RF Features
Product Reference Guide
263
STAR Radio Protocol Timeout
This parameter sets the valid wait time before transmission between the handheld reader and
Base Station is considered failed.
When setting this parameter, take into consideration the radio traffic (number of readers in the
same area). The selectable range for this feature is from 02 to 25 seconds.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield two digits. For example: 2 = 02, 5 = 05, 25 =
25, etc
3. Go to
and scanScan the ENTER/EXIT PROGRAMMING MODE barcode to enter Pro-
gramming Mode.
4. Scan the barcode: SELECT RADIO PROTOCOL TIMEOUT.
5. Scan the appropriate two digits from the keypad in
, that represent the
duration which was determined in the steps above. You will hear a two-beep indication
after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not
save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See
Table 46
for some examples of how to set this feature.
Table 46. STAR Radio Protocol Timeout Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
2 Seconds
5 Seconds
10 Seconds
25 Seconds
2
Pad with leading zero(es)
02
05
10
25
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECTSTAR RADIO PROTOCOL TIMEOUT SETTING
5
Scan Two Characters From
‘0’ and ‘2’
‘0’ and ‘5’
‘1’ and ‘0’
‘2’ AND ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for QuickScan QBT24 series
Page 188: ...Enter Exit Programming Mode Plessey 178 QuickScan I QD24XX QBT24XX QM24XX NOTES...
Page 220: ...Symbology Selection 210 QuickScan I QD24XX QBT24XX QM24XX NOTES...
Page 302: ...Keypad 292 QuickScan I QD24XX QBT24XX QM24XX A B C D E F...
Page 312: ...Scancode Tables 302 QuickScan I QD24XX QBT24XX QM24XX NOTES...