background image

Technical Specifications

12

PowerScan™ PM9501-AR

Technical Specifications

The following tables contain Physical and Performance 
Characteristics, User Environment and Regulatory infor-
mation.

Physical Characteristics

Dimensions

Height: 212 mm
Length: 110 mm
Width: 74 mm

Weight 

PM9501-ARXX: 460 g
PM9501-DARXX: 485 g
PM9501-DKARXX: 485 g

Electrical Characteristics

Battery Type

Li-Ion battery pack

Charge time for 
full charge from 
full discharge

4,5 hours with external power supply adapter

a

a. Charge Times are much lower when battery is within daily typical operating 

condition.

Typical 10 hours with Host power (in this case 
no supply adapter is needed)

a

Operating auton-
omy (continuous 
reading)

40,000 + reads (typical, @25°C)

Cradle consump-
tion and DC input 
supply range

Volt 10-30 VDC; Power < 8 W

b

;

Max 500 mA when in host/bus powered 
mode

b

.

b. Typical input current measured under factory default configuration.

Performance Characteristics

Light Source

LED

Roll (Tilt) Tolerance

± 180° 

Pitch Tolerance

± 80° 

Skew (Yaw) Toler-
ance

± 60°

Field of View

14° x 10.5° up to 1m. Over 3 m: 14.4° x 10.8°

Print Contrast Mini-
mum

15% minimum reflectance

Resolution

Max resolution 1D 3mils
Max resolution 2D 4 mils

Summary of Contents for PowerScan PM9501-AR Series

Page 1: ...PowerScan PM9501 AR Family Industrial Cordless Handheld Auto Range Area Imager Bar Code Reader Quick Reference Guide ...

Page 2: ...d you can acquire printed versions by contacting your Datalogic repre sentative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Data logic publications please let us know via the Contact Data logic page Disclaimer Datalogic has tak...

Page 3: ...ogramming 6 Using Programming Bar Codes 6 Configure Other Settings 6 Resetting Product Defaults 6 Compatibility with the PowerScan 8000 family 7 Set Date and Time 7 Linking the Reader 8 Link Datalogic RF Devices to Base 8 Power Off 8 Operating Mode 9 Scan Mode 9 Pick Mode 11 Multiple Label Reading 11 Technical Specifications 12 LED and Beeper Indications 15 Error Codes 18 Cleaning 19 Datalogic Lim...

Page 4: ...ii PowerScan PM9501 AR NOTES ...

Page 5: ...e shall mean acquire under license End User is not entitled to receipt or use of the source code of any licensed Software 1 4 Portions of the Datalogic Product are protected by the relevant and applicable patent and copyright laws international treaty provisions and other applicable laws Therefore End User must treat the Datalogic Product like any other copy righted material e g a book or musical ...

Page 6: ...t any and all claims actions suits or pro ceedings as well as any and all losses liabilities damages costs and expenses including reasonable attorney s fees arising out of or accruing from or related to Licensee s failure to comply with the terms of this Agreement including but not limited to 1 non compliance with any applicable laws or regulations with Data logic product documentation 2 unauthori...

Page 7: ...tion of the laws of the country in which End User obtained the license to govern interpret and enforce all of End User s and Datalogic s respective rights duties and obligations arising from or relating in any manner to the subject matter of this Agreement without regard to conflict of law principles The United Nations Convention on Contracts for the International Sale of Goods does not apply All ...

Page 8: ... otherwise fails to appoint an arbitrator within 30 days of the date the other party appoints its the first appointed arbitrator will be the sole arbitrator provided that the arbi trator was validly and properly appointed All proceedings will be conducted including all documents presented in such proceedings in the English language The English language version of these terms and conditions prevail...

Page 9: ...l omni directional reader the orientation of the symbol is not important Decoding Thanks to powerful algorithms PowerScan PM9501 AR reliably decodes all major 1D linear barcodes 2D stacked codes such as PDF417 2D matrix symbols such as DataMatrix postal codes such as POSTNET PLANET The data stream acquired from decoding a symbol is rapidly sent to the host The reader is immedi ately available to r...

