background image

Quick Reference Guide

i

Table of Contents

END USER SOFTWARE LICENSE AGREEMENT (EULA)  ............... iii
Software Product Policy  ................................................................ vi
Description ....................................................................................... 1

General Features .................................................................... 1

Using the PowerScan™ PM9500-RT .............................................. 2
Installing the Battery Pack  ............................................................ 3

Charging the Batteries  .......................................................... 6

Changing the Batteries ................................................  6

Programming ................................................................................... 8

Using Programming Bar Codes  ............................................ 8
Configure Other Settings ....................................................... 8
Resetting Product Defaults  .................................................. 8
Compatibility with the PowerScan™ 8000 family  ............... 9

Set Date and Time  .......................................................................... 9
Linking the Reader ........................................................................10

Link Datalogic RF Devices to Base............................ 10

Power Off  .......................................................................................10
Reading Parameters .....................................................................11

Good Read Green Spot Duration  ........................................11
Digital Watermark Reading .................................................12

Operating Mode .............................................................................13

Scan Mode  ............................................................................13
Motion Aiming Control  ........................................................15

Pick Mode .......................................................................................15
Multiple Label Reading .................................................................16
Technical Specifications  ...............................................................16
LED and Beeper Indications .........................................................19
Error Codes  ....................................................................................22
Cleaning ..........................................................................................23
Datalogic Limited Factory Warranty ...........................................24
Ergonomic Recommendations  ....................................................26
Support Through the Website  .....................................................27
Hex-Numeric Keypad ....................................................................28

Summary of Contents for PowerScan PM9500-RT

Page 1: ...PowerScan Retail PM9500 RT Industrial Cordless Handheld Area Imager Bar Code Reader Quick Reference Guide...

Page 2: ...ou can acquire printed versions by contacting your Datalogic repre sentative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate medi...

Page 3: ...roduct Defaults 8 Compatibility with the PowerScan 8000 family 9 Set Date and Time 9 Linking the Reader 10 Link Datalogic RF Devices to Base 10 Power Off 10 Reading Parameters 11 Good Read Green Spot...

Page 4: ...ii PowerScan Retail PM9500 RT...

Page 5: ...r information implementation tech niques and trade secrets related to the Software b any other trade secrets marked appropriately or identified as proprietary or confidential and c any information tha...

Page 6: ...on 5 2 End User shall not disclose provide or otherwise make available the Propri etary Information of Datalogic or its third party licensors to any person other than End User s authorized employees o...

Page 7: ...International Sale of Goods shall not apply to this Agreement 10 Termination 10 1Either party may terminate this Agreement or any license granted under this Agreement at any time upon written notice i...

Page 8: ...er state country or territory in which End User resides or in which any of End User s assets are located In the event an action is brought to enforce the terms and conditions of this Agreement the pre...

Page 9: ...onal Operating To read a symbol or capture an image you sim ply aim the reader and pull the trigger Since the PowerScan PM9500 RT is a powerful omni directional reader the orientation of the symbol is...

Page 10: ...er bars or elements mil size should be read closer to the unit Symbologies with larger bars or elements mil size should be read farther from the unit If the entire bar code is within the aiming field...

Page 11: ...ttery using any device except for the scanner When the bat tery is used in devices other than the desig nated product it may damage the battery or reduce its life expectancy If the device causes an ab...

Page 12: ...ed by your Datalogic reseller The use of any other power supplies can damage the device and void your warranty Do not disassemble or modify the battery The battery contains safety and protection devic...

Page 13: ...ng on usage and num ber of charges etc after which they should be removed from service especially in mission critical applications Do not continue to use a battery that is showing excessive loss of ca...

Page 14: ...he cradle battery charger turns red The battery is completely charged when the Reader LED on the cradle battery charger turns green Changing the Batteries Fixed Pack Models 1 Unscrew the bottom of the...

Page 15: ...ncinerate disassemble short ter minals or expose to high temperature Risk of fire explosion Use specified charger only Risk of explosion if the battery is replaced by an incorrect type Dispose of the...

Page 16: ...ce to enter Programming Mode scan the desired parameter settings scan the ENTER EXIT bar code again to accept your changes which exits Program ming Mode and returns the reader to normal operation Conf...

Page 17: ...strings and labels refer to the PRG Set Date and Time 1 Scan the Enter Exit Programming bar code below to set date and time ENTER EXIT PROGRAMMING MODE 2 Scan the Set Date bar code six digits for Year...

Page 18: ...nk the handheld with the base To link the handheld and the base press the trigger to wake up the handheld and mount it on the base If the reader was previously linked to another base you must first sc...

