background image

Standard Cable Pinouts

Product Reference Guide

        

                   149

Standard Cable Pinouts

Figure 13

 and 

Table 29

 provide standard pinout information for the scanner’s cable.

Figure 13. Standard Cable Pinouts

Pin 1

Pin 10

Cable Clip (Latch)

To Host

Cable

Cable Strain Relief

Bottom of Scanner

Interface Cable Port

Summary of Contents for QuickScan L QD 2300

Page 1: ...QuickScan L QD 2300 Bar Code Scanner Product Reference Guide...

Page 2: ...otices appear on any reproductions of the documen tation Should future revisions of this manual be published you can acquire printed versions by contacting your Datalogic rep resentative Electronic ve...

Page 3: ...nner 7 Chapter 3 Operation 9 Nomenclature 9 LED and Beeper Indications 10 Scan Mode 11 Scanning 12 Aiming 12 Depth of Field 14 Maintenance 14 Chapter 4 Problem Isolation 15 Problem Isolation 15 Chapte...

Page 4: ...oard Wedge Host Types 57 Keyboard Wedge Country Types Country Codes 58 Ignore Unknown Characters 59 Keystroke Delay 60 Intra Keystroke Delay 60 Alternate Numeric Keypad Emulation 61 Caps Lock On 61 Ca...

Page 5: ...nvert Code 39 to Code 32 113 Code 32 Prefix 114 Set Lengths for Code 39 114 Code 39 Check Digit Verification 116 Transmit Code 39 Check Digit 116 Code 39 Full ASCII Conversion 117 Code 39 Buffering Sc...

Page 6: ...49 Appendix B Standard Defaults 151 Appendix C Programming Reference 157 Datalogic Label ID Identifiers 157 AIM Label ID Identifiers 157 Appendix D Sample Bar Codes 161 UPC EAN 161 UPC A 100 161 EAN 1...

Page 7: ...bes parts of the scanner beeper and LED definitions and how to use the scanner in Trigger Single and Stand modes Chapter 4 Problem Isolation outlines troubleshooting procedures addressing various prob...

Page 8: ...en in RS 232 interface mode Manual Conventions The following conventions are used in this document Italics are used to highlight the following Chapters and sections in this and related documents Dialo...

Page 9: ...r Datalogic products The site offers product support prod uct registration warranty information product manuals product tech notes software updates demos and instructions for returning products for re...

Page 10: ...Introduction 4 QuickScan L NOTES...

Page 11: ...menus to set up proper communi cation of the scanner with the host USB connection to a host The scanner autodetects a USB host and defaults to the HID keyboard interface type Select other USB interfac...

Page 12: ...rly secured 3 Connect the other end of the interface cable to the host See the specific host chapter for information on host connections Figure 1 Connecting the Interface Cable NOTE Specific cables ar...

Page 13: ...power 1 Connect the interface cable to the bottom of the scanner as previously described in the section Installing the Interface Cable 2 Connect the other end of the interface cable to the host refer...

Page 14: ...Getting Started 8 QuickScan L NOTES...

Page 15: ...beeper and LED definitions techniques involved in scanning bar codes general instructions and tips about scanning and decode zone diagrams Nomenclature Nomenclature for physical features on the scanne...

Page 16: ...or format error Low high low beeps Advanced Data Formatting ADF transmit error For information about ADF programming refer to Technical Support High high high low beeps RS 232 receive error Parameter...

Page 17: ...hed before the scanner can operate at the highest power level This power up beep occurs more than once The USB bus may put the scanner in a state where power to the scanner is cycled on and off more t...

Page 18: ...Table 2 Aiming For a typical full sized UPC label the scanner should be held between 1 and 7 from the bar code Ensure that the scan line crosses the entire bar code as shown in Figure 5 Figure 5 Corre...

Page 19: ...r light reflecting directly back into the scanner from the bar code can result in specular reflection which can in turn cause difficulties with decoding Tilt the scanner to avoid the dead zone indicat...

Page 20: ...ipe the window using a lens tissue moistened with ammonia water Do not spray water or other cleaning liquids directly onto the scanner or window If the scan window becomes scratched broken or contamin...

Page 21: ...e was scanned Scan the correct numeric bar codes within range for the parameter programmed Scanner emits low high low beeps The Code 39 buffer was erased or there was an attempt to clear or transmit a...

Page 22: ...able aiming pattern See Figure 5 Scanner decodes bar code but does not transmit the data to the host Scanner is not programmed for the cor rect host type Scan the appropriate host type program ming ba...

Page 23: ...ing options e g ADF UPC E to UPC A Conversion Check the scanner s host type parameters or editing options Trigger Nothing happens when the trigger but ton is pressed No power to the scanner Verify tha...

Page 24: ...Problem Isolation 18 QuickScan L NOTES...

Page 25: ...or mation after the power up beeps sound This is only necessary upon the first power up when connecting to a new host To return all features to their default values reference the topic Return to Facto...

Page 26: ...Feature Defaults NOTE See Appendix B Standard Defaults for a listing of all programmable features General Feature Standard Factory Default Page Number Record Your Setting Beeper Tone Medium 22 Beeper...

