GS1 DATABAR™ EXPANDED
ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
129
GS1 DataBar Expanded Length Control
This feature specifies either variable length decoding or fixed length decoding for the
GS1 DataBar Expanded symbology.
Variable Length:
For variable-length decoding, a minimum length may be set.
Fixed Length:
For fixed-length decoding, two different lengths may be set.
GS1 DataBar Expanded Set Length 1
This feature specifies one of the bar code lengths for "
. Length 1 is the minimum label length if in Variable Length Mode,
or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data
characters only.
The length can be set from 1 to 74 characters. See "
detailed programming instructions.
$CXBLC00
GS1 DataBar Expanded Length Control
= Variable Length
GS1 DataBar Expanded Length Control = Fixed Length
$CXBLC01
Select GS1 DataBar Expanded Set Length 1 Setting
$CXBL1
To configure this feature, scan the ENTER/EXIT PRO
-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu
-
meric characters in
represent
-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 1 = 01 (one character)