
Suspend
Depends on Power Cable and spe
-
cific configurations
OFF
OFF
Configuration Alignment
250 msec ON
↔
250 msec OFF
OFF
OFF
Charge in Progress
through microUSB
b
OFF
Blinking: 1 s ON . 1 s OFF
Green (charge = 50% -
99%)
Amber (charge = 1% -
49%)
Red (charge less than 1%)
Reader is unusable until
1% is reached
OFF
Charge Complete through
microUSB
OFF
Solid Green
It goes OFF when
unplugged
OFF
Charge Fault
OFF
OFF
OFF
Charge in Progress
through base station
OFF
OFF
OFF