Page 27: ...tom default parameters can be configured to set unique default values for all parameters After changing all parameters to the desired de fault values scan the Write to Custom Defaults bar code below t...

Page 28: ...ncy tone scan the Low Frequency Medium Frequency or High Frequency bar code Beeper Volume To select a beeper volume scan the Low Volume Medium Volume or High Volume bar code Low Frequency Medium Frequ...

Page 29: ...the scanner currently is in scan the Toggle Scan Mode to switch from Trigger Single to Stand Mode or from Stand Mode to Trigger Single Mode The standard default setting for this feature is Trigger Sin...

Page 30: ...one of the following durations 1 Hour 5 Hours default Infinite Timeout With this setting there is no timeout thus the scanner will never go into sleep mode or beam shut off but will remain in low powe...

Page 31: ...de fault Laser On Time is 3 0 seconds To set a Laser On Time scan the bar code below Next scan the two numeric bar codes from Appendix E Keypad that correspond to the desired On Time Single digit num...

Page 32: ...ype of a scanned bar code This may be useful when the scanner is decoding more than one code type In addition to any sin gle character prefix already selected the Label ID character is inserted betwee...

Page 33: ...ption Global Prefix Suffix on page 28 2 Scan the appropriate prefix suffix bar code below 3 Scan a four digit number i e four bar codes from Appendix E Keypad that corre sponds to that value 4 To corr...

Page 34: ...corresponding to the posi tion s you wish to specify Data As Is DATA SUFFIX PREFIX DATA PREFIX DATA SUFFIX Scan the Enter bar code to complete the change To set values for the prefix and or suffix See...

Page 35: ...Global Prefix Suffix Product Reference Guide 29 Global Prefix Suffix continued PREFIX DATA PREFIX DATA SUFFIX Enter Data Format Cancel...

Page 36: ...host interface 3 Enter the 4 digit substitution value by scanning each digit in Appendix E Keypad To correct an error or change the selection scan Cancel To enable FN1 substitution for keyboard wedge...

Page 37: ...her devices with an available RS 232 port e g com port If the host is not listed in Table 6 refer to the documentation for the host device to set communication parameters to match the host Throughout...

Page 38: ...y into an appropriate outlet 4 Select the RS 232 host type by scanning the appropriate bar code from RS 232 Host Types on page 36 5 To modify any other parameter options scan the appropriate bar codes...

Page 39: ...aracters listed in Table 7 on page 34 These code ID characters are not programmable and are separate from the Transmit Code ID feature The Transmit Code ID feature should not be enabled for these term...

Page 40: ...sponse Time out 2 Sec 9 9 Sec 2 Sec 9 9 Sec 9 9 Sec 9 9 Sec 9 9 Sec Stop Bit Select One One One One One One One ASCII Format 8 Bit 8 Bit 8 Bit 8 Bit 8 Bit 7 Bit 8 Bit Beep On BEL Disable Disable Disab...

Page 41: ...93 None None L L L len None D 2 of 5 H len None H H H len H len UCC EAN 128 L len None P P P len L len MSI None None O O O len None Bookland EAN F F A A A F Trioptic None None None None None None Code...

Page 42: ...ost Types To select an RS 232 host interface scan one of the following bar codes Standard RS 232 ICL RS 232 RS 232 Wincor Nixdorf Mode A RS 232 Wincor Nixdorf Mode B RS 232 Olivetti ORS4500 RS 232 Omr...

Page 43: ...data transmitted per second Set the scanner s baud rate to match the baud rate setting of the host device Otherwise data may not reach the host device or may reach it in distorted form Baud Rate 600...

Page 44: ...0 or 1 based on data to ensure that an odd number of 1 bits are contained in the coded character Select Even parity and the parity bit value is set to 0 or 1 based on data to ensure that an even numb...

Page 45: ...device for the next character in the serial data stream The number of stop bits selected one or two depends on the number the receiv ing terminal is programmed to accommodate Set the number of stop bi...

Page 46: ...whether or not the parity framing and overrun of received characters are checked The parity value of received characters is verified against the parity parameter selected above Check For Received Erro...

Page 47: ...10 msec after sending the last character The host should respond by negating CTS The scanner checks for a de asserted CTS upon the next transmission of data During the transmission of data the CTS lin...

Page 48: ...on regardless of the state of CTS The scanner waits up to Host Serial Response Time out for CTS to be asserted If CTS is not asserted during this time the scanner issues an error indication and discar...

Page 49: ...are no retries when a time out occurs ENQ When this option is selected the scanner waits for an ENQ character from the host before transmitting data If an ENQ is not received within the Host Serial Re...

Page 50: ...RS 232 44 QuickScan L Software Handshaking cont None ACK NAK ENQ ACK NAK with ENQ XON XOFF...

Page 51: ...uide 45 Host Serial Response Time out This parameter specifies how long the scanner waits for an ACK NAK ENQ XON or CTS before determining that a transmission error occurred Minimum 2 Sec Low 2 5 Sec...

Page 52: ...RTS or High RTS line state Beep on BEL When this parameter is enabled the scanner issues a beep when a BEL character is de tected on the RS 232 serial line BEL is issued to gain a user s attention to...

