ENTER/EXIT PROGRAMMING MODE
1D SYMBOLOGIES
186
POWERSCAN™ PD/PM96XX
MSI
The following options apply to the MSI symbology.
MSI Enable/Disable
Enables/Disables ability of reader to decode MSI labels.
MSI Check Character Calculation
Enables/Disables calculation and verification of an optional MSI check character.
$CMSEN00
MSI = Disable
MSI = Enable
$CMSEN01
$CMSCC00
MSI Check Character Calculation = Disable
MSI Check Character Calculation = Calculate Mod 10
$CMSCC01
$CMSCC02
MSI Check Character Calculation
= Calculate Mod 11/10
MSI Check Character Calculation
= Calculate Mod 10/10
$CMSCC03