RS-232 Parameters
Product Reference Guide
239
Enable Character
Specifies the value of the RS-232 host command used to enable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts
with normal operation of these characters. 8-bit data is not recognized when the option
has been set as 7 Data Bits.
To set this feature:
Determine the desired character or value.
A setting of 0xFF indicates the Enable Character is
not used (not available).
1. Determine the desired character or value.
2. Use the
on the inside back cover of this manual to find the hex equivalent for
the desired character/value.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode.
4. Scan the bar code: SELECT ENABLE CHARACTER SETTING.
5. Scan the appropriate two alphanumeric characters from the keypad in
, that represent the desired character/value in step 2 above. The second character will
cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See
for some examples of how to set this feature.
Table 31. Enable Character Setting Examples
STEP
ACTION
EXAMPLES
1
Desired character/value
‘e’
‘}’
‘E’
Enable Command
Not Used
2
Hex equivalent from
0x65
0x7D
0x45
0xFF
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT ENABLE CHARACTER VALUE SETTING
5
Scan Two Characters From
‘6’ and ‘5’
‘7’ and ‘D’
‘4’ and ‘5’
‘F’ AND ‘F’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for QuickScan QBT24 series
Page 188: ...Enter Exit Programming Mode Plessey 178 QuickScan I QD24XX QBT24XX QM24XX NOTES...
Page 220: ...Symbology Selection 210 QuickScan I QD24XX QBT24XX QM24XX NOTES...
Page 302: ...Keypad 292 QuickScan I QD24XX QBT24XX QM24XX A B C D E F...
Page 312: ...Scancode Tables 302 QuickScan I QD24XX QBT24XX QM24XX NOTES...