Page 53: ...eters Product Reference Guide 47 Intercharacter Delay This parameter specifies the intercharacter delay inserted between character transmis sions Minimum 0 msec Low 25 msec Medium 50 msec High 75 msec...

Page 54: ...own Characters is selected all bar code data is sent except for unknown char acters and no error beeps sound on the scanner When Do Not Send Bar Codes With Unknown Characters is selected bar code data...

Page 55: ...racter Set for RS 232 ASCII Value Full ASCII Code 39 Encode Character ASCII Character 1000 U NUL 1001 A SOH 1002 B STX 1003 C ETX 1004 D EOT 1005 E ENQ 1006 F ACK 1007 G BELL 1008 H BCKSPC 1009 I HORI...

Page 56: ...33 A 1034 B 1035 C 1036 D 1037 E 1038 F 1039 G 1040 H 1041 I 1042 J 1043 K 1044 L 1045 1046 1047 O 1048 0 0 1049 1 1 1050 2 2 1051 3 3 1052 4 4 1053 5 5 1054 6 6 1057 7 7 1056 8 8 Table 8 ASCII Charac...

Page 57: ...V 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P 1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V...

Page 58: ...96 W 1097 A a 1098 B b 1099 C c 1100 D d 1101 E e 1102 F f 1103 G g 1104 H h 1105 I i 1106 J j 1107 K k 1108 L l 1109 M m 1110 N n 1111 O o 1112 P p 1113 Q q 1114 R r 1115 S s 1116 T t Table 8 ASCII C...

Page 59: ...Reference Guide 53 1117 U u 1118 V v 1119 W w 1120 X x 1121 Y y 1122 Z z 1123 P 1124 Q 1125 R 1126 S 1127 Undefined 7013 ENTER Table 8 ASCII Character Set for RS 232 Continued ASCII Value Full ASCII C...

Page 60: ...RS 232 54 QuickScan L NOTES...

Page 61: ...uter accepts the keystrokes as if they originated from the keyboard This mode adds bar code reading functionality to a system designed for manual keyboard input Keyboard keystrokes are simply passed t...

Page 62: ...age 57 9 To modify any other parameter options scan the appropriate bar codes in this chapter Keyboard Wedge Parameter Defaults Table 9 lists the defaults for Keyboard Wedge host parameters To change...

Page 63: ...de Disable 62 Convert Wedge Data No Convert 62 Function Key Mapping Disable 63 FN1 Substitution Disable 63 Send and Make Break Send 63 1User selection is required to configure this interface and this...

Page 64: ...es Scan the bar code corresponding to the keyboard type If the keyboard type is not listed see Alternate Numeric Keypad Emulation on page 61 North American German Windows French Windows French Canadia...

Page 65: ...cept for unknown char acters and no error beeps sound on the scanner When Do Not Send Bar Codes With Unknown Characters is selected bar code data is sent up to the first unknown character then the sca...

Page 66: ...he delay when hosts require a slower transmission of data Intra Keystroke Delay When enabled an additional delay is inserted between each emulated key depression and release This sets the Keystroke De...

Page 67: ...ry Types Country Codes on page 58 in a Microsoft operating system environment Caps Lock On When enabled the scanner emulates keystrokes as if the Caps Lock key is always pressed Note that if both Caps...

Page 68: ...ode is sent as an A no matter what the state of the keyboard s Caps Lock key Convert Wedge Data When enabled the scanner will convert all bar code data to the selected case NOTE If both Caps Lock On a...

Page 69: ...ot have a bold entry remain the same whether or not this parameter is enabled FN1 Substitution When enabled the scanner replaces FN1 characters in an EAN128 bar code with a key stroke chosen by the us...

Page 70: ...014 NOTE Code 39 Full ASCII interprets the bar code special character preced ing a Code 39 character and assigns an ASCII character value to the pair For example when Code 39 Full ASCII is enabled and...

Page 71: ...CTRL P 1017 Q CTRL Q 1018 R CTRL R 1019 S CTRL S 1020 T CTRL T 1021 U CTRL U 1022 V CTRL V 1023 W CTRL W 1024 X CTRL X 1025 Y CTRL Y 1026 Z CTRL Z 1027 A CTRL ESC1 1028 B CTRL 1029 C CTRL 1030 D CTRL...

Page 72: ...1048 0 0 1049 1 1 1050 2 2 1051 3 3 1052 4 4 1053 5 5 1054 6 6 1055 7 7 1056 8 8 1057 9 9 1058 Z 1059 F 1060 G Table 10 Keyboard Wedge ASCII Character Set Continued ASCII Value Full ASCII Code 39 Enc...

Page 73: ...3 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P 1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X Table 10 Keyboard Wedge ASCII Character Set Continued ASCII...

Page 74: ...1103 G g 1104 H h 1105 I i 1106 J j 1107 K k 1108 L l 1109 M m 1110 N n 1111 O o 1112 P p 1113 Q q 1114 R r 1115 S s 1116 T t Table 10 Keyboard Wedge ASCII Character Set Continued ASCII Value Full AS...

Page 75: ...oke 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M 2078 ALT N 2079 ALT O 2080 ALT P Table 10 Keyboard We...

