background image

Warranty

32

   QUICKSCAN™ QD2590

WARRANTY

Datalogic warrants that the Products shall be free from defects in materials
and workmanship under normal and proper use during the Warranty
Period. Products are sold on the basis of specifications applicable at the
time of manufacture and Datalogic has no obligation to modify or update
Products once sold. The Warranty Period shall be 

five years

 from the date

of shipment by Datalogic, unless otherwise agreed in an applicable writing
by Datalogic.
Datalogic will not be liable under the warranty if the Product has been
exposed or subjected to any: (1) maintenance, repair, installation, han-
dling, packaging, transportation, storage, operation or use that is improper
or otherwise not in compliance with Datalogic’s instruction; (2) Product
alteration, modification or repair by anyone other than Datalogic or those
specifically authorized by Datalogic; (3) accident, contamination, foreign
object damage, abuse, neglect or negligence after shipment to Buyer; (4)
damage caused by failure of a Datalogic-supplied product not under war-
ranty or by any hardware or software not supplied by Datalogic; (5)any
device on which the warranty void seal has been altered, tampered with,
or  is  missing;  (6)  any  defect  or  damage caused by natural or man-made
disaster such as but not limited to fire, water damage, floods, other natural
disasters, vandalism or abusive events that would cause internal and exter-
nal component damage or destruction of the whole unit, consumable
items; (7) use of counterfeit or replacement parts that are neither manu-
factured nor approved by Datalogic for use in Datalogic-manufactured
Products; (8) any damage or malfunctioning caused by non-restoring action
as for example firmware or software upgrades, software or hardware
reconfigurations etc.; (9) loss of data; (10) any consumable or equivalent
(e.g. cables, power supply, batteries, etc.); or (11) any device on which the
serial number is missing or not recognizable.

THE DATALOGIC WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER
WARRANTIES, WHETHER WRITTEN, EXPRESS, IMPLIED, STATUTORY OR
OTHERWISE, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE. DATA-
LOGIC SHALL NOT BE LIABLE FOR ANY DAMAGES SUSTAINED BY BUYER
ARISING FROM DELAYS IN THE REPLACEMENT OR REPAIR OF PRODUCTS
UNDER THE ABOVE. THE REMEDY SET FORTH IN THE WARRANTY STATE-
MENT IS THE BUYER’S SOLE AND EXCLUSIVE REMEDY FOR WARRANTY
CLAIMS. NO EXTENSION OF THIS WARRANTY WILL BE BINDING UPON DAT-
ALOGIC UNLESS SET FORTH IN WRITING AND SIGNED BY DATALOGIC'S
AUTHORIZED REPRESENTATIVE. DATALOGIC'S LIABILITY FOR DAMAGES ON
ACCOUNT OF A CLAIMED DEFECT IN ANY PRODUCT DELIVERED BY DATA-
LOGIC SHALL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCT
ON WHICH THE CLAIM IS BASED. DATALOGIC SHALL NOT BE LIABLE FOR
DAMAGES RELATING TO ANY INSTRUMENT, EQUIPMENT, OR APPARATUS
WITH WHICH THE PRODUCT SOLD UNDER THIS AGREEMENT IS USED. 

Fur-

ther details on warranty coverage, rights and conditions are addressed
under and regulated by the Terms and Conditions of Sales of Datalogic
available at https://www.datalogic.com/terms_conditions_sales.

Summary of Contents for QuickScan QD2590

Page 1: ...QuickScan QD2590 QUICK REFERENCE GUIDE General Purpose Corded Handheld Area Imager Bar Code Reader...

Page 2: ...y be downloaded from the Data logic website www datalogic com If you visit our website and would like to make comments or suggestions about this or other Datalogic publica tions please let us know via...

Page 3: ...System Pattern on 2D Matrix Symbol 6 Relative Size and Location of Aiming System Pattern on Linear bar code 7 Relative Size and Location of Green Spot 7 Parts of the Reader 8 Selecting the Interface T...

Page 4: ...26 LED and Beeper Indications 30 Troubleshooting 31 Warranty 32 Ergonomic Recommendations 33 Cleaning Procedure 34 Common Cleaning Solutions 34 Cleaning enclosure and window surfaces 34 Technical Sup...

