Enter/Exit Programming Mode
Product Reference Guide
127
I 2 of 5 Set Length 2
This feature specifies one of the bar code lengths for
I 2 of 5 Length Control
. Length 2 is the maximum label length
if in
Variable Length
Mode, or the second fixed length if in
Fixed Length
Mode. The length includes the bar code’s
check and data characters.
The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
Table 8
provides examples for setting Length 2. See
page 217
for detailed instructions on setting this feature.
Table 8. I 2 of 5 Length 2 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
Ignore This
Length
4 Characters
14 Characters
50 Characters
2
Pad with leading zeroes to
yield two digits
00
04
14
50
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT I 2 OF 5 LENGTH 2 SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’
‘0’ and ‘4’
‘1’ and ‘4’
‘5’ AND ‘0’
6
Scan ENTER/EXIT PROGRAMMING MODE
$CI2L2
Select I 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters
Summary of Contents for QuickScan I QD24 Series
Page 10: ...Contents 8 QuickScan I QD24XX NOTES...
Page 24: ...Setup 14 QuickScan I QD24XX NOTES...
Page 28: ...Enter Exit Programming Mode 18 QuickScan I QD24XX NOTES...
Page 42: ...Enter Exit Programming Mode 32 QuickScan I QD24XX NOTES...
Page 182: ...Enter Exit Programming Mode 172 QuickScan I QD24XX NOTES...
Page 214: ...204 QuickScan I QD24XX NOTES...
Page 246: ...References 236 QuickScan I QD24XX...
Page 270: ...Keypad 260 QuickScan I QD24XX A B C D E F...
Page 280: ...270 QuickScan I QD24XX NOTES...