Page 76: ...12 Keyboard Wedge GIU Key Character Set GUI Keys Keystrokes 3000 Right Control Key 3048 GUI 0 3049 GUI 1 3050 GUI 2 3051 GUI 3 3052 GUI 4 3053 GUI 5 3054 GUI 6 3055 GUI 7 3056 GUI 8 3057 GUI 9 3065 GU...

Page 77: ...GUI O 3080 GUI P 3081 GUI Q 3082 GUI R 3083 GUI S 3084 GUI T 3085 GUI U 3086 GUI V 3087 GUI W 3088 GUI X 3089 GUI Y 3090 GUI Z Table 13 Keyboard Wedge F Key Character Set F Keys Keystroke 5001 F1 500...

Page 78: ...5017 F17 5018 F18 5019 F19 5020 F20 5021 F21 5022 F22 5023 F23 5024 F24 Table 14 Keyboard Wedge Numeric Keypad Character Set Numeric Keypad Keystroke 6042 6043 6044 undefined 6045 6046 6047 6048 0 604...

Page 79: ...Character Set Extended Keypad Keystroke 7001 Break 7002 Delete 7003 Pg Up 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 70...

Page 80: ...Keyboard Wedge Interface 74 QuickScan L NOTES...

Page 81: ...ional power supply is required Throughout the programming bar code menus default values are indicated with asterisks Connecting a USB Interface Figure 12 USB Connection The scanner connects with USB c...

Page 82: ...ar code from USB Device Type on page 77 4 On first installation when using Windows the software prompts to select or install the Human Interface Device driver To install this driver provided by Window...

Page 83: ...ypes Country Codes North American 78 USB Keystroke Delay No Delay 80 USB CAPS Lock Override Disable 80 USB Ignore Unknown Characters Send 81 Emulate Keypad Disable 81 USB FN1 Substitution Disable 82 F...

Page 84: ...USB HID Keyboard Emulation device USB OEM Handheld NOTE For USB OPOS operation use host type OEM USB and an appropriate driver supplied by Datalogic NOTE When changing USB country keyboard types the...

Page 85: ...uct Reference Guide 79 USB Country Keyboard Types Country Codes continued French Canadian Windows 2000 XP Spanish Windows Italian Windows Swedish Windows UK English Windows Japanese Windows ASCII Port...

Page 86: ...on of data USB CAPS Lock Override This option applies only to the HID Keyboard Emulation device When enabled the case of the data is preserved regardless of the state of the caps lock key This setting...

Page 87: ...cept for unknown characters and no error beeps sound When Do Not Send Bar Codes With Unknown Characters is selected bar code data is sent up to the first unknown character then the scanner issues an e...

Page 88: ...tion Values on page 30 to set the Key Category and Key Value Function Key Mapping ASCII values under 32 are normally sent as a control key sequences see Table 17 on page 84 When this parameter is enab...

Page 89: ...as if the Caps Lock state is enabled on the keyboard This inversion is done regard less of the current state of the keyboard s Caps Lock state Convert Case When enabled the scanner will convert all b...

Page 90: ...E 1006 F CTRL F 1007 G CTRL G 1008 H CTRL H BACKSPACE1 1009 I CTRL I HORIZONTAL TAB1 1010 J CTRL J 1011 K CTRL K 1012 L CTRL L 1013 M CTRL M ENTER1 1014 N CTRL N 1015 O CTRL O 1016 P CTRL P 1017 Q CT...

Page 91: ...B 1035 C 1036 D 1037 E 1038 F 1039 G 1040 H 1041 I 1042 J 1043 K 1044 L 1045 1046 1047 O 1048 0 0 1049 1 1 1050 2 2 1051 3 3 1052 4 4 1053 5 5 Table 17 ASCII Character Set for USB Continued ASCII Valu...

Page 92: ...8 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P 1081 Q Q Table 17 ASCII Character Set for USB Continued ASCII Value Full ASCII Code 39...

Page 93: ...94 N 1095 O _ 1096 W 1097 A a 1098 B b 1099 C c 1100 D d 1101 E e 1102 F f 1103 G g 1104 H h 1105 I i 1106 J j 1107 K k 1108 L l 1109 M m Table 17 ASCII Character Set for USB Continued ASCII Value Ful...

Page 94: ...5 R 1126 S Table 18 USB ALT Key Character Set ALT Keys Keystroke 2064 ALT 2 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F Table 17 ASCII Character Set for USB Continued ASCII Value...

Page 95: ...ALT W 2088 ALT X 2089 ALT Y 2090 ALT Z Table 19 USB GUI Key Character Set GUI Key Keystroke 3000 Right Control Key 3048 GUI 0 3049 GUI 1 3050 GUI 2 3051 GUI 3 3052 GUI 4 Note GUI Shift Keys The Apple...

Page 96: ...UI K 3076 GUI L 3077 GUI M 3078 GUI N 3079 GUI O 3080 GUI P 3081 GUI Q 3082 GUI R 3083 GUI S 3084 GUI T 3085 GUI U 3086 GUI V 3087 GUI W Table 19 USB GUI Key Character Set Continued GUI Key Keystroke...

Page 97: ...F7 5008 F8 5009 F9 5010 F10 5011 F11 5012 F12 5013 F13 5014 F14 5015 F15 5016 F16 5017 F17 5018 F18 5019 F19 5020 F20 5021 F21 Table 19 USB GUI Key Character Set Continued GUI Key Keystroke Note GUI...