Page 10: ...ing starts Aiming Pointer Scan the following symbols to enable or disable the aim ing pointer The field of view indicated by the aiming system and the illumination area will be smaller when the reader is closer to the code and larger when it is farther from the code Symbologies with smaller bars or elements mil size should be read closer to the unit Symbologies with larger bars or elements mil siz...

Page 11: ... packs may get hot explode or ignite and cause serious injury if exposed to abusive conditions Be sure to fol low the safety warnings that follow Do not place the battery pack in fire or heat Do not connect the positive terminal and neg ative terminal of the battery pack to each other with any metal object such as wire Do not carry or store the battery pack together with metal objects WARNING Do n...

Page 12: ...19 EU and subsequent modifications US and China regulatory and others laws and regulations about the environment CAUTION Always charge the battery at 32 104 F 0 40 C temperature range Use only the authorized power supplies battery pack chargers and docks supplied by your Data logic reseller The use of any other power supplies can damage the device and void your warranty Do not disassemble or modif...

Page 13: ...reen The battery can also be charged in the spare battery slot BC91xx models only or using the Multi Battery Charger accessory Changing the Batteries 1 Push the button at the bottom of the handle as shown to release the battery 2 Pull down to remove the battery Do not incinerate disassemble short termi nals or expose to high temperature at risk of fire explosion Use specified charger only Risk of ...

Page 14: ...to enter Programming Mode scan the desired parameter settings scan the ENTER EXIT bar code again to accept your changes which exits Program ming Mode and returns the reader to normal operation Configure Other Settings Additional programming bar codes are available in the PRG to allow for customizing programming features If your installation requires different programming than the standard factory ...

Page 15: ... strings and labels refer to the PRG Set Date and Time 1 Scan the Enter Exit Programming bar code below to set date and time ENTER EXIT PROGRAMMING MODE 2 Scan the Set Date bar code six digits for Year Month and Day YYMMDD from the Hex Numeric Keypad on page 27 Set Date 3 Scan Set Time six digits for Hours Minutes and Seconds HHMMSS from the Hex Numeric Keypad on page 27 Set Time 4 Scan the Enter ...

Page 16: ...k the handheld with the base To link the handheld and the base press the trigger to wake up the handheld and mount it on the base If the reader was previously linked to another base you must first scan the Unlink bar code before re linking to the new base Unlink Power Off Scan the bar code below to shut off power to the handheld until the next trigger pull PowerOff ...

Page 17: ...ding a label does not disable scanning Double Read Timeout1 pre vents undesired multiple reads in this mode Trigger Pulse MultipleWhen the trigger is pulled and released scanning is activated until programmable dura tion1 has elapsed or the trigger has been pulled again to transition to another state Double Read Timeout1 pre vents undesired multiple reads while in this mode FlashingThe reader flas...

Page 18: ... Mode 10 PowerScan PM9501 AR Operating Mode continued ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode Trigger Pulse Multiple Scan Mode Trigger Hold Multiple Scan Mode Flashing Scan Mode Always On ...

Page 19: ...Trigger Single mode If the scanner switches to a different Read Mode Pick Mode is automatically disabled Multiple Label Reading The reader offers a number of options for multiple label reading See the PRG or software configuration tool for descriptions of these features and programming labels NOTE This feature is not compatible with Multiple Labels Reading in a Volume See the PRG for more informat...

Page 20: ... a ChargeTimes are much lower when battery is within daily typical operating condition Typical 10 hours with Host power in this case no supply adapter is needed a Operating auton omy continuous reading 40 000 reads typical 25 C Cradle consump tion and DC input supply range Volt 10 30 VDC Power 8 Wb Max 500 mA when in host bus powered modeb b Typical input current measured under factory default con...

Page 21: ... P5 Addons UPC EAN Coupons ISBN Code128 EAN128 ISBT128 Code39 Code39 Full ASCII Code39 CIP Code 32 Codabar Inter leaved 2 of 5 IATA Industrial 2 of 5 Standard 2 of 5 Code11 MSI Plessey Code 93 Follet 2 5 2D Stacked Codes DataMatrix MaxiCode and QR Codes QR Micro QR and Multiple QR codes Aztec Postal codes including Australian Post China Post Japanese Post KIX Post Planet Code Postnet Royal Mail Co...

