ENTER/EXIT PROGRAMMING MODE
1D SYMBOLOGIES
180
POWERSCAN™ PD/PM96XX
Code 11 Check Character Transmission
This feature enables/disables transmission of an optional Code 11 check character.
Code 11 Length Control
This feature specifies either variable length decoding or fixed length decoding for the
Code 11 symbology.
Variable Length:
For variable-length decoding, a minimum length may be set.
Fixed Length:
For fixed-length decoding, two different lengths may be set.
$CC1CT00
Code 11 Check Character Transmission = Don’t Send
Code 11 Check Character Transmission = Send
$CC1CT01
$CC1LC00
Code 11 Length Control = Variable Length
Code 11 Length Control = Fixed Length
$CC1LC01