Page 19: ...cquisi tion time and if no code is decoded will switch on again before the next acquisition The illuminator will remain on until the symbol is decoded As you read code symbols adjust the distance at w...

Page 20: ...Reading Parameters 12 PowerScan Retail PM9500 RT Digital Watermark Reading ENTER EXIT PROGRAMMING MODE Disable Enable...

Page 21: ...r is pulled and released scanning is activated until programmable dura tion1 has elapsed or the trigger has been pulled again to transition to another state Double Read Timeout1 pre vents undesired mu...

Page 22: ...can Retail PM9500 RT Operating Mode continued ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode Trigger Pulse Multiple Scan Mode Trigger Hold Multiple Scan Mode Flashing Scan Mode Always...

Page 23: ...ansmission process where bar codes that are not within the configurable distance from the center of the aiming pattern are not acknowl edged or transmitted to the host It is active only in Trigger Sin...

Page 24: ...ICS Dimensions Height 212 mm Length 110 mm Width 74 mm Weight 395 g ELECTRICAL CHARACTERISTICS Battery Type Li Ion battery pack Charge time for full charge from full discharge 4 hours with external po...

Page 25: ...DECODE CAPABILITY 1D BAR CODES GS1 Databar linear codes UPC EAN A E 13 8 UPC EAN with P2 P5 Addons UPC EAN Coupons ISBN Code128 EAN128 ISBT128 Code39 Code39 Full ASCII Code39 CIP Code 32 Codabar Inte...

Page 26: ...to concrete Ambient Light Immu nity 100 000 Lux Contaminants Spray rain Dust particulates IP65 ESD Level 20 KV Beeper Speaker 80 dB 10 cm REGULATORY See Regulatory Addendum RADIO FEATURES Frequency w...

Page 27: ...ators INDICATION DESCRIPTION LED BEEPER Power up Beep The reader is in the process of powering up N A Reader beeps four times at highest fre quency and vol ume upon power up Good Read Beep Alabel has...

Page 28: ...essfully linked to the base N A 3 beeps of ascending fre quency Unlink The reader has unlinked from the base N A 3 beeps of descending frequency ROM Failure There is an error in the reader s software...

Page 29: ...el Pro gramming Mode Accep tance of Par tial Label In cases where multiple labels must be scanned to program one feature this indica tion acknowledges each portion as it is successfully scanned N A Re...

Page 30: ...Field Replaceable Unit isolation mode If the reader is reset the sequence will be repeated Press and release the trigger to hear the FRU indication code The following table describes the LED flashes...

Page 31: ...ce during scanning Use a soft dry cloth to clean the product If the product is very soiled clean it with a soft cloth moistened with a diluted non aggressive cleaning solution or diluted ethyl alcohol...

Page 32: ...end from the date of shipment from Datalogic for the duration published by Datalogic for the product at the time of purchase Warranty period Datalogic warrants repaired hardware devices against defect...

Page 33: ...as but not limited to fire water damage floods other natural disasters vandalism or abusive events that would cause internal and external compo nent damage or destruction of the whole unit consum able...

Page 34: ...in connection with the return shipment Ergonomic Recommendations Reduce or eliminate repetitive motion Maintain a natural position Reduce or eliminate excessive force Keep objects that are used frequ...

Page 35: ...neral Duty Handheld Scanners category link From this page you can select your product model from the drop down list which gives you access to Downloads including Data Sheets Manuals Software Utilities...

Page 36: ...Hex Numeric Keypad 28 PowerScan Retail PM9500 RT Hex Numeric Keypad Use the barcodes that follow to enter numbers or alpha characters as you would select characters from a keypad 0 1 2 3 4...

Page 37: ...Hex Numeric Keypad Quick Reference Guide 29 Hex Numeric Keypad continued 5 6 7 8 9...

Page 38: ...Hex Numeric Keypad 30 PowerScan Retail PM9500 RT Hex Numeric Keypad continued A B C D E F...

Page 39: ...Hex Numeric Keypad Quick Reference Guide 31 NOTES...

Page 40: ...Hex Numeric Keypad 32 PowerScan Retail PM9500 RT NOTES...

Page 41: ...Hex Numeric Keypad Quick Reference Guide 33 NOTES...

Page 42: ...Hex Numeric Keypad 34 PowerScan Retail PM9500 RT NOTES...

Page 43: ......

Page 44: ...Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U Datalogic USA Inc 959 Terry Street Eugene OR 97402 USA Telephone 541 68...

Reviews: