ENTER/EXIT PROGRAMMING MODE
1D SYMBOLOGIES
118
POWERSCAN™ PD/PM96XX
EAN-13
The following options apply to the EAN-13 symbology.
EAN-13 Enable/Disable
When disabled, the reader will not read EAN-13 bar codes.
EAN-13 Check Character Transmission
Enable this option to transmit the check character along with EAN-13 bar code data.
$C3BEN00
EAN-13
= Disable
EAN-13 = Enable
$C3BEN01
$C3BCT00
EAN-13 Check Character Transmission = Don’t Send
EAN-13 Check Character Transmission = Send
$C3BCT01