Code 93 Set Length 1
This feature specifies one of the bar code lengths for "
Code 93 Length Control" on page
. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed
length if in Fixed Length Mode. Length includes the bar code’s check and data charac
-
ters.
The length can be set from 1 to 50 characters. See "
for more
detailed programming instructions.
Code 93 Set Length 2
This feature specifies one of the bar code lengths for "
Code 93 Length Control" on page
. Length 2 is the maximum label length if in Variable Length Mode, or the second
fixed length if in Fixed Length Mode. The length includes the bar code’s check and data
characters.
The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this
length (only one fixed length). See "
for more detailed pro
-
gramming instructions.
Select Code 93 Length 1 Setting
$CC9L1
To configure this feature, scan the ENTER/EXIT PRO
-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu
-
-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 1 = 01 (one character)
Select Code 93 Length 2 Setting
$CC9L2
To configure this feature, scan the ENTER/EXIT PRO
-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu
-
-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 2 = 50 (50 characters)