1D Symbologies
Enter/Exit Programming Mode
Product Reference Guide
167
Code 93 Set Length 1
Specifies one of the bar code lengths for
Code 93 Length Control on page 166
. Length 1 is the
minimum label length if in
Mode, or the first fixed length if in
Mode. Length includes the bar code’s data characters only. The
length can be set from 01 to 50 characters.
provides some examples for setting Length 1. See
for detailed instructions
on setting this feature.
Table 19. Code 93 Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
01 Characters
07 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 93 LENGTH 1 SETTING
4
Scan Two Characters From
‘0’ and ‘1’
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
5
Scan ENTER/EXIT PROGRAMMING MODE
$CC9L1
Select Code 93 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save
the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT
01 = Length 1 is 1 Character