Page 5: ...which it is intended for use in machine readable form only solely for End User s internal business purposes 1 2 End Users shall not distribute sublicense rent loan lease assign export re export resel...

Page 6: ...any time Subject to the foregoing termination shall be effective upon notice to the other party In the event that this Agreement terminates for any rea son End User s license to use the Software will...

Page 7: ...software hardware systems or other items not provided by Datalogic 7 Support End User may request support for Software from Datalogic at Datalogic s standard support fees and under Datalogic s standa...

Page 8: ...ed in its native language form without modification or translation Please reference and review the above mentioned information to identify which Open Source Software packages have source code provided...

Page 9: ...ty shall be entitled to reasonable attorneys fees both at trial and on appeal For Asia Pacific Countries The validity interpretation and construction of the Agreement shall be governed by and construe...

Page 10: ...customers with the very latest in Datalogic soft ware technology The only exception to this policy is when the buyer has a signed contract with Datalogic that clearly defines the terms and conditions...

Page 11: ...m developed with the unique intent to reduce visual stress of the operator during the daily scanning activities The outstanding aimer consists of two blue LED triangles pointing at the targeted bar co...

Page 12: ...nside the field of view and switch the reading system from trigger mode to auto sense mode Decoding The QuickScan QD2590 reliably decodes all standard 1D linear and 2D bar codes including GS1 DataBar...

Page 13: ...with integrated stand at a convenient angle allow ing hands free scanning of items It can also be used as a holder The holder cup can be positioned in any of the three angles shown in the figure belo...

Page 14: ...below to connect and get your reader up and communicating with its host 1 Connect the Cable to the reader and the Host as shown below 2 Configure the Interface see page 9 3 Program the Reader starting...

Page 15: ...take a paper clip and modify it as shown in the figure below Insert the end of the paper clip into the hole and press it to push on the clip that holds the connector As you apply pressure pull out th...

Page 16: ...decoding codes The reader is equipped with an inter nal Motionix motion sensing function which activates the aiming system on device motion The intelligent aim ing system indicates the field of view w...

Page 17: ...aller bars or ele ments mil size should be read closer to the unit Symbologies with larger bars or elements mil size should be read farther from the unit If the aiming system is centered and the entir...

Page 18: ...ur application For interfaces other than those listed in this manual see the QuickScan QD2590 Product Reference Guide PRG available online at www datalogic com Interface Selection The reader will supp...

Page 19: ...Unlike some other programming fea tures and options interface selections require that you scan only one programming bar code label DO NOT scan an ENTER EXIT bar code prior to scanning an interface se...

Page 20: ...standard interface Select RS232 STD RS 232 Wincor Nixdorf Select RS232 WN RS 232 for use with OPOS UPOS JavaPOS Select RS 232 OPOS USB Com to simulate RS 232 standard interface Select USB COM STD1 1...

Page 21: ...uring the Interface QUICK REFERENCE GUIDE 11 USB OEM USB OEM can be used for OPOS UPOS JavaPOS Select USB OEM USB COMPOSITE USB Composite Select USB Composite IBM46XX IBM46xx Port 9b Select IBM46xx Po...

Page 22: ...figuring the Interface 12 QUICKSCAN QD2590 USB FOR TERMINALS USB HID POS Select USB HID POS USB Toshiba TEC Select USB Toshiba TEC USB FOR MAGELLAN SCANNERS USB for Magellans Select USB Magellan Scann...

Page 23: ...AT PS 2 25 286 50 50Z 60 70 80 90 95 w Standard Key Encoding Select KBD AT Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard Select KBD AT NK AT PS 2 25 286 30 286...

Page 24: ...with alternate key encoding USB Keyboard with standard key encoding AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Std Key Encoding Keyboard Wedge for IBM AT PS2 with standard key encoding but without...

Page 25: ...lowing Country Modes U S Belgium Britain France Germany Italy Spain Sweden Default value Supports only the interfaces listed in the Country Mode feature description COUNTRY MODE ENTER EXIT PROGRAMMING...

Page 26: ...QD2590 Supports only the interfaces listed in the Country Mode feature description COUNTRY MODE CONTINUED Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Co...

