16 STS320
CHAPTER 4
SOFTWARE CONFIGURATION
There are two main methods that can be used to complete the STS320 installation.
The first regards stations that do not need any application specific parameter configura-
tion. The factory default configuration is sufficient and the only necessary steps are to
align the Master IP Address to the Host LAN through a web browser using the Web Dis-
covery feature, then backup the configuration through the CBX500 menu.
The second method requires installation of the DL.CODE configuration program.
Through DL.CODE, IP Addresses are aligned, application specific parameters are config-
ured, and backup procedures are performed both to the external storage device
(BM100), as well as to a file.
STS320 DEFAULT CONFIGURATION
Default IP Address
192.168.3.100
Code symbologies
CODE128, CODE39, INT2OF5 (min. 8 digits)
Layout type
Synchronized
Operating mode
Phase mode
Phase ON: Input 1 - Leading Edge
Phase OFF: Input 2 - Trailing Edge
Acquisition trigger
Periodic (25 ms)
Data collection type
Code combination (1 expected code)
Output
•
Good Read: Output 2, Green Spot, 360° Green Feedback
•
No Read: Output 1, Red Spot, 360° Red Feedback
•
Configuration Mode: 360° Blue Feedback
Output Message 1
Event Type: Good Read, Output Channel: TCP Server (port 51236),
Message content: <STX><CodeContent><CR><LF>
Output Message 2
Event Type: No Read, Output Channel, TCP Server (port 51236),
Message content: <STX><CAN><CR><LF>
CONFIGURATION USING WEB DISCOVERY