Page 22: ...ity 100 000 Lux Contaminants Spray rain Dust particulates IP65 ESD Level 20 KV Beeper Speaker 80 dB 10 cm Regulatory See the Regulatory Addendum for details Radio Features Frequency work ing center 433 920 MHz 910 MHz Programmable Speed 19 2 kb s 115 2 kb s 500 kb s default 36 8 kb s 500 kb s default Typical Range in open air 50 m at 500kb s 120 m at 19 2kb s 140 m at 500kb s 240 m at 36 8kB s fre...

Page 23: ...r code labels Table 1 Normal Operating Indicators INDICATION DESCRIPTION LED BEEPER Power up Beep The reader is in the process of powering up N A Reader beeps four times at highest fre quency and vol ume upon power up Good Read Beep Alabel has been successfully scanned by the reader LED behavior is configurablevia the feature Good Read When to Indi cate seethePRGfor information The reader will bee...

Page 24: ...sfully linked to the base N A 3 beeps of ascending fre quency Unlink The reader has unlinked from the base N A 3 beeps of descending frequency ROM Failure There is an error in the reader s software pro gramming Flashes Reader sounds one error beep at highest vol ume Limited Scan ning Label Read Indicates that a host connection is not estab lished N A Reader chirps six times at the highest frequenc...

Page 25: ...bel Pro gramming Mode Accep tance of Par tial Label In cases where multiple labels must be scanned to program one feature this indi cation acknowl edgeseachportion as it is success fully scanned N A Reader sounds one short beep at highest fre quency and current volume Label Pro gramming Mode Accep tance of Pro gramming Configuration option s have been successfully programmed via labels and the rea...

Page 26: ...eld Replaceable Unit isolation mode If the reader is reset the sequence will be repeated Press and release the trigger to hear the FRU indication code The following table describes the LED flashes beep codes associated with an error found Number of LED Flashes Beeps Error Corrective Action 1 Configuration ContactHelpdeskfor assistance 2 Interface PCB 6 Digital PCB 11 Imager ...

Page 27: ...nce during scanning Use a soft dry cloth to clean the product If the product is very soiled clean it with a soft cloth moistened with a diluted non aggressive cleaning solution or diluted ethyl alcohol CAUTION Do not use abrasive or aggressive cleansing agents or abrasive pads to clean scan win dows or plastics Do not spray or pour liquids directly onto the unit ...

Page 28: ...p and materials on the repaired assembly for a 90 day period starting from the date of shipment of the repaired product from Datalogic or until the expiration of the original warranty period whichever is longer Da talogic does not guarantee and it is not responsible for the mainte nance of damage to or loss of configurations data and applications on the repaired units and at its sole discretion ca...

Page 29: ...nd or viii any consumable or equivalent e g cables power supply batteries keypads touch screen triggers etc No Assignment Customer may not assign or otherwise transfer its rights or obliga tions under this warranty except to a purchaser or transferee of prod uct No attempted assignment or transfer in violation of this provision shall be valid or binding upon Datalogic DATALOGIC S LIMITED WARRANTY ...

Page 30: ...ough the Website Datalogic provides several services as well as technical support through its website Log on to www datalogic com For quick access from the home page click on the search icon and type in the name of the product you re look ing for This allows you access to download Data Sheets Manuals Software Utilities and Drawings Hover over the Support Service menu for access to Ser vices and Te...

Page 31: ...Hex Numeric Keypad Quick Reference Guide 23 Hex Numeric Keypad Use the barcodes that follow to enter numbers or alpha characters as you would select characters from a keypad 0 1 2 3 4 ...

Page 32: ...Hex Numeric Keypad 24 PowerScan PM9501 AR Hex Numeric Keypad continued 5 6 7 8 9 ...

Page 33: ...Hex Numeric Keypad Quick Reference Guide 25 Hex Numeric Keypad continued A B C D E F ...

Page 34: ...Hex Numeric Keypad 26 PowerScan PM9501 AR NOTES ...

Page 35: ......

Page 36: ...d Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S and the E U Datalogic USA Inc 959 Terry Street Eugene OR 97402 U S A Telephone 541 683 5700 Fax 541 345 7140 www datalogic com 820112200 Rev A April 2019 ...

Reviews: