Enter/Exit Programming Mode
198
QuickScan™ I QD24XX/QBT24XX/QM24XX
Micro PDF417 Length Control
This feature specifies either variable length decoding or fixed length decoding for this symbol-
ogy.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
DEFAULT
$CMILC00(CR)
Micro PDF417 Length Control = Variable Length
$CMILC01(CR)
Micro PDF417 Length Control = Fixed Length
Micro PDF417 Set Length 1
Specifies one of the bar code lengths for
Micro PDF417 Length Control on page 198
. Length 1 is
the minimum label length if in
Variable Length
Mode, or the first fixed length if in Fixed Length
Mode. Length includes the bar code’s data characters only. Characters can be set from 0001 to
0366 characters (pad with zeroes) in increments of 01. Any value greater than 0366 will be
considered to be 0366.
See
for detailed instructions on setting this feature.
$CMIL1
Select Micro PDF417 Length 1 Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at left followed by the digits from the Alphanumeric
characters in
representing
your desired character(s). End by scanning the ENTER/
EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
0001 = Length 1 is 1 Character
Summary of Contents for QuickScan QBT24 series
Page 188: ...Enter Exit Programming Mode Plessey 178 QuickScan I QD24XX QBT24XX QM24XX NOTES...
Page 220: ...Symbology Selection 210 QuickScan I QD24XX QBT24XX QM24XX NOTES...
Page 302: ...Keypad 292 QuickScan I QD24XX QBT24XX QM24XX A B C D E F...