TECHNICAL SPECIFICATIONS 

ELECTRICAL FEATURES 

QL300 

QL500 

Supply Voltage 

10 to 30 Vdc 

(see Voltage Drop below) 

Consumption 

210 mA - 70 mA 

Maximum Distributed Current 
Allowed 

see related reading device manual 
for consumption 

4 A 

Inputs 

see relative reader Reference Manual 

Outputs 

see relative reader Reference Manual 

PHYSICAL FEATURES 

Mechanical Dimensions 

129 x 76 x 27 mm 

(5.1 x 3 x 1.1 in.) 

Weight 

312 g. 

(11 oz.) 

309 

(10.9 oz.) 

ENVIRONMENTAL FEATURES 

Operating Temperature 

0° to 50 

C (+32° to 122 °F) 

Storage Temperature 

-20° to 70 

C (-4° to 158 °F)

Humidity max. 

90% non condensing 

Vibration Resistance 

14 mm @ 2 to 10 Hz 

EN 60068-2-6 
2 hours on each axis 

1.5 mm @ 13 to 55 Hz 

2 g @ 70 to 200 Hz 

Shock Resistance 

30 g; 11 ms; 

EN 60068-2-27 

3 shocks on each axis 

Protection Class 

EN 60529 

IP65 

(when IP protection caps or 

IP cables and reading 

device are correctly 

connected)

IP40 

The  features  given  are  typical  at  a  25 

C  ambient  temperature  (if  not  otherwise 

indicated). 

VOLTAGE DROP AND MAX DISTRIBUTED CURRENT CALCULATIONS 

For  correct  network  management,  the  maximum  number  of  readers  which  can 
propagate power through the QLs must be calculated so that max distributed current is 
not  exceeded  and  so  voltage  drop  doesn't  affect  reader  functioning.  This  is  done 
according to the following formula: 

Voltage Drop = 

(Max Reader Current x Number of readers) x 
(Resistance per Meter per wire* x Cable length in Meters) 

* the resistance calculation must include both wires (Vdc and GND).

Example: 

An  ID-

NET™  network  is  composed  of  4  DS2100N  readers.  Three  2-meter  ID-NET™ 

cables  are  used  to  connect  the  readers,  which  have  Cable  Resistance  =  0.058  Ohms 
per meter per wire. The network power is 24 Vdc. 

(0.2083 A x 4 readers) x [(0.058 x 2) x 6 meters] = 0.58 Vdc voltage drop 

24 Vdc - 0.58 = 23.42 Vdc at reader number 4 (worst case) 

Integrate a sufficient number of QL200s to resupply network power. 

SOFTWARE RELEASE VERIFICATION NOTE 

Starting from software release 2.02.01 the QL500 also supports: 

Ethernet IP (explicit messaging)

Modbus TCP

Backup & Restore

When  Ethernet  TCP/IP  is  enabled,  the  QL500  software  release  is  shown  in  the  read-
only  parameter  in  Genius™  Data  Communication  Settings>  CBX Gateway>Line 
Parameters> 

PrgName

. The Scanner Family must have software package 006 or later. 

When Ethernet TCP/IP is enabled, the QL500 software release is shown in t

he VisSet™ 

Welcome menu. The Matrix Family reader must have software release 6.10 or later. 

For more information on these features see the reader's Help On Line.

 

TYPICAL LAYOUTS 

Point to Point - Matrix 21

0™ with QL500 (Ethernet to Host) 

1

The  reader  connected  to  the  QL500  must  be  configured  for  Ethernet  communication.  See  the 
QL500/BM2x0  Ethernet  Configuration  sheet  provided  with  this  device  or  the  Setup  Procedure  Using 
Programming Barcodes available on the CD-ROM. 

ID-

NET™ Synchronized Network - Matrix 410™ Master with QL300 

+ Matrix 41

0™ Slaves with QL150

TRIGGER 

In  order  to  allow  direct  trigger  cabling  between  the  photocell  and  the  QL300/500  using  standard  M12  A-
coded one-to-one cables, the trigger signal has been internally wired to manage PNP type photocells. The 
external trigger therefore 

must be connected as shown in the diagram below

EXTERNAL TRIGGER 

Ground 

Signal 

V

CC

 

READER 

19 

13 

Vdc 

I1B 

QL300/500 

+V 

nc 

19 

13 

T

ri

g

g

er

 

18 

I1A 

I1+ 

18 

GND 

-V 

Power 

Vdc

 

2  3 

GN

D

 

R

ead

er

 

I/O PORT 

ID-

NET™ Synchronized Network - DS4800 Master with QL500 

+ DS4800 Slaves with QL200 and QL100

1

The  reader  connected  to  the  QL500  must  be  configured  for  Ethernet  communication.  See  the 
QL500/BM2x0  Ethernet  Configuration  sheet  provided  with  this  device  or  the  Setup  Procedure  Using 
Programming Barcodes available on the CD-ROM. 

2

The above diagram is an example showing layout connections and is not intended to represent power 
limits,  which  instead,  depend  on  each  specific  application.  See  "Voltage  Drop  and  Max  Distributed 
Current Calculations".

 

ID-

NET™ Multidata Network - DS4800 Master with QL300 

+ DS2100N Scanner Slaves with QL300s

COMPLIANCE 

FCC Compliance 

Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to 
use the equipment. 

This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device 
may not cause harmful interference, and (2) this device must accept any interference received, including interference which 
may cause undesired operation. 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the 
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is 
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not 
installed  and  used  in  accordance  with  the  instruction  manual,  may  cause  harmful  interference  to  radio  communications. 
Operation  of  this  equipment  in  a  residential  area  is  likely  to  cause  harmful  interference  in  which  case  the  user  will  be 
required to correct the interference at his own expense. 

CE Compliance 
Warning: 

This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may 
be required to take adequate measures. 

Power Supply 

This product is intended to be installed by Qualified Personnel only. 

This accessory device is intended to be supplied by a UL Listed or CSA Certified Power Unit with «Class 2» or LPS power 
source. 

Host 

QL500 

1

 

PS 

Power 

I/O 

CAB-PW-EXT 

Matrix 210

™ 

Ethernet 

Host 

QL150 

PS 

Power 

Main Interface 

CBL-1490 

ID-NET 

Terminator 

The  ID-NET  network  must  be  terminated  inserting  an 
ID-NET terminator into the QL300 (Master) and into the 
last QL in the network. 

Slave Nodes 

CBL-1480-xx 

CAB-PW-EXT 

CBL-1480-xx 

CAB-AUX03 

CAB-AUX03 

QL300 

CBL-1496 

ID-NET 

Terminator 

Master 

QL150 

ID-

NET™ 

Host 

QL200 

2

 

PS 

Power 

Ethernet Interface 

CBL-1490 

ID-NET 

Terminator 

The  ID-NET  network  must  be  terminated 
inserting an ID-NET terminator into the last 
QL in the network. 
ID-NET  on  the  QL500  is  internally 
terminated. 

Slave Nodes 

CBL-1480-xx 

CAB-PW-EXT 

CBL-1480-xx 

Power 

QL500 

1

 

Master 

QL100 

ID-

NET™ 

Host 

QL300 

PS 

CBL-1490 

ID-NET 

Terminator 

The  ID-NET  network  must  be  terminated  inserting  an 
ID-NET terminator into the QL300 (Master) and into the 
last QL300 in the network. 

Slave 

CBL-1480-xx 

AUX Port 

CBL-1480-xx 

Power 

QL300 

Master 

QL300 

Power 

Power 

Slave 

PS 

PS 

CBL-1496 

ID-NET 

Terminator 

ID-

NET™ 