Page 98: ...ke 6042 6043 6044 undefined 6045 6046 6047 6048 0 6049 1 6050 2 6051 3 6052 4 6053 5 6054 6 6055 7 6056 8 6057 9 6058 Enter 6059 Num Lock Table 22 USB Extended Keypad Character Set Extended Keypad Key...

Page 99: ...006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 7014 Escape 7015 Up Arrow 7016 Down Arrow 7017 Left Arrow 7018 Right Arrow Table 22 USB Extended K...

Page 100: ...USB Interface 94 QuickScan L NOTES...

Page 101: ...s sound This is only necessary upon the first power up when connected to a new host To return all features to default values scan the appropriate default bar code on page 21 Throughout the programming...

Page 102: ...ble 99 UPC E Enable 99 UPC E1 Disable 100 EAN 8 JAN 8 Enable 101 EAN 13 JAN 13 Enable 101 Bookland EAN Disable 101 Decode UPC EAN JAN Supplementals 2 and 5 digits Ignore 103 Decode UPC EAN JAN Supplem...

Page 103: ...39 Full ASCII Conversion Disable 117 Buffer Code 39 Disable 118 Code 93 Code 93 Disable 120 Set Length s for Code 93 4 to 55 122 Code 11 Code 11 Disable 122 Set Lengths for Code 11 4 to 55 124 Code 11...

Page 104: ...Disable 136 Set Length s for MSI 2 to 55 138 MSI Check Digits One 138 Transmit MSI Check Digit Disable 139 MSI Check Digit Algorithm Mod 10 Mod 10 139 GS1 DataBar RSS DataBar Omnidirectional RSS 14 D...

Page 105: ...UPC EAN Product Reference Guide 99 UPC EAN Enable Disable UPC A UPC E To enable or disable UPC A or UPC E scan the appropriate bar code below Enable UPC A Disable UPC A Enable UPC E Disable UPC E...

Page 106: ...ckScan L Enable Disable UPC E1 UPC E1 is disabled by default To enable or disable UPC E1 scan the appropriate bar code below NOTE UPC E1 is not a UCC Uniform Code Council approved symbology Enable UPC...

Page 107: ...enable or disable EAN 13 or EAN 8 scan the appropriate bar code below Enable Disable Bookland EAN To enable or disable Bookland EAN scan the appropriate bar code below Enable EAN 13 Disable EAN 13 En...

Page 108: ...Enable 378 379 Supplemental Mode to delay only EAN 13 JAN 13 bar codes starting with a 378 or 379 prefix by the supplemental search process All other UPC EAN JAN bar codes are exempted from the search...

Page 109: ...ode UPC EAN JAN Supplementals continued Decode UPC EAN JAN Only With Supplementals Ignore Supplementals Autodiscriminate UPC EAN JAN Supplementals Enable 378 379 Supplemental Mode Enable 978 Supplemen...

Page 110: ...n Scan the bar code below to set a decode redundancy value Next scan two numeric bar codes in Appendix E Keypad Single digit numbers must have a leading zero To correct an error or change a selection...

Page 111: ...always verified to guarantee the integrity of the data Transmit UPC E1 Check Digit The check digit is the last character of the bar code used to verify the integrity of the data Scan the appropriate b...

Page 112: ...tions are given for transmitting UPC A preamble to the host de vice transmit System Character only transmit System Character and Country Code 0 for USA and no preamble transmitted Scan a bar code belo...

Page 113: ...ee options are given for transmitting UPC E preamble to the host de vice transmit System Character only transmit System Character and Country Code 0 for USA and no preamble transmitted Scan a bar code...

Page 114: ...ptions are given for transmitting UPC E1 preamble to the host device transmit System Character only transmit System Character and Country Code 0 for USA and no preamble transmitted Scan a bar code bel...

Page 115: ...data is transmitted as UPC E data without conversion Convert UPC E1 to UPC A Enable this to convert UPC E1 decoded data to UPC A format before transmission Af ter conversion the data follows UPC A fo...

Page 116: ...abled this parameter decodes UPCA bar codes starting with digit 5 EAN 13 bar codes starting with digit 99 and UPCA EAN 128 Coupon Codes UPCA EAN 13 and EAN 128 must be enabled to scan all types of Cou...

Page 117: ...Disable Code 128 To enable or disable Code 128 scan the appropriate bar code below Enable Disable UCC EAN 128 To enable or disable UCC EAN 128 scan the appropriate bar code below Enable Code 128 Disa...

Page 118: ...ank industry Scan the appropriate bar code below to enable or disable ISBT 128 If necessary the host must perform con catenation of the ISBT data Code 39 Enable Disable Code 39 To enable or disable Co...

Page 119: ...priate bar code below Convert Code 39 to Code 32 Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry Scan the appropriate bar code below to enable or disable converting Code 39...

Page 120: ...Code 39 bar codes with 14 characters scan Code 39 One Discrete Length then scan 1 followed by 4 To correct an error or change the selection scan the CANCEL bar code located in Appendix E Keypad Two Di...

Page 121: ...between 4 and 12 characters first scan Code 39 Length Within Range Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero To correct an error or change the selection sca...

Page 122: ...a modulo 43 check digit are decoded Enable this feature if the Code 39 bar codes contain a Modulo 43 check digit Transmit Code 39 Check Digit Scan the appropriate bar code below to transmit Code 39 da...

Page 123: ...w NOTE Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously Code 39 Full ASCII to Full ASCII Correlation is host dependent and is described in the ASCII Character Set table for the...

Page 124: ...feature affects Code 39 only If selecting Buffer Code 39 we recommend configur ing the scanner to decode Code 39 symbology only While there is data in the transmission buffer selecting Do Not Buffer...

Page 125: ...op character The scanner transmits and clears the buffer The scanner issues a low high beep 2 Scan a Code 39 bar code with a leading character other than a space The scanner appends new decode data to...

Page 126: ...ee long high beeps No transmission occurs The data in the buffer is not affected Attempt to Transmit an Empty Buffer If the bar code just read was the Transmit Buffer bar code and the Code 39 buffer i...

Page 127: ...des contain ing either of two selected lengths Select lengths using the numeric bar codes in Appen dix E Keypad For example to decode only those Code 93 bar codes containing either 2 or 14 characters...

Page 128: ...gths for Code 93 continued Code 11 To enable or disable Code 11 scan the appropriate bar code below Code 93 One Discrete Length Code 93 Two Discrete Lengths Code 93 Length Within Range Code 93 Any Len...

Page 129: ...codes contain ing either of two selected lengths Select lengths using the numeric bar codes in Appen dix E Keypad For example to decode only those Code 11 bar codes containing either 2 or 14 characte...

Page 130: ...Symbologies 124 QuickScan L Set Lengths for Code 11 continued Code 11 One Discrete Length Code 11 Two Discrete Lengths Code 11 Length Within Range Code 11 Any Length...

Page 131: ...ies with the specified check digit algorithm This selects the check digit mechanism for the decoded Code 11 bar code The options are to check for one check digit check for two check digits or disable...

Page 132: ...eaved 2 of 5 To enable or disable Interleaved 2 of 5 scan the appropriate bar code below and select an Interleaved 2 of 5 length from the following pages NOTE Code 11 Check Digit Verification must be...

Page 133: ...de only those I 2 of 5 bar codes containing either 2 or 14 characters select I 2 of 5 Two Discrete Lengths then scan 0 2 1 and then 4 To correct an error or to change the selection scan the CANCEL bar...

Page 134: ...bologies 128 QuickScan L Set Lengths for Interleaved 2 of 5 continued I 2 of 5 One Discrete Length I 2 of 5 Two Discrete Lengths I 2 of 5 Length Within Range Default range is 2 to 55 I 2 of 5 Any Leng...

Page 135: ...data complies with either the specified Uniform Symbology Specification USS or the Optical Product Code Council OPCC check digit algorithm Transmit I 2 of 5 Check Digit Scan the appropriate bar code...

Page 136: ...ccomplish this the I 2 of 5 code must be enabled and the code must have a leading zero and a valid EAN 13 check digit Discrete 2 of 5 DTF Enable Disable Discrete 2 of 5 To enable or disable Discrete 2...

Page 137: ...f 5 bar codes containing either 2 or 14 characters select D 2 of 5 Two Discrete Lengths then scan 0 2 1 and then 4 To correct an error or to change the selection scan the CANCEL bar code located in Ap...

Page 138: ...Chinese 2 of 5 Enable Disable Chinese 2 of 5 To enable or disable Chinese 2 of 5 scan the appropriate bar code below D 2 of 5 One Discrete Length D 2 of 5 Two Discrete Lengths D 2 of 5 Length Within R...

Page 139: ...ct this option to decode only Codabar bar codes contain ing either of two selected lengths Select lengths using the numeric bar codes in Appen dix E Keypad For example to decode only Codabar bar codes...

Page 140: ...Symbologies 134 QuickScan L Set Lengths for Codabar continued Codabar One Discrete Length Codabar Two Discrete Lengths Codabar Length Within Range Codabar Any Length...

Page 141: ...tart and stop characters and inserts a space after the first fifth and tenth characters of a 14 character Codabar bar code Enable this fea ture if your host system requires this data format NOTE Bar C...

Page 142: ...he start and stop characters from a decoded Coda bar bar code Enable this feature if your host system requires this data format MSI Enable Disable MSI To enable or disable MSI scan the appropriate bar...

Page 143: ...containing either 2 or 14 charac ters select MSI Two Discrete Lengths then scan 0 2 1 and then 4 To correct an error or to change the selection scan the CANCEL bar code located in Appendix E Keypad Le...

Page 144: ...heck digit is optional If the MSI codes include two check digits scan the Two MSI Check Digits bar code to enable verification of the second check digit See MSI Check Digit Algorithm on page 139 for t...

Page 145: ...without the check dig it MSI Check Digit Algorithm Two algorithms are possible for the verification of the second MSI check digit Select the bar code below corresponding to the algorithm used to enco...

Page 146: ...riate bar code below to enable or disable each variant of DataBar NOTE The GS1 DataBar symbology family was formerly known as RSS Equivalents for each variant in the family are RSS 14 DataBar Omnidire...

Page 147: ...ed bar codes encoding a single zero as the first digit and report the bar code as EAN 13 For bar codes beginning with two or more zeros but not six zeros this parameter strips the leading 0100 and rep...

Page 148: ...2 The following code types must be successfully read twice before being decoded Redundancy Level 3 Code types other than the following must be successfully read twice before being decod ed The follow...

Page 149: ...ide 143 Redundancy Level 4 The following code types must be successfully read three times before being decoded Table 27 Redundancy Level 4 Code Types Code Type Code Length All All Redundancy Level 1 R...

Page 150: ...ing sufficient security in decoding most in spec bar codes Security Level 1 Select this option if misdecodes occur This security level should elimi nate most misdecodes Security Level 2 Select this op...

Page 151: ...ndancy Enable Bi directional Redundancy to add security to linear code type security levels When enabled a bar code must be successfully scanned in both directions forward and reverse before reporting...

Page 152: ...marily quite small Due to various bar code printing technologies this gap may grow larger than the maximum size allowed causing the scanner to be unable to decode the bar code If this problem is encou...

Page 153: ...lor Black or White Performance Characteristics Light Source Laser 650nm laser diode Scan Rate 100 scans per second Scan Width 47 Roll Tilt Tolerance 30 from normal Pitch Tolerance 65 Skew Yaw Toleranc...

Page 154: ...eper Volume User selectable three levels Beeper Tone User selectable three tones Electrostatic Discharge Conforms to 20 kV air direct discharge and 8 kV of contact discharge Regulatory Electrical Safe...

Page 155: ...149 Standard Cable Pinouts Figure 13 and Table 29 provide standard pinout information for the scanner s cable Figure 13 Standard Cable Pinouts Pin 1 Pin 10 Cable Clip Latch To Host Cable Cable Strain...

Page 156: ...the scanner and are for reference only Table 29 Standard Cable Pinouts Pin RS 232 Keyboard Wedge USB 1 RTS nc Jump to Pin 5 2 nc Clk In D 3 nc Data In D 4 Ground Ground Ground 5 RXD nc Jump to Pin 1...

Page 157: ...tures Set Default Parameter Restore Defaults 21 Beeper Tone Medium 22 Beeper Volume High 22 Power Mode Continuous On 23 Scan Line Width Full Width 25 Laser On Time 3 0 Sec 25 Beep After Good Read Enab...

Page 158: ...Data Bits ASCII Format 8 Bit 39 Check Receive Errors Enable 40 Hardware Handshaking None 41 Software Handshaking None 43 Host Serial Response Time out 2 Sec 45 RTS Line State Low RTS 46 Beep on BEL Di...

Page 159: ...pplementals 2 and 5 digits Ignore 102 Decode UPC EAN JAN Supplemental Redundancy 7 104 Transmit UPC A Check Digit Enable 104 Transmit UPC E Check Digit Enable 105 Transmit UPC E1 Check Digit Enable 10...

Page 160: ...able 120 Set Length s for Code 93 4 to 55 121 Code 11 Code 11 Disable 122 Set Lengths for Code 11 4 to 55 123 Code 11 Check Digit Verification Disable 125 Transmit Code 11 Check Digit s Disable 126 In...

Page 161: ...smit MSI Check Digit Disable 139 MSI Check Digit Algorithm Mod 10 Mod 10 139 GS1 DataBar RSS DataBar Omnidirectional RSS 14 Disable 140 DataBar Limited Disable 140 DataBar Expanded Disable 140 Convert...

Page 162: ...156 QuickScan L NOTES...

Page 163: ...ag Character ASCII 93 c Code Character see Table 32 m Modifier Character see Table 33 Table 31 Symbology Characters Code Character Code Type A UPC EAN B Code 39 Code 39 Full ASCII Code 32 C Codabar D...

Page 164: ...Type Option Value Option Code 39 0 No check character or Full ASCII processing 1 Reader has checked one check character 3 Reader has checked and stripped check character 4 Reader has performed Full A...

Page 165: ...t 4123 is transmitted as F04123 Code 93 0 No options specified at this time Always transmit 0 Example A Code 93 bar code 012345678905 is transmitted as G0012345678905 MSI 0 Check digits are sent 1 No...

Page 166: ...e Always transmit 0 DataBar Omnidi rectional RSS 14 and DataBar Limited transmit with an Applica tion Identifier 01 Note In UCC EAN 128 emulation mode DataBar is transmitted using Code 128 rules i e C...

Page 167: ...es The sample bar codes in this appendix are typical representations for their symbology types UPC EAN UPC A 100 EAN 13 100 Code 128 0 12345 67890 5 3 456789 012340 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8...

Page 168: ...162 QuickScan L Sample Bar Codes continued Code 39 Code 93 Code 11 Interleaved 2 of 5 123ABC 123456 9 123456 1234567890...

Page 169: ...Discrete 2 of 5 DTF Product Reference Guide 163 Discrete 2 of 5 DTF Chinese 2 of 5 Codabar MSI 1 2 3 2 4 6 5 7 12345678902 A13579B 24681355...