Page 27: ...UIDE 17 Supports only the interfaces listed in the Country Mode feature description COUNTRY MODE CONTINUED Country Mode Japanese 106 Key Country Mode Lithuanian Country Mode Norway Country Mode Poland...

Page 28: ...the interface bar code from the Interfaces section select other options and cus tomize your reader through use of the programming bar codes available in the QuickScan QD2590 PRG Check the correspondin...

Page 29: ...n Configure Other Settings Additional programming bar codes are available in the PRG to allow for customizing programming features If your installation requires different programming than the standard...

Page 30: ...ing of the Numbers Lock Numlock key while in keyboard wedge interface This only applies to alternate key encoding interfaces It does not apply to USB keyboard Default value NUMLOCK ENTER EXIT PROGRAMM...

Page 31: ...alternate key encoding key board is selected Default value READING PARAMETERS Move the reader toward the target and center the aiming pattern and illumination system to capture and decode the image Se...

Page 32: ...you are holding the reader Aiming System A number of options for customizing control of the Aiming System are available See the QuickScan QD2590 PRG for more information and programming bar codes GOOD...

Page 33: ...an on time 1 has elapsed Reading a label does not disable scanning Double Read Timeout1 pre vents undesired multiple reads while in this mode Trigger Hold Multiple When the trigger is pulled scanning...

Page 34: ...g area If a predefined amount of movement is detected the white illumination switches on Scanning continues until a label is read or maximum scan on time is reached Default value SCAN MODE ENTER EXIT...

Page 35: ...owledged or transmit ted to the host It is active only while the scanner is in Trig ger Single mode If the scanner switches to a different Read Mode Pick Mode is automatically disabled Default value M...

Page 36: ...VDC 5 Consumption Operating Typical 450 mA 5V Standby Idle Typical 90 mA 5V Max Scan Rate 60 frames sec Reading Indicators Top illumination Good Read Spot Beep ENVIRONMENTAL FEATURES Operating Tem pe...

Page 37: ...x 2453 um V Active Pixels 1280 H x 800 V Illumination System LED source Red Emission wavelength 617 nm Aiming System LED source Blue Emission wavelength 470nm Ambient Light Up to 100 000 lux Tilt Tol...

Page 38: ...tion 10 2 The values are obtained with the item DOF Enhancement enabled Symbology DOF range Code 39 5 mil 0 5 25 0 cm 0 19 9 8 10 mil 0 5 38 cm 0 19 14 9 EAN13 13 mil 0 5 41 0 cm 0 19 16 1 PDF417 6 7...

Page 39: ...d Codes The QuickScan QD2590 scanner is capable of decoding the following symbolo gies using multiple frames i e Multi Frame Decoding Datamatrix Inverse Datamatrix Datamatrix is configurable for the f...

Page 40: ...LED blinks until enumeration with the host is completed Imager beeps four times at highest frequency and volume upon power up Good Read Upper green LED comes on for programmed time default LED behavi...

Page 41: ...ode type Ensure imager is programmed to read the type of bar code scanned Refer to the PRG for more information Bar code label is unreadable Check the label to ensure it is not defaced Try scanning an...

Page 42: ...le unit consumable items 7 use of counterfeit or replacement parts that are neither manu factured nor approved by Datalogic for use in Datalogic manufactured Products 8 any damage or malfunctioning ca...

Page 43: ...orrect heights Reduce or eliminate vibration Reduce or eliminate direct pressure Provide adjustable workstations Provide adequate clearance Provide a suitable working environment Improve work procedur...

Page 44: ...a recommended cleaning solution Be sure to apply the solution to your cloth first Wring excessive liquid from the cloth CAUTION Do not use abrasive pads or cleaning agents CAUTION Be sure to turn off...

Page 45: ...website Log on to www datalogic com For quick access from the home page click on the search icon and type in the name of the product you re looking for This allows you access to download Data Sheets M...

Page 46: ......

Page 47: ......

Page 48: ...ted in any form or by any means or for any purpose without the express written permission of Datalogic S p A and or its affiliates Datalogic and the Datalogic logo are registered trademarks of Datalog...

Reviews: