LED and Beeper Indicators
Product Reference Guide
27
Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on following
a good read. The good read LED on time can be set within a range of 0.1 to 25.5 seconds
in 100ms increments.
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds. A setting of 0 means that the good read
LED stays on until the next time the trigger is pulled.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with
leading zeroes to yield three digits. For example: 0 = 000, 5 = 000, 20 = 020, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT GOOD READ LED DURATION SETTING.
5. Scan the appropriate three digits from the keypad in
representing the
duration which was determined in the steps above. You will hear a two-beep indication
after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
for some examples of how to set this feature.
Table 3. Good Read LED Duration Setting Examples
NOTE
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
Good Read LED
stays on until next
trigger pull (00)
200ms
1500ms (1.5 sec.)
2500ms (2.5 sec.)
2
Divide by 10 (and pad with leading
zeroes)
000
002
015
025
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT LABEL GONE TIMEOUT SETTING
5
Scan Three Characters From
‘0’, ‘0’ and ‘0’
‘0’, ‘0’ and ‘2’
‘0’, ‘1’ and ‘5’
‘0’, ‘2’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for QuickScan i
Page 10: ...8 QuickScanTM QD2100 NOTES...
Page 14: ...Introduction 4 QuickScan QD2100 NOTES...
Page 76: ...RS 232 USB Com Interfaces 66 QuickScan QD2100 NOTES...
Page 94: ...USB OEM Interface 84 QuickScan QD2100 NOTES...
Page 106: ...Wand Emulation Interface 96 QuickScan QD2100 NOTES...
Page 130: ...Data Editing 120 QuickScan QD2100 NOTES...
Page 346: ...336 QuickScan QD2100 NOTES...
Page 364: ...354 QuickScan QD2100 NOTES...
Page 366: ...356 QuickScan QD2100 Sample Barcodes continued Code 32 Codabar Code 93 Code 11...
Page 368: ...358 QuickScan QD2100 NOTES...
Page 370: ...360 QuickScan QD2100 6 7 8 9 A B C...
Page 371: ...Product Reference Guide 361 D E F...
Page 372: ...362 QuickScan QD2100 NOTES...