Enter/Exit Programming Mode
Product Reference Guide
131
Standard 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for
Standard 2 of 5 Length Control
. Length 1 is the minimum
label length if in
Variable Length
Mode, or the first fixed length if in
Fixed Length
Mode. Length includes the bar
code’s check and data characters. The length can be set from 1 to 50 characters.
Table 9
provides some examples for setting Length 1. See
page 217
if you want detailed instructions on setting this
feature.
Table 9. Standard 2 of 5 Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
01 Character
07 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT STANDARD 2 OF 5 LENGTH 1 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘1’
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
5
Scan ENTER/EXIT PROGRAMMING MODE
$CS2L1
Select Standard 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
08 = Length 1 is 8 Characters
Summary of Contents for QuickScan I QD24 Series
Page 10: ...Contents 8 QuickScan I QD24XX NOTES...
Page 24: ...Setup 14 QuickScan I QD24XX NOTES...
Page 28: ...Enter Exit Programming Mode 18 QuickScan I QD24XX NOTES...
Page 42: ...Enter Exit Programming Mode 32 QuickScan I QD24XX NOTES...
Page 182: ...Enter Exit Programming Mode 172 QuickScan I QD24XX NOTES...
Page 214: ...204 QuickScan I QD24XX NOTES...
Page 246: ...References 236 QuickScan I QD24XX...
Page 270: ...Keypad 260 QuickScan I QD24XX A B C D E F...
Page 280: ...270 QuickScan I QD24XX NOTES...