Page 170: ...ow see GS1 DataBar RSS on page 140 10293847560192837465019283746029478450366523 DataBar Expanded Stacked 1234890hjio9900mnb DataBar Expanded 08672345650916 DataBar Limited 55432198673467 DataBar Omnid...

Page 171: ...Product Reference Guide 165 Appendix E Keypad Use the bar codes in this appendix to enter numbers as you would select digits characters from a keypad 0 1 2 3 4 5...

Page 172: ...166 QuickScan L Cancel To correct an error or change a selection scan the bar code below 6 7 8 9 Cancel...

Page 173: ...Keystroke 1000 U CTRL 2 1001 A CTRL A 1002 B CTRL B 1003 C CTRL C 1004 D CTRL D 1005 E CTRL E 1006 F CTRL F 1007 G CTRL G 1008 H CTRL H BACKSPACE1 1009 I CTRL I HORIZONTAL TAB1 1010 J CTRL J 1011 K C...

Page 174: ...L 1029 C CTRL 1030 D CTRL 6 1031 E CTRL 1032 Space Space 1033 A 1034 B 1035 C 1036 D 1037 E 1038 F 1039 G 1040 H 1041 I 1042 J 1043 K 1044 L 1045 1046 1047 o 1048 0 0 1049 1 1 1050 2 2 1051 3 3 Table...

Page 175: ...0 G 1061 H 1062 I 1063 J 1064 V 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P 1081 Q Q Table 34 ASCII...

Page 176: ...Z 1091 K 1092 L 1093 M 1094 N 1095 O _ 1096 W 1097 A a 1098 B b 1099 C c 1100 D d 1101 E e 1102 F f 1103 G g 1104 H h 1105 I i 1106 J j 1107 K k 1108 L l 1109 M m 1110 N n 1111 O o Table 34 ASCII Valu...

Page 177: ...old is sent only if the Function Key Mapping is enabled Otherwise the unbolded keystroke is sent Table 35 ALT Key Standard Defaults ALT Keys Keystroke 2064 ALT 2 2065 ALT A 2066 ALT B 2067 ALT C 2068...

Page 178: ...2083 ALT S 2084 ALT T 2085 ALT U 2086 ALT V 2087 ALT W 2088 ALT X 2089 ALT Y 2090 ALT Z Table 36 Miscellaneous Key Standard Defaults Misc Key Keystroke 3001 PA 1 3002 PA 2 3003 CMD 1 3004 CMD 2 3005...

Page 179: ...space bar Windows based systems have a GUI key to the left of the left ALT key and to the right of the right ALT key Other Value Keystroke 3048 GUI 0 3049 GUI 1 3050 GUI 2 3051 GUI 3 3052 GUI 4 3053...

Page 180: ...GUI Y 3090 GUI Z Table 38 PF Key Standard Default Table PF Keys Keystroke 4001 PF 1 4002 PF 2 4003 PF 3 4004 PF 4 4005 PF 5 4006 PF 6 4007 PF 7 Table 37 GUI Shift Keys Continued GUI Shift Keys The Ap...

Page 181: ...F 15 4016 PF 16 Table 39 F key Standard Default Table F Keys Keystroke 5001 F 1 5002 F 2 5003 F 3 5004 F 4 5005 F 5 5006 F 6 5007 F 7 5008 F 8 5009 F 9 5010 F 10 5011 F 11 5012 F 12 5013 F 13 5014 F 1...

Page 182: ...24 Table 40 Numeric Key Standard Default Table Numeric Keypad Keystroke 6042 6043 6044 Undefined 6045 6046 6047 6048 0 6049 1 6050 2 6051 3 6052 4 6053 5 6054 6 6055 7 6056 8 6057 9 6058 Enter 6059 N...

Page 183: ...ult Table Extended Keypad Keystroke 7001 Break 7002 Delete 7003 Pg Up 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 7014 Es...

Page 184: ...178 QuickScan L NOTES...

Page 185: ...hes to indicate the disabled status This state is cleared if 1 an Enable Command is sent 2 a Reset Command is sent 3 power is cycled to the scanner Enable Scanner Command ASCII E places the scanner in...

Page 186: ...180 QuickScan L NOTES...

Page 187: ...ions 48 RTS line state 46 stop bit select 39 RS 232 parameters parity 38 symbologies bi directional redundancy 145 bookland EAN enable disable 101 Chinese 2 of 5 enable disable 132 codabar CLSI editin...

Page 188: ...t 105 UPC E1 preamble 108 UPC E1 transmit check digit 105 UPC E1 enable disable 100 USB caps lock override 80 country keyboard types 78 device type 77 keystroke delay 80 unknown characters 81 bar code...

Page 189: ...ns 147 R RS 232 connection 32 RS 232 defaults 33 RS 232 parameters 33 RSS bar codes reduced space symbology 140 S sample bar codes code 128 161 code 39 162 interleaved 2 of 5 162 UPC EAN 161 scanning...

Page 190: ...184 QuickScan L...

Page 191: ......

Page 192: ...Datalogic Scanning KK Telephone 81 0 3 3491 6761 japan scanning datalogic com Latin America Datalogic Scanning Inc Telephone 305 591 3222 latinamerica scanning datalogic com Singapore Datalogic Scann...

Reviews: